§ 31-15 — Cross connection protection requirements
Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana City Code § 31-15
Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/467406a2-7110-42cd-8eb7-3552b2bfc77b
Sec. 31-15. - Cross connection protection requirements.
(a) It shall be unlawful install unprotected cross connections with the public water supply system. (b) Whenever backflow protection has been found necessary, the city may require the water user to install an approved backflow prevention assembly by and at his expense for continued services or before a new services is granted. (c) Wherever backflow protection has been found necessary on a water supply line entering a water user's premises, then any and all water supply lines from the city's main user's premises, then any and all water supply lines from the city's mains entering such premises, buildings, or structures shall be protected by an approved backflow prevention assembly. The type of assembly to be installed will be in accordance with the requirements of this Code. (d) Each service connection from the city water system for supplying water to premises which have an auxiliary water supply shall be protected against backflow of water from the premises into the public water system unless the auxiliary water supply is accepted as an additional source by the city, and is approved by the public health agency having jurisdiction. (e) Each service connection from the city water system for supplying water to any premises on which any substance is handled in such fashion as may allow its entry into the water system shall be protected against backflow of the water from the premises into the public system. This shall include the handling of process waters and waters originating from the city water system which have been subjected to deterioration in sanitary quality. (f) Backflow prevention assemblies shall be installed on the service connection to any premises having (1) internal cross connections that cannot be permanently corrected and controlled to the satisfaction of the state or local health department and the city, or (2) intricate portions of the premises not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not cross connections exist. (g) The type of protection that shall be provided to prevent backflow into the approved water supply shall be commensurate with the degree of hazard that exists on the consumer's premises. The type of protective assembly that may be required (listing in an increasing level of protection) includes: Double check valve assembly (DC), reduced air pressure principle backflow prevention assembly (RP), and an air gap separation (AG). The water user may choose a higher level of protection than required by the city. The minimum types of backflow protection required to protect the approved water supply, at the user's water connection to premises with varying degrees of hazard are given in Table 1. Situations which are not covered in Table 1 shall be evaluated on a case by case basis and the appropriate backflow protection shall be determined by the City of Fontana or the health agency. Table 1. Type of Backflow Protection Required Degree of Hazard | Minimum Type of Back Flow Prevention A. | Sewage and Hazardous Substances (1) Premises where the public water system is used to supplement the reclaimed water supply. | AG (2) Premises where there are waste water pumping and/or treatment plants and there is no interconnection with the potable water system. This does not include a single family residence that has a sewage lift pump. A RP may be provided in lieu of an AG if approved by the health agency and the City of Fontana. | AG (3) Premises where reclaimed water is used and there is no interconnection with the potable water system. An RP may be provided in lieu of an AG if approved by the health agency and the City of Fontana. | AG (4) Premises where hazardous substances are handled in an manner in which the substances may enter a potable water system. This does not include a single family residence that has a sewage pump. An RP may be provided in lieu of an AG if approved by the health agency and the City of Fontana. | AG (5) Premises where there are irrigation systems into which fertilizers, herbicides, or pesticides are, or can be, injected. | RP B. | Auxiliary Water Supplies (1) Premises where there is an unapproved auxiliary water supply which is interconnected with the public water system. An RP or DC may be provided in lieu of an AG if approved by the health agency and the City of Fontana. | AG (2) Premises where there is an unapproved auxiliary water supply and there are no interconnections with the public water system. A DC may be provided in lieu of an RP if approved by the health agency and the City of Fontana. | RP C. | Fire Protection Systems (1) Premises where the fire system is directly supplied from the public water system and there is an unapproved auxiliary water supply on or to the premises (not interconnected). | DC (2) Premises where the fire system is supplied from the public water system and interconnected with an unapproved auxiliary water supply. An RP may be provided in lieu of an AG if approved by the health agency and the City of Fontana. | AG (3) Premises where the fire system is supplied from the public water system and where either elevated storage tanks or fire pumps which take suction from the private reservoirs or tanks are used. | DC D. | Premises where entry is restricted so that inspections for cross connections cannot be made with sufficient frequency or at sufficiently short notice to assure that cross connections do not exist. | RP E. | Premises where there is a repeated history of cross connections being established or re-established. | RP (h) Two or more services supplying water from different mains to the same building, structure, or premises through which an interstreet main flow may occur, shall have at least a standard check valve on each water service to be located adjacent to and on the property side of the respective meters. Such check valve shall not be considered adequate if backflow protection is deemed necessary to protect the city's mains from pollution or contaminations; in such cases the installation of approved backflow assemblies as such service connections shall be required.
(Ord. No. 1195, § 1, 8-6-96)
Ask a question about Fontana law
Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.