§ 31-16 — Backflow prevention assemblies
Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana City Code § 31-16
Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/d67a8b75-a4d4-4003-9fea-a3b22bc1d12e
Sec. 31-16. - Backflow prevention assemblies.
(a) Only backflow prevention assemblies which have been approved by the city shall be acceptable for installation by a water user connected to the city's public water system. (b) The city may provide, upon request, to any affected water user a list of approved backflow prevention assemblies. (c) The listing of approved devices shall be those listed on approved devises as set by the State of California Department of Health Services. (d) Backflow prevention assemblies shall be installed in a manner prescribed in Section 7603 of Title 22 of the California Code of Regulations. The location of the assemblies should be close as practical to the water user's connection. The city shall have the final authority in determining the required location of a backflow prevention assembly. (e) Air gap separation (AG). The air gap separation shall be located on the water user's side of and shall be as close to the service connection as is practical. All piping from the service connection to the receiving tanks shall be above grade and be entirely visible. No water use shall be provided from any point between the service connection and the air gap separation. The water inlet piping shall terminate at a distance of at least two pipe diameters of the supply inlet, but in no case less than one inch above the overflow rim of the receiving tank. (f) Reduced pressure principle backflow prevention assembly (RP). The approved reduced pressure principle backflow prevention assembly shall be installed on the user's side of and as close to the service connection as is practical. The assembly shall be installed at a minimum of 12 inches above grade and not more than 36 inches above grade measured from the bottom of the assembly and with a minimum of 12 inches side clearance. The assembly shall be installed so that it is readily accessible for maintenance and testing. Water supplied from any point between the service connection and the RP assembly shall be protected in a manner approved by the City of Fontana. (g) Double check valve assembly (DC). The approved double check valve assembly shall be located as close as practical to the water user's connection and shall be installed above grade, if possible, and in a manner where it is readily accessible for testing and maintenance. If a double check valve assembly is put below grade it must be installed in a vault such that there is a minimum of six inches between the bottom of the vault and the bottom of the assembly, so that the top of the assembly is no more than a maximum of eight inches below grade, so there is a minimum of 24 inches of clearance between the side of the assembly with the test cocks and the side of the vault. Special consideration must be given to double check valve assemblies of the "Y" type. These assemblies must be installed on their "side" with the test cock in a vertical position so that either check valve may be removed for service without removing the assembly. Vaults which do not have an integrated bottom must be placed on a three inch layer of gravel. (h) The owners of any premises on which, or on account of which, backflow prevention assemblies are installed, shall have the assemblies tested by a person who has demonstrated their competency in testing of these assemblies to the city. Backflow prevention assemblies must be tested at least annually and immediately after installation, relocation or repair. The city may require a more frequent testing schedule if it is determined to be necessary. No assembly shall be placed back in service unless it is functioning as required. A report in a form acceptable to the city shall be filed with the city each time an assembly is tested, relocated, or repaired. These assemblies shall be serviced, overhauled, or replaced whenever they are found to be defective and all cost of testing, repair, and maintenance shall be borne by the water user. (i) The city may supply affected water users with a list of persons acceptable to the city to test backflow prevention assemblies. The city may notify affected customers by mail when annual testing of an assembly is needed and also supply water users with the necessary forms which must be filled out each time an assembly is tested or repaired. (j) Upon request, the city may test a water user's backflow prevention assembly to fulfill the requirements of this article. The water user shall pay for the test and any maintenance found necessary to keep the assembly in working order on the next regular water billing and/or letter billing. (k) Approval must be obtained from the City of Fontana before a backflow prevention assembly is removed, relocated, or replaced in accordance with the following: (1) Removal: The use of an assembly may be discontinued and the assembly removed from service upon presentation of sufficient evidence to the city to verify that a hazard no longer exists or is not likely to be created in the future. (2) Relocation: An assembly may be relocated following confirmation by the city that the relocation will continue to provide the required protection and satisfy installation requirements. A retest will be required following the relocation of the assembly. (3) Repair: An assembly may be removed for repair, provided the water use is either discontinued until repair is complete and the assembly is returned to service, or the service connection is equipped with other backflow protection approved by the city. A retest will be required following the repair of the assembly. (4) Replacement: An assembly may be removed and replaced provided the water use is discontinued until the replacement assembly is installed. All replacement assemblies must be approved by the city and must be commensurate with the degree of hazard involved.
(Ord. No. 1195, § 1, 8-6-96)
Ask a question about Fontana law
Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.