§ 13.32.060: Type of protection required.

A. The type of protective device that may be required to prevent backflow into the approved water supply (listing in an increasing level of protection) includes: double check valve assembly (DC), reduced pressure principle backflow prevention assembly (RP), and an air-gap separation (AG). The customer may choose a higher level protection than required by the division. B. The minimum types of backflow protection that shall be installed on customer's premises at the service connection whenever the following degrees of hazard exist are as follows: Degree of Hazard | Prevention | Minimum Type of Backflow Prevention 1. Sewage and Hazardous Substances. a. | A system where the city water system is used to supplement a recycled water supply. If an emergency exists where potable water is connected to a recycled water system, potable water system shall be isolated by an air-gap separation as determined by the assistant general manager and the health agency. An approved backflow prevention assembly shall be installed on the potable water line. | AG b. | A system where there are wastewater pumping and/or treatment plants and there is no interconnection (but the potential exists) with the city water system. This includes multifamily buildings, but not a single-family residence, that has a sewage lift pump. A reduced pressure principle backflow prevention assembly may be provided in lieu of an air-gap if approved by the assistant general manager and the health agency. | AG c. | A system where recycled water is used and there is no interconnection (but the potential exists) with the potable water system. A reduced pressure principle backflow prevention assembly may be provided in lieu of an air-gap if approved by the assistant general manager and the health agency. | AG d. | A system where hazardous substances are handled such as to create an actual or potential hazard to the city water system. This shall include systems having auxiliary water supplies, tanks or industrial piping systems containing process fluids or used waters originating from the city water system which are no longer under the sanitary control of the city. This, however, does not include a single-family residence that has a sewage lift pump. A reduced pressure principle backflow prevention assembly may be provided in lieu of an air-gap if approved by the assistant general manager and the health agency. | AG e. | A system where there are irrigation systems into which fertilizers, herbicides or pesticides are, or can be, injected. | RP 2. Auxiliary Water Supplies. a. | A system where there is an unapproved auxiliary water supply which is interconnected with the public water system. A reduced pressure principle backflow prevention assembly may be provided in lieu of an air-gap if approved by the assistant general manager and the health agency. | AG b. | A system where there is an unapproved auxiliary water supply and there are no interconnections with tire public water system. A double check valve assembly may be provided in lieu of a reduced pressure principle backflow prevention assembly if approved by the assistant general manager and the health agency. | RP 3. Fire Protection Systems. All fire protection systems will be required to have backflow prevention devices as described below. However, Class I and Class II fire protection systems will be exempt from these requirements. Class I and Class II fire protection systems are defined under Section 13114.7 of the California Health and Safety Code (Refer to AWWA Manual M-14). a. | A fire system that is directly supplied or from the public water system and an unapproved auxiliary water supply is available for use on or to the premises (not interconnected). A double check valve assembly may be provided in lieu of a reduced pressure principle backflow prevention assembly if approved by the assistant general manager and the health agency. | RP reduced pressure detector check assembly b. | A fire system that is supplied from the public water system and interconnected with an unapproved auxiliary water supply. A reduced pressure principle backflow prevention assembly may be provided in lieu of an air-gap if approved by the assistant general manager and the health agency. | AG c. | A fire system supplied by the recycled water and the department's water system is used as a supplemental supply. | AG d. | A fire system that is supplied from the department's water system and there exists a recycled water supply to the premises (not interconnected). An RP assembly may be provided in lieu of an AG if approved by the assistant general manager and the health agency. | AG e. | A fire system that is supplied from public water system and where either elevated storage tanks or fire pumps which take suction from the private reservoirs or tanks are used. A double check value assembly may be proved in lieu of a reduced pressure principle backflow prevention assembly if approved by the assistant general manager and the health agency. | RP or reduced pressure detector check assembly f. | A fire system that is interconnected with more than one service connection from the city water system and check no other system hazard exists. | DC or double check detector check assembly 4. Other Systems. a. | A system that requires a booster pump on RP the service connection line. (For fire service requirements, refer to subsection (B)(3)(e) of this section.) | RP b. | A system where there are intricate plumbing and piping arrangements or where entry to all portions of the premises is not readily accessible for inspection purposes making it impracticable or impossible to ascertain whether or not cross-connections exist. | RP c. | A system that is restricted, classified or closed to on-site inspection. | RP d | A system where there is a repeated history of cross-connections being established or reestablished within customer's premises. | RP e. | A system with internal cross-connections that cannot be permanently corrected and controlled to the satisfaction of the assistant general manager and the health agency. | RP f. | Two or more services supplying water from different street mains to the same building, assembly, structure or premises through which an interstreet main flow may occur, shall have a double check valve on each water service to be located adjacent to and on the property side of the respective meters. | DC g. | Other systems which may be specified by the department from time to time. | Device to be specified

( Prior code § 9-13 ; Ord. 4980 § 6, 1992 ; Ord. 5112 § 55, 1996 ; Ord. 5678 § 7, 2009 )

Ask a question about Glendale law

Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.