§ 13.32.070: Backflow prevention assemblies.
A. Approved Backflow Prevention Assemblies. Only backflow prevention devices which have been approved by the assistant general manager shall be acceptable for installation by a water user connected to the public water system. B. Backflow Prevention Assembly Installation. 1. The approved backflow assembly shall be installed at the expense of the customer. 2. Air-Gap Separation (AG). The air-gap separation shall be located on the customer's premises as close to the service connection as is practical. All piping from the service connection to the receiving tank shall be above grade and be entirely visible. No water use shall be provided from any point between the service connection and the air-gap separation. The water inlet piping shall terminate a distance of at least two pipe diameters of the supply inlet, but in no case less than one inch above the overflow rim of the receiving tank as specified in the current edition of the Uniform Plumbing Code requirements for minimum air-gaps for water distribution. 3. Reduced Pressure Principle Backflow Prevention Assembly (RP). The approved reduced pressure principle backflow prevention device shall be installed on the customer's premises of and as close to the service connection as is practical. The device shall be installed a minimum of 12 inches above grade and no more than 36 inches above grade measured from the bottom of the device and with a minimum of 12 inches side clearance. The assembly shall be installed so that it is readily accessible for maintenance and testing. Water supplied from any point between the service connection and the RP device shall be protected in a manner approved by the assistant general manager. 4. Double Check Valve Assembly (DC). The approved double check valve assembly shall be located as close as practical to the user's connection and shall be installed horizontally above grade and in a manner where it is readily accessible for testing and maintenance. If it is necessary to put a double check valve assembly below the grade, upon the approval of the assistant general manager and the local health agency, it must be installed in a vault such that there is a minimum of 12 inches between the bottom of the vault and the bottom of the assembly so that the top of the assembly is not more than a maximum of eight inches below grade, so there is a minimum of 24 inches of clearance between the side of the assembly with the test cocks and the side of the vault, and a minimum of 12 inches clearance between the other side of the assembly and the side of the vault. The vault must have adequate drainage to prevent flooding. Special consideration must be given to double check valve assemblies of the "Y" type. These devices must be installed on their "side" with the test cocks in a vertical position so that either check valve may be removed for service without removing the assembly. Vaults which do not have an integrated bottom must be placed on a three-inch layer of gravel. 5. Approved backflow assemblies shall have at least the same cross-sectional area as the water meter. If a continuous water supply is necessary, two sets of approved backflow assemblies shall be installed in parallel. Where parallel assemblies are required, the sum of the cross-sectional areas of the assemblies shall be at least equivalent to the cross-sectional area of the meter. 6. There shall be no outlet, tee, tap or connection of any sort between the water meter and the approved backflow assembly. A "Y" strainer and/or pressure-reducing valve installed before the approved backflow assembly are the only exceptions. 7. Approved backflow assemblies shall not be bypassed, made inoperative or removed without specific written authorization by the assistant general manager. 8. Approved backflow assemblies shall be protected, when necessary, from extreme weather or site condition that could cause physical damage to or malfunction of the backflow assembly. C. Backflow Prevention Device Testing and Maintenance. 1. The owners of any premises on which, or on account of which, backflow prevention assemblies are installed, shall have the assemblies tested by a certified backflow prevention assembly tester licensed by the local health agency. Backflow prevention assemblies must be tested at least annually and immediately after installation, relocation or repair. The department may require a more frequent testing schedule if it is determined to be necessary by the assistant general manager. No device shall be placed back in service unless it is functioning as required. A report in a form acceptable to the city shall be filed with the public service department each time a device is tested, relocated or repaired. These devices shall be serviced, overhauled or replaced whenever they are found to be defective and all costs of testing, repair and maintenance shall be borne by the water user. 2. The department will supply affected water users with a list of certified backflow assembly testers licensed by the local health agency to test backflow prevention assemblies. The department will notify affected customers by mail when annual testing of a device is needed and also supply users with the necessary forms which must be filled out each time a device is tested or repaired. D. Backflow Prevention Assembly Removal. 1. Approval must be obtained from the assistant general manager before a backflow prevention assembly is removed, relocated or replaced. a. Removal. The use of a device may be discontinued and the device removed from service upon presentation of sufficient evidence to the assistant general manager to verify that a hazard no longer exists or is not likely to be created in the future. b. Relocation. An assembly may be relocated following confirmation by the assistant general manager that the relocation will continue to provide the required protection and satisfy installation requirements. A re-test will be required following the relocation of the device. c. Repair. An assembly may be removed for repair, provided the water use is either discontinued until repair is completed and the device is returned to service, or the service connection is equipped with other backflow protection approved by the assistant general manager. A re-test will be required following the repair of the assembly. d. Replacement. An assembly may be removed and replaced provided the water use is discontinued until the replacement assembly is installed. All replacement assemblies must be approved by the assistant general manager and must be commensurate with the degree of hazard involved.
( Prior code § 9136 ; Ord. 4980 § 7, 1992 ; Ord. 5112 § 56, 1996 ; Ord. 5678 § 8, 2009 )
Ask a question about Glendale law
Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.