§ 10-28.3.3.110 — COURTYARD BUILDING

Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 10-28.3.3.110

Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/f0f73bd3-5380-4143-8996-5ddc4a997922

10-28.3.3.110 - COURTYARD BUILDING

[image omitted; see the official code] 3-story Courtyard building with fenced forecourt. [image omitted; see the official code] Stoop entries to units engaging the courtyard. | A. Description One or more structures that contain multiple attached and stacked units, accessed from a courtyard or series of courtyards. Each unit may have its own individual entry, or units may share a common entry. This type is typically integrated sparingly into lower-intensity neighborhoods or more consistently into moderate-intensity neighborhoods and can be applied in non-residential contexts. This type enables appropriately-scaled, well-designed higher densities and is important for providing a broad choice of housing types and promoting walkability. House-Scale Building [image omitted; see the official code] [image omitted; see the official code] 2-story Courtyard building. | General Note: Photos on this page are illustrative, not regulatory. [image omitted; see the official code] [image omitted; see the official code] B. Number of Units Buildings per Lot | 3 max. C. Building Size and Massing NE | NG | UN | DT-MS | UC Max. Number of Stories | — | 3½ | 5 | — | 7 Main Body/Secondary Wing (s) Width | 150' max. | [image omitted; see the official code] Depth | 65' max. | [image omitted; see the official code] Articulation Buildings at least 75' wide are required to: 1. Apply at least one Oriel on front and/or side street facade in compliance with Subsection 3.3.160.A (Oriel). 2. Organize street facing facades in compliance with Subsection 3.3.160.B (Facade Articulation). Accessory Structure(s) No accessory structures are allowed. D. Allowed Frontage Types Porch: Projecting | 3.4.050 Porch: Engaged | 3.4.060 Stoop | 3.4.070 Terrace | 3.4.120 [image omitted; see the official code] E. Pedestrian Access The main entry of ground floor units must be directly off of a courtyard or a street. Courtyards must be accessible from the front property line. | [image omitted; see the official code] Pedestrian connections must link all buildings to the public ROW, courtyards, and parking areas. If multiple courtyards, they must be connected by passages of a maximum width of 12'. F. Courtyard(s) Main Body Height 1 | Width | [image omitted; see the official code] | Depth | [image omitted; see the official code] 1 to 2½ Stories | 20' min.; 40' max. | 20' min.; 75' max. 3 to 3½ Stories | 25' min.; 50' max. | 30' min.; 105' max. 4 to 5 Stories | 25' min.; 60' max. | 40' min.; 135' max. 6 to 7 Stories | 45' min.; 70' max. | 50' min.; 145' max. Buildings must define at least two walls of a courtyard. Side(s) of courtyard not defined by building must be defined by 4' to 6' tall wall with entry gate/door designed to complement the primary structure.

(Amended by Ordinance 24-01, adopted Jan. 23, 2024)

Ask a question about Hayward law

Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.