§ 10-28.3.3.160 — ARCHITECTURAL ELEMENTS
Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 10-28.3.3.160
Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/51967e23-2b6e-44ce-a306-fd52b1d718bb
10-28.3.3.160 - ARCHITECTURAL ELEMENTS
A. Oriel. 1. As required by Subsection C of the zone standards in Division 3.3 (Specific to Building Types), each building must comply with the standards of this Section. 2. Each building may apply more architectural elements than the minimum requirement in compliance with the standards of this Section. a. General Types: Square, Chamfered, and Round (See Subsections F—H) Depth: Depends on oriel type (See Subsections F—H below) Height: At least one story Must not occur below second floor Generally do not have supporting brackets b. Multi-story Horizontal articulation on building, if any, must wrap oriel form. c. Interaction with Cornice Oriel must interact with building's upper cornice in one of the following ways: Cornice wraps oriel; Oriel stops below cornice (oriel has own cornice); or Oriel projects above cornice. d. Standards for Facades > 75' Long Width of Oriel | Varies by type | [image omitted; see the official code] Distance between Oriels | 30' max. | [image omitted; see the official code] [image omitted; see the official code] Contemporary multi-story square oriel [image omitted; see the official code] General Note: Photos on this page are illustrative, not regulatory. [image omitted; see the official code] (above) Square oriels F. Type I: Square Size: Depth | 1' min.; 3' max. Width | 6' min.; 9' max. Widest face of the oriel must accommodate at least 2 windows. Corner oriel may be rotated 45° from building corner. See diagram below. [image omitted; see the official code] [image omitted; see the official code] (Above) Chamfered oriels G. Type II: Chamfered Size: Depth | 1' min.; 3' max. Width | 6' min.; 10' max. Interior angle | 135° to 150° Number of faces per oriel | 3 to 5 Corner oriel may be rotated 45° from building corner. See diagram below. [image omitted; see the official code] [image omitted; see the official code] H. Type III: Round Depth | 1' min.; 3' max. Width | 6' min.; 10' max. Corner oriel circumference may be up to 270°. See diagram below. [image omitted; see the official code] B. Facade Articulation. 1. Applicability. The requirements of this Section apply to new buildings, or facade renovations that are within 50 feet of a street or public open space. 2. Requirements. Facade articulation techniques provided in Table A (Facade Articulation) are required for buildings as follows: a. Subsection B.2.a, all buildings; and b. Subsections B.2.b and B.2.c, at least one item each, as applicable. Table 3.3.160.A Facade Articulation a. All Buildings [image omitted; see the official code] | Tripartite Facade Design. Facades of buildings that are three or more stories shall be designed with tripartite architecture, with a distinct ground floor, middle and top of the building. An expression line, setback or other architectural element shall be used to delineate the base and top. [image omitted; see the official code] | Change in Color or Material. This technique modulates the apparent size and scale of a building by changing colors and/or materials. At least two distinct building materials shall make up at least 25 percent of the total building facades. b. Above the Third Story on All Buildings [image omitted; see the official code] | Architectural Recession(s). This technique modulates the apparent size and scale of a building by recessing a portion(s) of the facade as an architectural element(s) or space(s) from the plane(s): a recessed entry from the sidewalk, a loggia or recessed balcony cut into the plane of the facade. Buildings that exceed 200 linear feet as measured along the back of sidewalk are required to integrate a Forecourt in compliance with Section 3.4.080 (Forecourt). The recession at the ground floor is required to extend through the top of the building. c. Buildings Over 100 Feet Long [image omitted; see the official code] | Horizontal Articulation. This technique modulates the apparent size and scale of the building by stepping a portion of the facade forward or backward from the predominant facade plane by at least three feet forward or backward. This technique may be applied throughout the building but is required above the third story.
(Amended by Ordinance 24-01, adopted Jan. 23, 2024)
Ask a question about Hayward law
Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.
