§ 10-28.3.3.140 — LINED BUILDING
Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 10-28.3.3.140
Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/560a3395-829c-4ef3-ac9b-075b0f09e9a0
10-28.3.3.140 - LINED BUILDING
[image omitted; see the official code] Lined building forms an interesting streetscape along two streets while sharing alley access on the other two sides. [image omitted; see the official code] 2-story office over retail building concealing the interior garage building from the sidewalk. | A. Description A combined building that consists of two main components: an interior building such as a parking garage, movie theater, etc., and an exterior building that conceals the interior building from the street. Block-Scale Building [image omitted; see the official code] [image omitted; see the official code] 5-story housing over office building concealing the garage. | General Note: Photos on this page are illustrative, not regulatory. [image omitted; see the official code] [image omitted; see the official code] B. Number of Units Buildings per Lot | 1 max. 1 1 Exterior Building and Interior Building components of Lined Building count as a single Lined Building. C. Building Size and Massing NE | NG | UN | DT-MS | UC Max. Number of Stories | — | — | 5 | 7 | 7 Exterior Building Main Body Depth | 36' min. | [image omitted; see the official code] Width | 320' max. | [image omitted; see the official code] Length | 420' max. | [image omitted; see the official code] Side of interior building exposed to a street, civic space, or neighboring building must be lined by the exterior building. Interior Building Dimensions for Parking Use Width | 120' min.; 180' max. | [image omitted; see the official code] Depth | 200' min.; 230' max. | [image omitted; see the official code] Articulation Buildings at least 75' wide are required to: 1. Apply at least one Oriel on front and/or side street facade in compliance with Subsection 3.3.160.A (Oriel). 2. Organize street facing facades in compliance with Subsection 3.3.160.B (Facade Articulation). [image omitted; see the official code] D. Allowed Frontage Types Forecourt | 3.4.080 Dooryard | 3.4.090 Stoop | 3.4.070 Shopfront | 3.4.110 Terrace | 3.4.120 Gallery | 3.4.130 E. Pedestrian Access Entry to interior building from street required at break in facade in form of a Forecourt Frontage (see Section 3.4.080) or a Plaza (see Section 4.2.070). | [image omitted; see the official code] Ground floor units facing a street or alley must be accessed from that street or alley by an allowed frontage type(s). Stairwells and upper story corridors must be enclosed within the conditioned portion of the primary structure. Primary entry doors to individual residential units may not be sliding doors. Courtyard required when building's main body length is greater than 260'. Courtyard must be at least 50' by 100'. | [image omitted; see the official code] F. Open Space No open space requirement for ground floor or 2nd floor units. At least 25% of units above the 2nd floor shall have a usable balcony with minimum dimensions of 5'.
(Amended by Ordinance 24-01, adopted Jan. 23, 2024)
Ask a question about Hayward law
Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.
