§ 10-8.33 — DESIGN STANDARDS
Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 10-8.33
Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/ade90343-370c-4c2b-a083-be220711cc26
SEC. 10-8.33 - DESIGN STANDARDS.
Grading or clearing activity, whether or not of a nature that requires a permit under the provisions of this article, shall be designed in accordance with the following standards. (a) General Provisions. All grading or clearing shall be designed to: 1. Preserve or imitate the existing slope of the land, especially at all apparent horizons; 2. Retain trees and other native vegetation which stabilize steep hillsides, retain moisture, prevent erosion, and enhance the appearance of the City; 3. Replace removed plant life with plants that are drought resistant, easily established, fast growing, aesthetically pleasing, suited to slope and soil conditions, and that inhibit the spread of fire; 4. Locate building pads in such a manner as to permit ample room for adequate landscaping drainage and erosion control between and around buildings; 5. Minimize cuts and fills and avoid permanent scarring on hillsides; 6. Round off, in a natural manner, the top and toe of cut-and-fill slopes for both building pads and road grades; 7. Take into consideration geologic hazards and adverse soil conditions and their effect on the future stability of the development; 8. All grading/clearing for development located in the Hayward hills as defined in the "City of Hayward Hillside Design and Urban/Wildland Interface Guidelines," adopted February 16, 1993, by Resolution 93-037 shall be in conformance with the Hillside Design Guidelines encompassed within said guidelines. (b) Minimum Design Standards for Cuts. 1. Maximum Slope. Cut surfaces shall not be steeper than is safe for the intended use or steeper than the ratio of one and one-half horizontal to one vertical unless a soils engineer investigates the site and states that the proposed deviation will not endanger any private property, public way or place, or adversely affect any drainage facilities. Excavation may be required to be made with a cut face flatter in slope than the ratio of two horizontal to one vertical to maintain either the stability of the slope or the appearance of the site. 2. Drainage and Terracing. Drainage and terracing shall be provided as required in paragraph (e) of this section, "Minimum Design Standards for Drainage and Terracing," as shown on Standard Detail, SD-104; (c) Minimum Design Standards for Fills. 1. General. Unless otherwise recommended in the approved soils engineering report or, in the absence of an approved soils engineering report unless specifically waived by the City Engineer, fills shall conform to the standards set forth herein. 2. Compaction. All fills shall be placed under the general observation of a soils engineer. Unless otherwise stated in the soils report, all fills shall be placed in layers not to exceed six inches and compacted to a minimum of 90 percent of maximum density as determined by California Test Method 216 and 231 or ASTM 1557 Test Method. The frequency of testing shall be specified in the "California Department of Transportation Construction Manual." The City Engineer may at any time perform soils tests, at the permittee's expense, to evaluate the characteristics of the material in or being placed. 3. Preparation of Ground. The natural ground surface shall be prepared to receive fill by removing vegetation, topsoil, miscellaneous debris, or previously non-engineered fill. Fills shall be keyed and benched into sound bedrock or competent material as determined by the soils engineer. A drainage bench, exposed beyond the toe of the fill and sloped for sheet overflow, shall be constructed. A V-ditch designed to intercept this water runoff may be provided as an alternate. Compacted fills, terminating onto natural slopes steeper than the ratio of two horizontal to one vertical will be permitted only when the total slope can be demonstrated to be stable by a stability analysis performed by a soils engineer. 4. Fill Slope. No compacted fill shall be made which creates an exposed surface steeper in slope than the ratio of two horizontal to one vertical unless recommended by the soils engineer based on slope analysis that demonstrates the integrity of the slopes proposed. Fill slopes may be required that are flatter than the ratio of two horizontal to one vertical to maintain either the stability of the slope or the appearance of the site. 5. Fill Material. No detrimental amounts of organic material shall be permitted in structural fills. No rock or similar irreducible materials with a maximum dimension greater than 12 inches shall be buried or placed in fills except as recommended in a soils engineer's report that: (i) Designates the area on the grading plan where the irreducible material will be placed; (ii) Requires the placement of the irreducible material ten vertical feet or more below grade; (iii) Specifies that fine-grained earth material shall fill all spaces between the irreducible material; (iv) Provides for the continuous inspection of the placement of the irreducible material. 6. Drainage and Terracing. Drainage and terracing shall be provided as required in paragraph (e) of this section. (d) Minimum Design Standards for Setbacks. Cuts and fills shall be set back from property lines and buildings shall be set back from cut or fill slopes in accordance with City of Hayward Standard Detail SD-104. Minimum setbacks may be increased or retaining walls may be used to reduce the required setback when approved by conditions of a grading/clearing permit. Upon recommendation of the soils engineer of foundation design, encroachment into this area may be allowed by the City Engineer provided that said encroachment conforms to all applicable regulations of the City. (e) Minimum Design Standards for Drainage and Terracing. 1. General. Storm drainage structures, systems, and facilities shall be provided as required by the City Engineer and in accordance with Standard Specifications and Standard Details of the City of Hayward. Design shall be in accordance with recognized principles of hydraulics. 2. Disposal. All drainage facilities shall be designed to carry surface waters to the nearest practical street, storm drain, or waterway approved by the City Engineer as a safe place to discharge such waters. If the drainage device discharges onto natural ground, erosion shall be prevented by installation of riprap, energy dissipator, or other devices, as shown on Standard Details, SD-414, SD-415, SD-416, SD-417, and SD-418. 3. Site Drainage. Graded building sites or building pads for future construction shall have a minimum slope of 1 percent for unpaved areas and 0.5 percent for paved areas towards an approved drainage facility. A lesser slope may be approved by the City Engineer for sites graded in relatively flat terrain or where special drainage provisions are made. 4. Terrace. Terraces at least six feet in width shall be established at not more than 25-foot intervals vertical distance on all cut or fill slopes to control surface drainage and debris, except that where only one terrace is required it shall be located as approved by the City Engineer. Suitable access shall be provided to permit proper cleaning and maintenance. Swales or ditches on terraces shall have a uniform longitudinal grade of not less than 1 percent nor more than 3 percent and a minimum depth and width in conformance with the Standard Details. Such terraces shall drain into a paved gutter, pipe, or approved waterway adequate to convey the water to a safe disposal area. In environmentally or visually sensitive areas, alternative methods recommended by the Planning Director may be substituted for the above, if approved by the City Engineer. 5. Overflow Protection. Berms, swales, or other devices shall be provided at the top of cut or fill slopes to prevent surface waters from flowing over, onto, and damaging the face of the slope. (f) Design Standards for Erosion and Sediment Control. 1. General. All grading or clearing activities shall be conducted in a manner that will minimize the potential for erosion from the site. Both temporary and permanent erosion control measures may be necessary to comply with this requirement. Erosion control measures may include, but shall not be limited to, the following. (i) Temporary and permanent planting of exposed soils; (ii) Temporary dikes and swales; (iii) Sediment basins and traps; (iv) Retention basins; (v) Temporary and permanent storm drainage piping; (vi) Temporary straw bale dikes; and (vii) Temporary silt fences. 2. Design and Construction. The design and construction of erosion and sediment control facilities shall comply with the procedures and technical requirements of the "Manual of Standards." Retention and sediment basins designed for water depths of two feet or greater shall be enclosed with a six-foot chain-link fence, with an extension arm and three strands of barbed wire. 3. Reduction of Fire Hazard. Temporary and permanent planting of exposed soil shall be done in a manner that will minimize potential for grass or brush fires. 4. Maintenance. All sediment and erosion control measures shall be maintained so that they will fulfill their intended function throughout the October 1 to May 1 rainy season. 5. City Interventions. (i) In the event that necessary measures for the control of sediment or erosion are not taken at or prior to the occurrence of any rainstorm or other phenomenon that might cause any sedimentation or erosion, the City shall have the right to enter upon the site and construct such measures or do such other work as may be necessary to prevent further erosion or sedimentation, provided the City shall first give five days' written notice to the owner of the site, or the permittee, if a permit has been issued for the activity on the site, of its intent to do so. City shall be reimbursed for the cost of the work performed pursuant to this provision. In an emergency situation, no notice need be given. (ii) If, in the judgment of the City Engineer, measures for the control of sediment or erosion have been constructed according to approved design standards but such measures inadequately control sediment or erosion, the owner of the site or the permittee shall revise the erosion and sediment control measures to effect such control. In the event the owner or permittee fails to do so, the City may make the required revisions and may enter upon the site and make the necessary changes upon giving five days' written notice to the owner or permittee of its intent to do so. The City shall be reimbursed for the cost of the work performed pursuant to this provision. In an emergency situation, no notice need be given. (iii) In the event measures for the control of sediment or erosion have been constructed, but in the opinion of the City Engineer fail through overload or inadequate maintenance to perform the function for which they were intended, the owner of the site or the permittee shall reconstruct or maintain the sediment and erosion control measures as directed by the City Engineer. In the event the owner or permittee fails to do so, the City may enter upon the site and perform the reconstruction or maintenance that is necessary to restore proper performance of the erosion or sediment control measures upon giving five days' written notice to the owner or permittee of its intent to do so. The City shall be reimbursed for the cost of the work performed pursuant to this provision. In an emergency situation, no notice need be given.
Ask a question about Hayward law
Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.
