§ 8.20.150 — AUTOMATIC SPRINKLER SYSTEMS
Menifee Municipal Code (2026 S-15) · Menifee Municipal Code § 8.20.150
Corpus is an independent public-information project, not the official City of Menifee website. Stable reference: corpuslaw.us/code/90753f2a-c702-4010-8a0c-64244c5ec91b
§ 8.20.150 AUTOMATIC SPRINKLER SYSTEMS.
(A) Section 903.2 of the California Fire Code is deleted in its entirety and replaced with the following: 903.2 Where required. 1. In all new buildings and structures which are 3,600 square feet or greater, an approved automatic sprinkler system shall be provided regardless of occupancy classification. Where Sections 903.2.1 - 903.2.21 of the California Fire Code require more restrictive requirements than those listed below, the more restrictive requirement shall take precedence. 2. All existing buildings, except for one- and two-family dwellings, shall be retrofitted with automatic fire sprinklers when a structure exceeds 3,600 square feet and changes are made to the building including any of the following: change of use/occupancy, removal of an existing fire wall as defined by the California Building Code, or additions of 50% or more are made to the original building area and the resulting square footage exceeds 5,000 square feet. 3. One- and two-family dwellings shall have an automatic fire sprinkler system regardless of square footage in accordance with the California Residential Code. Fire sprinkler systems shall be installed in mobile homes, manufactured homes and multifamily manufactured homes with two dwelling units in accordance with Title 25 of the California Code of Regulations. Exceptions: Unless required elsewhere in this Code or the California Building Code, automatic fire sprinkler systems shall not be required for the following: 1. Spaces or areas in telecommunications buildings used exclusively for telecommunications equipment, associated electrical power distribution equipment, batteries not required to have an automatic sprinkler system by Section 1207 for energy storage systems and standby engines, provided that those spaces or areas are equipped throughout with an automatic smoke detection system in accordance with Section 907.2 and are separated from the remainder of the building by not less than 1-hour fire barriers constructed in accordance with Section 707 of the California Building Code or not less than 2-hour horizontal assemblies constructed in accordance with Section 711 of the California Building Code, or both. 2. Detached Group U occupancies used for agricultural purposes constructed in accordance with the California Building Code. 3. Detached non-combustible equestrian arena shade canopies that are open on all sides and used for riding only - no commercial, assembly or storage uses. 4. Non-combustible fueling station canopies not exceeding 10,000 square feet when separated from other buildings by a distance of not less than 50 feet. 5. Detached fabric or non-combustible shade structures that are open on all sides and used to shade playground equipment, temporary storage of vehicles and dining areas with no cooking. 6. Where determined by the Fire Chief that no major life safety hazard exists, and the fuel load does not pose a significant threat to firefighter safety or to other structures or property, automatic fire sprinklers may be exempted. The following exceptions in the California Fire Code shall not be allowed: a. Exception in Section 903.2.3 b. Exception in Section 903.2.11.3 (B) A new Section 903.3.5.3 is added to Section 903.3.5 of the California Fire Code to read as follows: 903.3.5.3 Hydraulically calculated systems. The design of hydraulically calculated fire sprinkler systems shall not exceed 90% of the water supply capacity. (Ord. 2022-364, passed 11-16-2022; Am. Ord. 2025-425, passed 11-19-2025)
Ask a question about Menifee law
Corpus searches the Menifee sections it holds and shows the ones that match, with their citations. Free, no sign-in.