§ 6-8.827 — Bacteriological sampling and testing
City of Ontario, California, Municipal Code (2026 S-32: Current through Ordinance 3338, passed 7-21-2026) · Ontario Municipal Code § 6-8.827
Corpus is an independent public-information project, not the official City of Ontario website. Stable reference: corpuslaw.us/code/93963490-5514-4b4b-8290-3c600a5fa1b7
Sec. 6-8.827. Bacteriological sampling and testing.
(a) Prior to bacteriological tests, an application for shutdown must be submitted pursuant to § 6-8.828. (b) Bacteriological tests shall be analyzed by a certified ELAP laboratory with approved fields of testing for said matrix. (c) Passing bacteriological tests on two (2) consecutive days shall be achieved prior to connecting the pipeline to the existing water system or placing the pipeline into service. Satisfactory bacteriological results shall conform to the following: (1) No total or fecal coliform. (2) A heterotrophic plate count less than 200 colony-forming units (CFU) per milliliter (ml). (3) Presence of chlorine residual at or below a concentration that does not interfere with the bacteriological testing and compromise the results. (d) If the initial chlorination fails to produce two (2) consecutive days of passing bacteriological tests, chlorination shall be repeated until two (2) consecutive days of passing bacteriological tests are achieved. (1) If the third attempt fails to obtain two (2) consecutive days of passing bacteriological test, then the City reserves the right, and at the sole expense of the contractor, to have the contractor clean the newly installed pipeline using a high-velocity flow that produces a neutral output discharge or other technology that removes excessive dirt or debris that has entered in the new installation that conforms to water conversation and NPDES requirements. (e) Laboratory reports shall be furnished upon issuance to the City and shall include, but not be limited to chain of custody, lab work sheet or summary letter imprinted with the laboratory’s name, address, and phone number. The report shall specify the field tests, laboratory analysis and results, and shall be signed by the laboratory director. The Engineer may require that laboratory reports be accompanied with any other form or document to ensure compliance with this section. (§ 4, Ord. 3297, eff. March 18, 2025)
Ask a question about Ontario law
Corpus searches the Ontario sections it holds and shows the ones that match, with their citations. Free, no sign-in.
