§ 8.04.204 — Amendments to Chapter 16 of the Palmdale Building Code

Municipal Code, City of Palmdale, California (Code 2026-05-05) · Palmdale Municipal Code § 8.04.204

Corpus is an independent public-information project, not the official City of Palmdale website. Stable reference: corpuslaw.us/code/aa4accdb-a4c8-400a-a9c2-b6a3df2c6380

§ 8.04.204: Amendments to Chapter 16 of the Palmdale Building Code.

Chapter 16, Design, of the Palmdale Building Code as adopted by incorporation of the California Building Code is hereby modified as follows: Section 1608.2 of the 2025 Edition of the California Building Code is amended to read as follows: Sec. 1608.2 Ground snow loads. The ground snow loads to be used in determining the design snow loads for roofs shall be 20 pounds per square foot. Sections 1613.5, 16135.1, 1613.5.2, and 1613.5.3 are added to read as follows: 1613.5 Amendments to ASCE 7. Section 1613.5 shall be added for amendments to the relevant provisions of ASCE 7. 1613.5.1 Values for Vertical Combinations. Modify ASCE 7 Section 12.2.3.1 Exception 3 as follows: 3. Detached one- and two-family dwellings up to two stories in height of light frame construction. 1613.5.2 Wood Diaphragms. Modify ASCE 7 Section 12.11.2.2.3 as follows: 12.11.2.2.3 Wood Diaphragms. The anchorage of concrete or masonry structural walls to wood diaphragms shall be in accordance with AWC SDPWS 41.5.1 and this section. Continuous ties shall be in addition to the diaphragm sheathing. Anchorage shall not be accomplished by use of toenails or nails subject to withdrawal nor shall wood ledgers or framing be used in cross-grain bending or cross-grain tension. The diaphragm sheathing shall not be considered effective as providing ties or struts required by this section. For structures assigned to Seismic Design Category D, E or F, wood diaphragms supporting concrete or masonry walls shall comply with the following: 1. The spacing of continuous ties shall not exceed 40 feet. Added chords of diaphragms may be used to form sub diaphragms to transmit the anchorage forces to the main continuous crossties. 2. The maximum diaphragm shear used to determine the depth of the sub diaphragm shall not exceed 75% of the maximum diaphragm shear. 3. Detached one- and two-family dwellings up to two stories in height of light frame construction. Section 1613.5.3 is added to Chapter 16 of the 2025 Edition of the California Building Code to read as follows: 1613.8.3 Structural Separation. Modify ASCE 7 Section 12.12.3 Equation 12.12-1 as follows: δM = Cdδmax Ie | (12.12-1)

( Ord. 1595 § 1 (Exh. A), 2022 ; Ord. 1661 , 10/21/2025 )

Ask a question about Palmdale law

Corpus searches the Palmdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.