For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.04.207 — Amendments to Chapter 19 of the Palmdale Building Code

Municipal Code, City of Palmdale, California (Code 2026-05-05) · Palmdale Municipal Code § 8.04.207

Corpus is an independent public-information project, not the official City of Palmdale website. Stable reference: corpuslaw.us/code/6d3237d1-141d-475b-ab1e-004f544393fb

§ 8.04.207: Amendments to Chapter 19 of the Palmdale Building Code.

Chapter 19, Concrete, of the Palmdale Building Code as adopted by incorporation of the California Building Code is hereby modified as follows: Section 1909.4 of the 2010 Edition of the California Building Code is amended to read as follows: 1909.4 Design. Structural plain concrete walls, footings and pedestals shall be designed for adequate strength in accordance with ACI 318, Section 22.4 through 22.8. Exception: For Group R-3 occupancies and buildings or other occupancies less than two stories above grade plane of light-frame construction, the required edge thickness of ACI 318 is permitted to be reduced to 6 inches (152 mm), provided that the footing does not extend more than 4 inches (102 mm) on either side of the supported wall. This exception shall not apply to structural elements designed to resist seismic lateral forces for structures assigned to Seismic Design Category D, E or F.

( Ord. 1410 § 2 (Exh. A), 2010 )

Ask a question about Palmdale law

Corpus searches the Palmdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.