§ 3.46.170: Service extensions.

A. Applicability. This rule is applicable to both: 1. Utility service facilities that extend from the utility's distribution line facilities to the service delivery point; and 2. Service-related equipment required of the applicant on the applicant's premises to receive electric service. B. General. 1. Design. The utility will be responsible for planning, designing and engineering service extensions using the utility's standards for design, materials and construction. Applicant may elect to design that portion of the new service extension normally designed by the utility in accordance with the applicant design provisions of section 3.46.160. 2. Service facilities. The utility's service facilities shall consist of: a. Primary or secondary underground or overhead service conductors; b. Poles to support overhead service conductors; c. Service transformers; d. Utility-owned metering equipment; and e. Other utility-owned service related equipment. 3. Ownership of facilities. Service facilities installed under the provisions of this rule shall be owned, operated, and maintained by the utility if they are: a. Located in the street, road or a public right-of-way area; b. Installed by the utility under subsection (D)(2) of this section on the applicant's premises for the purpose of the delivery of electric energy to applicant; or c. Installed by applicant under the provisions of this rule, and conveyed to the utility. 4. Private lines. The utility shall not be required to connect service facilities to or serve any applicant from electric facilities that are not owned, operated, and maintained by the utility. 5. Special or added facilities. Any special or added facilities the utility installs at the request of applicant will be installed at the applicant's expense in accordance with section 3.46.030. 6. Temporary service facilities. Service facilities installed for temporary service or for operations of speculative character or questionable permanency shall be made in accordance with the fundamental installation and ownership provisions of this rule, except that all charges and refunds shall be made under the provisions of section 3.46.140. 7. Street lights. Street light services and appurtenant facilities shall be installed in accordance with the service provisions of the applicable street light schedule. 8. Contracts. Each applicant requesting service may be required to execute a written contract prior to the utility performing its work to establish service. Such contract shall be in the form provided by the utility or otherwise acceptable and approved by the utility. This contract shall specify the size of the service connection desired, the property to be served and the purpose for which the electricity is to be used. The information supplied by the applicant shall be considered as authoritative and final. If any error in the application causes the installation of a service connection that is improper either in type, size or location, the cost of all changes required shall be paid by the applicant. 9. Distribution line extension. Whenever the utility's distribution system is not complete to the point designated by the utility where the service extension is to be connected to the utility's distribution system, the extension of distribution line facilities will be installed in accordance with section 3.46.160. 10. Rights-of-way. Rights-of-way or easements may be required by the service facilities on applicant's property to serve only the applicant. a. Service facilities. If the service facilities must cross property owned by a third party to serve the applicant, the utility may, at its option, install such service facilities after appropriate rights-of-way or easements, satisfactory to the utility, are obtained without cost to the utility. b. Distribution line extensions. If the utility's facilities installed on the applicant's property, or third-party property, will be or are designed to serve adjacent property, then the utility may, at its option, install its facilities under section 3.46.160, after appropriate rights-of-way or easements, satisfactory to the utility, are obtained without cost to the utility. c. Clearances. Any necessary rights-of-way or easements for the utility's facilities shall have provisions to maintain legal clearances from adjacent structures. d. Reasonable care to prevent damage. The customer shall exercise reasonable care to prevent the facilities of the utility upon the premises from being damaged or destroyed, and shall not relocate or otherwise interfere with them, and, if any defect is discovered, shall promptly notify the utility. 11. Access to applicant's premises. The utility shall, at all times, have the right to enter and leave the applicant's premises for any purpose connected with the furnishing of electric service (meter reading, inspection, testing, routine repairs, replacement, maintenance, emergency work, etc.) and the exercise of any and all rights secured to it by law, under the utility's tariff schedules. These rights include, but are not limited to: a. The use of a utility-approved locking device, if the applicant desires to prevent unauthorized access to the utility's facilities; b. Safe and ready access for utility personnel free from unrestrained animals; c. Unobstructed ready access for the utility's vehicles and equipment to install, remove, repair, or maintain its facilities; d. Removal of any and all of its property installed on the applicant's premises after the termination of service. 12. Service connections. Only personnel duly authorized by the utility are allowed to connect or disconnect service conductors to or from the utility's distribution lines, remove meters, unless otherwise allowed pursuant to utility tariff schedules, remove utility-owned service facilities, or perform any work upon utility-owned existing facilities. 13. Application made in advance; utility not liable for delays. Due to the long lead time for engineering, material acquisition, crew scheduling and construction, application for service must be made as far in advance as possible. After receipt of fees, service charges and deposits and clearance from the inspection agency having jurisdiction, the utility shall endeavor to complete within a reasonable time the installation of the necessary facilities. However, the utility shall not be liable for any delays encountered in completing the installation. 14. Customer shall pay utility overtime when necessary. If, for any reason of the applicant, installation of a service cannot be accomplished during standard working hours, the applicant shall pay in advance the estimated cost of the utility overtime, to the extent that it exceeds any costs included in other charges. 15. Obligation of utility. The utility shall be obligated to provide facilities adequate to serve only the load initially specified and connected, regardless of the rating of the service equipment, service switch or breaker. Increased loads will be considered as new installations, and the customer shall pay the net cost of any changes required in the utility facilities and may be required to make specified changes in the service facilities or equipment to accommodate the increase load or the type of service to be supplied by the utility. C. Metering facilities. 1. General. a. Meter all usage. Delivery of all electric power and energy will be metered, unless otherwise provided for by the utility's tariff schedules or by other applicable laws. b. Meter location. All meters and associated metering equipment shall be located at some protected location on applicant's premises as approved by the utility. 2. Number of meters. Normally only one meter will be installed for a single residential or nonresidential enterprise on a single premises, except: a. When otherwise required or allowed under the utility's tariff schedules; b. At the option of and as determined by the utility, for its operating convenience, consistent with its engineering design; c. When required by law or local ordinance; or d. When additional services are granted by the utility. A single meter is required for each single enterprise operating in one building or group of buildings or other development on a single premises such as, but not limited to, a commercial business, school campus, industrial manufacturer, or recreational vehicle park, unless otherwise approved by the utility. 3. Multiple occupancy. In a building with two or more tenants, or where more than one meter is furnished on the same premises, the meters normally shall be grouped at one central location, or as otherwise specified by the utility, and each meter position or socket shall be clearly and permanently marked by applicant, customer, or owner of the premises to indicate the particular unit, occupancy, or load supplied by it. a. Residential or nonresidential. For revenue billing, electric service shall be individually metered to each tenant in a residential or nonresidential building or group of buildings or other development on a single premises with multiple tenants or enterprises (such as, but not limited to, an office building or shopping center complex). Alternative metering arrangements as determined by the utility may be allowed only as specified in section 3.46.190 and applicable rate schedules. D. Service extensions. 1. General location. The location of the service extension shall extend: a. Public right-of-way area. From the point of connection at the distribution line to the applicant's nearest property line abutting upon any street, highway, road, or right-of-way, along which it already has, or will install, distribution facilities; and b. Private party. On private property, along the shortest, most practical and available route (clear of obstructions) as necessary to reach a service delivery point designated by the utility. 2. Number of service extensions. The utility will not normally provide more than one service exten-sion, including associated facilities, either overhead or underground, for any one building or group of buildings, for a single enterprise on a single premises, except: a. Tariff schedules. Where otherwise allowed or required under the utility's tariff schedules; b. Utility convenience. At the option of and as determined by the utility, for its operating convenience, consistent with its engineering design for different voltage and phase classification, or when replacing an existing service; c. Ordinance. Where required by city ordinance or other applicable law, for such things as fire pumps, fire alarm systems, etc.; or d. Other. The utility may charge for additional services provided under this subsection, as special or added facilities. 3. Underground installations. a. Underground service mandatory. Installation of electric service facilities for all new services shall be underground and installed according to applicable tariff schedules, laws, city ordinances, underground structure standards, and utility plans and specifications supplied for each specific installation. b. When requirement waived. The requirement of this section may be waived if technical or physical conditions make underground installation infeasible in the utility's judgment. 4. Overhead installations. a. Overhead service extensions will be allowed only when underground service is not feasible in the utility's judgment as specified in subsection (D)(3)(b) of this section. But, the customer may be required to provide utility-approved facilities to accommodate future conversion to underground service. b. The applicant shall provide a suitable location for the termination of the overhead service wires. The location of the termination is subject to approval of the utility and any inspection authority having jurisdiction and must meet all applicable codes. c. Overhead service wires shall, in all cases, be furnished and installed by the utility. The applicant shall install the service entrance conductors from the point of termination of the utility's service wires to the applicant's meter or switchgear lugs. 5. Unusual site conditions. In cases where the applicant's building is located a considerable distance from the available distribution line or where there is an obstruction or other deterrent obstacle or hazard such as plowed land, ditches, or inaccessible security areas between the utility's distribution line and the applicant's building or facility to be served that would prevent the utility from prudently installing, owning, and maintaining its service facilities, the utility may, at its discretion, waive the normal service delivery point location. In such cases, the service delivery point will be at such other location on applicant's property as may be mutually agreed upon; or, alternatively, the service delivery point may be located at or near the applicant's property line as close as practical to the available distribution line. E. Responsibilities for new service extensions. 1. Applicant responsibility. In accordance with the utility's design, specifications, and requirements for the installation of service extensions, subject to the utility's inspection and approval, the applicant is responsible for: a. Service extensions. (1) Clear route. Providing, or paying for, a route on any private property that is clear of obstructions which would inhibit the construction of either underground or overhead service extensions. (2) Excavation. All necessary trenching, backfilling, and other digging as required, including permit fees. (3) Conduits and substructures. (a) Furnishing, installing, owning, and maintaining all conduits, including pull ropes, and substructures on the applicant's premises. (b) Installing, or paying for, any conduits and substructures in the utility's franchise area (or rights-of-way, if applicable) as necessary to install the service extension. (c) Conveying ownership to the utility upon its acceptance of those conduits and substructures not on the applicant's premises. (4) Protective structures. Furnishing, installing, owning, and maintaining all necessary protective structures as specified by the utility for utility's facilities on the applicant's premises. b. Applicant's facility design and operation. The applicant shall be solely responsible to plan, design, install, own, maintain, and operate facilities and equipment beyond the service delivery point, except for utility-owned metering facilities, in order to properly receive and utilize the type of electric service available from the utility. Refer to section 3.46.030 for a description, among other things, of: (1) Available service delivery voltages and the technical requirements and conditions to qualify for them; (2) Customer utilization voltages; (3) Load balancing requirements; (4) Requirements for installing electrical protective devices; (5) Loads that may cause service interference to others; and (6) Motor starting limitations. c. Required service equipment. The applicant shall, at his or her sole liability, risk, and expense, be responsible to furnish, install, own, maintain, inspect, and keep in good and safe condition, all facilities of any kind or character on the applicant's premises that are not the responsibility of the utility but are required by the utility for the applicant to receive service. Such facilities shall include, but are not limited to, the overhead or underground termination equipment, conduits, service entrance conductors from the service delivery point to the location of the utility's metering facilities, connectors, meter sockets, meter and instrument transformer housing, service switches, circuit breakers, fuses, relays, wire ways, metered conductors, machinery and apparatus of any kind or character. Detailed information on the utility's service equipment requirements will be furnished by the utility. d. Coordination of electrical protective devices. When, as determined by the utility, the applicant's load is of sufficient size as to require coordination of response time characteristics between the applicant's electrical protective devices (circuit breakers, fuses, relays, etc.) and those of the utility, it shall be the applicant's responsibility to provide such coordination in accordance with section 3.46.020. e. Liability. The utility shall incur no liability whatsoever, for any damage, loss or injury occasioned by: (1) Applicant-owned equipment or the applicant's transmission and delivery of energy; or (2) The negligence, omission of proper protective devices, want of proper care, or wrongful act of the applicant, or any agents, employees, or licensees of the applicant, on the part of the applicant in installing, maintaining, using, operating, or interfering with any such conductors, lines, machinery, or apparatus. f. Facility tampering. The applicant shall provide a suitable means acceptable to the utility for placing its seals on meter rings and covers of service enclosures and instrument transformer enclosures which protect unmetered energized conductors installed by the applicant. All utility-owned meters and enclosure covers will be sealed only by the utility's authorized employees and such seals shall be broken only by the utility's authorized employees. However, in an emergency, the utility may allow a public authority or other appropriate party to break the seal. Any unauthorized tampering with utility-owned seals or connection of applicant-owned facilities to unmetered conductors at any time is prohibited and is subject to the provisions of section 3.46.120 for unauthorized use. g. Transformer installations on applicant's premises. Transformer installations on the applicant's premises shall be as specified by the utility and in accordance with the following applicable provisions: (1) Space for transformers. The applicant shall provide space on the applicant's premises at a location approved by the utility for a standard transformer installation, including any necessary switches, capacitors, and electric protective equipment where required, if: (a) In an overhead area, the utility determines that the load to be served is such that a separate transformer installation; or (b) If the utility determines that the installation of a pad-mounted or subsurface transformer of any size is required on the applicant's premises to serve only the applicant. (2) Pad-mounted equipment. In the utility's standard installation, the applicant shall furnish, install, own, and maintain, at his or her expense, substructures and any required protective structures as specified by the utility for the proper installation of the transformer, switches, capacitors, etc., as determined by the utility. (3) Transformer room or vault. Where applicant requests and the utility approves the installation of the transformer in a vault or room on the applicant's premises, rather than the utility's standard pad-mounted installation: (a) The room or vault on the applicant's premises shall be furnished, installed, owned, and maintained by the applicant and shall meet the utility's specifications for such things as access, ventilation, drainage, grounding system, etc. (b) If space cannot be provided on the applicant's premises for the installation of a transformer on either a pad or in a room or vault, a vault will be installed at the applicant's expense in the street near the property line. It shall be the applicant's responsibility to install, or pay for, such vault if not restricted by governmental authority having jurisdiction, and the applicant shall convey ownership of the vault to the utility upon its acceptance. The additional facilities shall be treated as special or added facilities under the provisions of section 3.46.030. (c) If the utility's installed cost for the transformer in the room or vault is more costly than the standard pad-mounted transformer installation, the additional costs shall be paid by the applicant as special or added facilities. (4) (Reserved) (5) Transformer lifting requirements. Where the utility has installed or agrees to install, transformers at locations where the utility cannot use its standard transformer lifting equipment and special lifting facilities are required to install or remove the transformers on the applicant's premises, the applicant shall, at his or her expense: (a) Furnish, install, own, and maintain permanent lifting facilities and be responsible for lifting the transformer to and from its permanent position; or (b) Provide, or pay for, portable lifting facilities acceptable to the utility for installing or removing the transformers. Rights-of-way and space provisions shall be provided by the applicant such that access and required clearances from adjacent structures can be maintained. The utility may require a separate contract for transformer lifting requirements. (6) Overhead transformers. In remote areas or in areas not zoned for residential or commercial use or for underground services, pad-mounted transformers are preferred for installation on the applicant's premises; however, where the utility determines that it is not practical to install a transformer on a pad, in a room or vault, the utility may furnish a pole-type structure for an installation not exceeding 500 kVA. h. Building code requirements. Any service equipment and other related equipment owned by the applicant, as well as any vault, room, enclosure, or lifting facilities for the installation of transformers shall conform to applicable laws, codes, and ordinances of all governmental authorities having jurisdiction. i. Reasonable care. The applicant shall exercise reasonable care to prevent the utility's service extension, other utility facilities, and meters owned by the utility or others on the applicant's premises from being damaged or destroyed, and shall refrain from interfering with the utility's operation of the facilities and shall notify the utility of any obvious defect. The applicant may be required to provide and install suitable mechanical protection (barrier posts, etc.) as required by the utility. 2. Utility responsibility. a. Service, meter and transformers. The utility will furnish, install, own, and maintain the following service facilities as applicable after the applicant meets all requirements to receive service: (1) Underground service. A set of service conductors to supply permanent service from the distribution line source to the service delivery point approved by the utility. (2) Riser materials. Any necessary pole riser material for connecting underground services to an overhead distribution line. (3) Overhead service. A set of overhead service conductors and support poles to supply permanent service from a distribution line source to a suitable support at the service delivery point approved by the utility. Such support shall be of a type and located such that service wires may be installed in accordance with good engineering practice and in compliance with all applicable laws, ordinances, rules, and regulations, including those governing clearances and points of attachment. (4) Metering. When the meter is owned by the utility, the utility will be responsible for the necessary instrument transformers, where required, test facilities, meters, associated metering equipment, and the metering enclosures when the utility elects to locate metering equipment at a point that is not accessible to the applicant. (5) Transformer. The transformer where required, including any necessary switches, capacitors, electrical protective equipment, etc. When either a pad-mounted or overhead transformer is installed on the applicant's premises, the service extension shall include the primary conductors from the connection point at the distribution supply line to the transformer and the secondary conductors, if any, from the transformer to the service delivery point. b. Special conduit installations. The utility shall own and maintain service conduits only if: (1) They are located in the same trench with distribution facilities; and (2) When it is necessary to locate conduits on property other than that owned by the applicant, as determined by the utility, or as may be required by local authorities. c. Cable-in-conduit. In those cases where the utility elects to install its service conductors using pre-assembled cable-in-conduit (CIC), the conduit portion will be considered a part of the conductor installation provided by the utility. d. Government inspection. The utility will establish electric service to the applicant following notice from the governmental authority having jurisdiction that the applicant-owned facilities have been installed and inspected in accordance with any applicable laws, codes, ordinances, rules, or regulations, and are safe to energize. 3. Installations options. a. Utility-performed work. Where requested by applicant and mutually agreed upon, the utility may perform that portion of the new service extension work normally the responsibility of applicant according to subsection (E)(1) of this section provided applicant pays the utility its estimated installed cost. b. Applicant-performed work. Under competitive bidding, the applicant may install that portion of the new service extension normally installed and owned by the utility in accordance with the same provisions outlined in section 3.46.160. F. Payments by applicant. 1. Applicant is responsible to pay the utility in advance of the utility commencing its work: a. Pole riser. The utility's estimated installed costs of any riser materials on its poles. b. Utility's total estimated cost. The utility's total estimated installed cost, including appurtenant facilities, such as connectors, service conductors, service transformers, metering equipment, and the conduit portion of CIC cable. c. Other. The utility's total estimated installed cost for any work it performs that is the applicant's responsibility or performs for the convenience of the applicant. G. Existing service facilities. 1. Service reinforcement. a. Utility-owned. When the utility determines that its existing service facilities require replacement, the existing service facilities shall be replaced as a new service extension under the provisions of this section. b. Applicant-owned. When the utility determines that existing applicant-owned service facilities, installed under a prior rule, require replacement, such replacement shall be accomplished under the provisions for a new service extension, except that if the utility determines that any portion of the applicant's existing service conductors can be utilized by the utility, the applicant will convey any such usable part to the utility and an appropriate credit by the utility may be allowed to the applicant. The applicant will replace or reinforce that portion of the service extension which applicant will continue to own under the provisions of this rule for new services. 2. Service relocation or rearrangement. a. Utility convenience. When, in the judgment of the utility, the relocation or rearrangement of a service, including utility-owned transformers, is necessary for the maintenance of adequate service or for the operating convenience of the utility, the utility normally will perform such work at its own expense, except as provided in subsection (G)(2)(b) and (F)(5) of this section. b. Applicant convenience. Any relocation or rearrangement of the utility's existing service facilities at the request of the applicant (aesthetics, building additions, remodeling, etc.) and agreed upon by the utility shall be performed in accordance with subsection E of this section, except that the applicant shall pay the utility its total estimated costs. In all instances, the utility shall abandon or remove its existing facilities, at the option of the utility, rendered idle by the relocation or rearrangement. 3. Impaired access and clearances. Whenever the utility determines that: a. Access. Its existing service facilities have become inaccessible for inspecting, operating, maintenance, meter reading, or testing; or b. Clearances. A hazardous condition exists or any of the required clearances between the existing service facilities and any object becomes impaired under any applicable laws, ordinances, rules, or regulations of the utility or other public authorities, then the following applies; c. Corrective action. The applicant or owner shall, at the applicant's or owner's expense, either correct the access or clearance infractions or pay the utility its total estimated cost to relocate its facilities to a new location which is acceptable to the utility. The applicant or owner shall also be responsible for the expense to relocate any equipment which applicant owns and maintains. Failure to comply with corrective measures within a reasonable time may result in discontinuance of service. 4. Overhead to underground service conversions. a. When new services installed. Where an existing overhead distribution line is replaced by an underground distribution system, new underground services will be installed under this section. b. Applicant convenience. Where overhead services are replaced by underground services for the applicant's convenience, the applicant shall perform all excavation, furnish and install all substructures, and pay the utility its total estimated installed cost to complete the new service and remove the overhead facilities. 5. Damaged facilities. When the utility's facilities are damaged by others, the repair will be made by the utility at the expense of the party responsible for the damage. Applicants are responsible for repairing their own facilities. 6. Subdivision of premises. When the utility's service facilities are located on private property and such private property is subsequently subdivided into separate premises with ownership divested to other than the applicant or customer, the subdivider is required to provide the utility with adequate rights-of-way satisfactory to the utility for its existing facilities and to notify property owners of the subdivided premises of the existence of the rights-of-way. When adequate rights-of-way are not granted as a result of the property subdivision, the utility shall have the right, upon written notice to the applicant, to discontinue service without obligation or liability. The existing owner, applicant, or customer shall pay to the utility the total estimated cost of any required relocation or removal of the utility's facilities. A new electric service will be re-established in accordance with the provisions of subsection E of this section for new service and the provisions of any other applicable utility rules. H. Exceptional cases. When the application of this rule appears impractical or unjust to either party, or ratepayers, the utility or applicant may refer the matter to the utilities administrative resources manager for a special ruling or for approval of special conditions which may be mutually agreed upon. I. Service design and engineering. Service designs, plans and estimates to determine service charges or deposits, will not be initiated by the utility until it has reasonable assurance that the applicant's project will be built. This assurance is normally taken as the issuance of a building permit. Should the applicant desire these service plans and the amount of charges at an earlier time, the applicant may pay a deposit for early design as determined by the utility. The design work will then be scheduled along with all other eligible applicants. A deposit for early design will be credited to the cost of the design and installation of the service or refunded as appropriate. The cost of multiple designs to explore options or redesigns required by changes beyond the control of the utility shall be paid by the applicant. J. Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: "Applicant" means a person or agency requesting the utility to supply electric service. "Conduit" means ducts, pipes, or tubes of certain metals, plastics or other materials acceptable to the utility, including pull wires and concrete encasement where required, for the installation and protection of electric wires and cables. "Distribution lines" means the utility's overhead and underground facilities which are operated at distribution voltages as set forth in the utility's section 3.46.030 and which are designed to supply two or more services. "Excavation" means all necessary trenching, backfilling, and other digging as required to install service extensions, including furnishing of any imported backfill material, concrete encasement to protect conduit, and disposal of spoil as required, surface repair and replacement, landscape repair and replacement. "Insignificant loads" means small operating loads such as gate openers, valve controls, clocks, timing devices, fire protection equipment, alarm devices, etc. "Intermittent loads" means loads which, in the opinion of the utility, are subject to discontinuance for a time or at intervals. "Premises" means all of the real property and apparatus employed in a single enterprise on an integral parcel of land undivided, excepting in the case of industrial, agricultural, oil field, resort enterprises and public or quasi-public institutions, by a dedicated street, highway or public thoroughfare or a railway. Automobile parking lots constituting a part of and adjacent to a single enterprise may be separated by an alley from the remainder of the premises served. "Protective structures" means fences, retaining walls (in lieu of grading), sound barriers, posts, barricades and other structures as required by the utility. "Seasonal service" means electric service to establishments which are occupied seasonally or intermit-tently, such as seasonal resorts, cottages, or other part-time establishments. "Service delivery point" means where the utility's service facilities are connected to either the applicant's conductors or other service termination facility designated and approved by the utility. "Service extension" means the overhead and underground primary or secondary facilities, including, but not limited to, utility-owned service facilities and applicant-owned service facilities, extending from the point of connection at the distribution line to the service delivery point. When an underground service extension is supplied from a utility-designated overhead pole, the beginning point of connection to the utility's distribution line shall be where the service extension is connected to the utility's overhead distribution line conductors. "Substructures" mean the surface and subsurface structures which are necessary to contain or support the utility's electric facilities. The term "substructures" includes, but is not limited to, splice boxes, pull boxes, equipment vaults and enclosures, foundations or pads for surface-mounted equipment.

( Code 1980, § 3.46.170 ; Ord. No. 736 § 2, 2004 ; Ord. No. 870 (Recodification), 2014 )

Ask a question about Rancho Cucamonga law

Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.