§ 17.64.160 — Water Storage Tanks

Municipal Code of the City of San Marcos, California (Codified through Ordinance No. 2026-1582, enacted September 22, 2026. (Supp. No. 14)) · San Marcos Municipal Code § 17.64.160

Corpus is an independent public-information project, not the official City of San Marcos website. Stable reference: corpuslaw.us/code/442f3932-a04a-4daf-8471-38a6e47a1729

17.64.160 - Water Storage Tanks.

Section 507.2 of the California Fire Code is amended by the addition of Table 507.2 the requirements of which may, at the discretion of the Fire Chief, apply when required fire flow for single-family dwellings must be supplied by private water tanks due to the unavailability of water mains. Sec. 507.2.2 Water tanks. Water tanks for private residential fire protection, when authorized by the fire code official, shall comply with Table 507.2.2 and installed in accordance with NFPA 22. Water tanks for commercial fire protection, when authorized by the fire code official, shall be sized utilizing nationally-recognized standards. TABLE 507.2.2 RESIDENTIAL WATER TANK REQUIREMENTS Building Square Feet | Gallons Per Minute Water Flow | Capacity Gallons | Duration Minutes Up to 1,500 Over 1,500 | 250 250 | 5,000 10,000 | 20 40 When the exposure distance is one hundred feet (100') or less from an adjacent property, or where additional hazards or higher fire flow exists, the required water storage may be modified by the fire code official. 1. Tank bottom elevation shall be equal to or higher than the Fire Department connection on the premises. Regardless of domestic use, all tanks shall be equipped with a device that will ensure that the tank contains the designated amount of water for fire flow duration as determined by the FAHJ. Tank size may be increased to serve multiple structures on a single parcel. 2. Supply outlet shall be at least four inches in diameter from the base of the tank to the point of outlet at the Fire Department connection. The fire department connection shall have an approved means of controlling water flow. The fire department connection shall be at least one four-inch National Standard Thread (male), reduced to one two and one-half inch National Standard Thread (male). Additional outlets may be required. 3. Location of Fire Department outlet shall be shown on the plot plan when submitted to the FAHJ. Consideration will be given to topography, elevations, and distance from structures, driveway access, prevailing winds, etc. 4. The outlet shall be located along a fire apparatus access roadway and shall not be closer than 50 feet or further than 150 feet from the structure. 5. All exposed tank supply pipes shall be of an alloy or other material listed for above ground use. Adequate support shall be provided. 6. Water storage tanks shall be constructed from materials allowed by NFPA 22 and installed per manufacturer recommendations. 7. The fire code official may require any necessary information to be submitted on a plot plan for approval. 8. Vessels previously used for products other than water shall not be allowed. 9. The bottom of the water storage tank shall be level with or above the building pad.

(Ord. No. 2011-1341, 1-25-11; Ord. No. 2016-1429, 10-11-2016; Ord. No. 2019-1479, § 1(Exh. A), 10-22-2019; Ord. No. 2022-1525, § 1(Exh. A), 10-25-2022)

Ask a question about San Marcos law

Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.