For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.64.285 — Green Waste Recycling, Mulching, Composting Operations and Storage

Municipal Code of the City of San Marcos, California (Codified through Ordinance No. 2026-1582, enacted September 22, 2026. (Supp. No. 14)) · San Marcos Municipal Code § 17.64.285

Corpus is an independent public-information project, not the official City of San Marcos website. Stable reference: corpuslaw.us/code/d9673a66-42ab-4b36-9ae0-1e6898e98a55

17.64.285 - Green Waste Recycling, Mulching, Composting Operations and Storage.

Recycling facilities shall comply with the following provisions: (a) All green waste that cannot be processed on-site, such as stumps and fibrous plants, shall be immediately removed from the feedstock, stored in roll-off containers or bins and removed from the facility on a weekly basis. All plastic bags shall be removed prior to shredding material. (b) Permit Required - A permit shall be obtained from the San Marcos Fire Department prior to engaging in the operation and storing of processed wood chips, hogged material, fines, compost and raw product in association with yard waste and recycling facilities where the likelihood exists that spontaneous combustion could occur and present a threat from fire or hazardous substances to the welfare and public safety as determined by the Fire Department. The permit shall continue until revoked or for such period of time as may be designated by the Fire Department. Permits shall not be transferable and any change in use, occupancy, operation or ownership shall require a new permit. (c) Operational Plans - The following operational and activity plans will be required prior to operation: 1. Fire Suppression and Prevention Plan. A Fire Suppression and Prevention Plan shall be required and shall include, but not be limited to, the following: Access for firefighting, equipment and personnel water system (including adequate storage for fire flow), material handling equipment, diversion plan, dispersal areas, emergency response plan, and security. The storage shall be in a manner designed to prevent fires, and other requirements as deemed necessary by the Fire Department. 2. Emergency Fire Plan. All fires shall be reported to the Fire Department. The owner or operator shall develop a plan for monitoring, controlling and extinguishing spot fires and submit a plan for Fire Department review prior to approval. 3. Fire Dispersal Area Plan. The plan shall include a method for dispersal for larger fires. The operator shall develop a fire dispersal area for spreading burning product waste. This area is to be used to break up and scatter piles of burning product in all directions for fire extinguishment. 4. Emergency Operator Callback Response Plan. The operator shall provide an emergency response plan meeting the following criteria: The response time shall be within one hour of a fire or Fire Department request for the following equipment staffed with skilled operators, bulldozer, loaders and heavy duty equipment necessary to mitigate a fire. Notification shall be for 24 hours a day, seven days a week. Notification may occur by pager activation, telephonic contact or other approved means. 5. Incoming Waste Diversion Plan. To prevent stockpiling of material onsite, the operator shall develop a diversion plan for incoming green waste in the event of equipment failure or other impediments to the timely processing and shipping of green waste. (d) Fire Access Roadway - A fire access roadway shall be provided with a minimum width based upon material handling equipment requirements, with a surface covering as approved by the Fire Department. In no case shall the fire access roadway be less than 20 feet wide. (e) Storage Site - Storage sites shall be reasonably level and on all-weather surfaces. (f) Pile Separation - Piles shall be separated from adjacent piles by Fire Department access roadways. (g) Size of Piles - Pile height, width, and length shall be limited to, and determined by, site material handling equipment requirements and in no case shall the piles exceed 12 feet in height, 100 feet in width and 200 feet in length. (h) Static Pile Protection - The internal temperature of static piles and windrows shall be taken on a regular basis to monitor conditions within the windrows. Internal pile temperatures shall be taken at a point two-thirds the pile height, 12 to 24 inches from the surface, with a probe-type thermometer, and recorded weekly. Infrared thermometers may be used to monitor for hot spots at the surface once excessive temperatures are discovered. Temperatures above 158 degrees Fahrenheit are known to adversely affect microbial decomposition and are considered excessive. Once windrows exceed 170 degrees Fahrenheit, the windrows shall be reduced in size and monitored daily until temperatures drop below 158 degrees Fahrenheit. Windows shall be visually inspected on a regular basis. Once fires have started in any windrow(s) at a site, this visual inspection shall be a minimum daily requirement and shall continue until the threat of fire is no longer present. All records shall be kept on file at the facility and be made available for inspection. An operational plan indicating procedures and schedules for inspections, monitoring and restricting of excessive internal temperatures in the static piles shall be submitted to the FAHJ for review and approval. All green waste stockpiles shall be remixed, as necessary, to alleviate any fire due to spontaneous combustion or temperatures above 170 degrees Fahrenheit. (i) Firefighting Water Supply and Storage. Public Water Supply: The operators shall provide one or more fire hydrants (400-foot on center) and waterline mains. The waterline may be an approved above ground line with adequate protection against impact, fire flow reaction, supplied from a reliable water supply. Fire flow at the hydrant(s) shall be at least 1,000 gallons per minute at 20 psi for a flow duration of 2 hours. Private Water Supply: Above ground water storage tanks may, at the discretion of the Fire Marshal, be installed where public supply is not available or adequate or to support a deficient public supply, in order to meet fire flow requirements. Such supply shall consist of a minimum of two 10,000-gallon tanks. (j) Material Handling Equipment - Approved material-handling equipment shall be available for moving wood chips, hogged material, compost and raw product produced from yard waste and wood fines during firefighting operations. Vehicles used on all piles should be of a type that minimizes compaction. All vehicles operating on or around the piles shall have a Class A extinguisher of a 2-A rating, in addition to the normal Class B units required for the vehicles themselves. (k) Site Security - Pile storage areas shall be surrounded with approved fencing. Flinches shall be a minimum of 6 feet in height. (l) Smoking and Open Burning Prohibited - The operator shall prohibit smoking and open flame on the operational site, including smoking within vehicles. Approved signs shall be clearly and prominently posted, and the requirements of same shall be enforced by the operators. No open burning shall be permitted on-site. (m) Combustible Vegetation Control - The operator shall clear within 50 feet of either the raw green waste pile or mulch pile any combustible material, weeds, brush, trees or other vegetation (including mulch) that is, or could become, dry and capable of transmitting fire. Clearance shall be to bare earth or approved all-weather surfacing. Individual live trees within that distance may remain with approval of the FAHJ. (n) Site Equipment Maintenance—General Safety Rules - Welding operations shall be conducted a minimum of 30 feet from combustible materials, and a fire watch shall be established by operators to operate fire-extinguishing equipment. Refueling and on-site maintenance shall meet the requirements of California Fire Code Section 57 (Flammable and Combustible Liquids). (o) Security Bond/Financial Commitment for Cost Recovery - A security bond or alternate financial security acceptable to the City Attorney shall be submitted to the FAHJ, the amount of which shall depend on the size of operation and the likely expenses of any emergency response and/or enforcement action by the FAHJ to protect the public from fire or hazardous substances. The security bond/financial commitment shall be returned to the operator upon satisfactory closure of the operation, as approved by the FAHJ.

(Ord. No. 2014-1385, 1-28-2014; Ord. No. 2019-1479, § 1(Exh. A), 10-22-2019; Ord. No. 2022-1525, § 1(Exh. A), 10-25-2022)

Ask a question about San Marcos law

Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.