For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.64.210 — Mid-Rise Buildings

Municipal Code of the City of San Marcos, California (Codified through Ordinance No. 2026-1582, enacted September 22, 2026. (Supp. No. 14)) · San Marcos Municipal Code § 17.64.210

Corpus is an independent public-information project, not the official City of San Marcos website. Stable reference: corpuslaw.us/code/024c3905-a8f2-4b0a-86fc-8672f96270a9

17.64.210 - Mid-Rise Buildings.

In addition to other applicable provisions of this Code, other laws and regulations, and any policies of the chief, the provisions of this article apply to every newly constructed mid-rise building, of any type construction, or any mid-rise building which undergoes a complete renovation that requires the complete vacancy of the building to complete the renovation. Exceptions: The following structures, while defined as mid-rise buildings, will not be subject to the provisions of this article: 1. Buildings used exclusively as open parking garage. 2. Buildings where all floors above the fourth floor (16,764 mm) level are used exclusively as open parking garage. 3. Buildings such as power plants, lookout towers, steeples, grain houses, and similar structures with non-continuous human occupancy, when so determined by the chief. Building Access. Building access must be provided and approved by the chief. Automatic Fire Sprinklers/Standpipes. Every mid-rise building must be protected throughout by an automatic fire sprinkler system that is designed and installed in conformance with latest adopted Edition of NFPA 13 and in accordance with the following: 1. A control valve and a water flow alarm must be provided for each floor. Each control valve and flow alarm must be electronically supervised. 2. Every mid-rise building must be provided with a class I standpipe system that is interconnected with the fire sprinkler system. The system must consist of two and one-half-inch hose valves that must be located in each stair enclosure, on every floor level. Two hose outlets must also be located on the roof, outside of each stair shaft enclosure that penetrates the roof. The standpipe system must be designed, installed, and tested in accordance with the NFPA 14 edition as referenced in chapter 80 of the California Fire Code. 3. Fire Department standpipe connections and valves serving the floor must be within the vestibule and located in a manner so as not to obstruct egress when hose lines are connected and charged. Smoke Detection. Smoke detectors must be provided in accordance with this section. Smoke detectors must be connected to an automatic fire alarm system installed in accordance with the NFPA 72 edition as referenced in Chapter 80 of the California Fire Code. The actuation of any device required by this section shall operate the emergency voice alarm signaling system and shall operate all equipment necessary to prevent the circulation of smoke through air return and exhaust ductwork. Smoke detectors shall be located as follows: 1. In every mechanical equipment, electrical, transformer, telephone equipment, unmanned computer equipment, elevator machinery or similar room and in all elevator lobbies. Elevator lobby detectors shall be connected to an alarm verification zone or be listed as a releasing device. 2. In the main return-air and exhaust-air plenum of each air-conditioning system. The smoke detector shall be located in a serviceable area downstream of the last duct inlet. 3. At each connection to a vertical duct or riser serving two or more stories from a return-air duct or plenum of an air conditioning system. In R-1 R-2 Occupancies, an approved smoke detector is allowed to be used in each return-air riser carrying not more than 5,000 cubic feet per minute and serving not more than 10 air inlet openings. 4. For Group R-1 and R-2 Occupancies, in all corridors serving as a means of egress for an occupant load for 10 or more persons. Fire Alarm System. An approved and listed, automatic and manual, fully addressable and electronically supervised fire alarm system shall be provided in conformance with this code and California Building Code and NFPA 72 edition as reference in Chapter 80 of the California Fire Code. Emergency Voice Alarm Signaling System. The operation of any automatic fire detector or water flow device must automatically sound an alert tone followed by a pre-recorded voice instruction giving appropriate information and direction on a general or selective basis to the following terminal areas: 1. Elevators. 2. Elevator lobbies. 3. Corridors. 4. Exit Stairways. 5. Rooms and tenant spaces. 6. Dwelling units. 7. Hotel Guest Rooms. 8. Areas designated as safe refuge within the building. Fire Command Center. A fire command center for Fire Department operations shall be provided. The location and accessibility of the fire command center shall be approved by the Fire Code Official. The room shall be separated from the remainder of the building by not less than one-hour, fire barrier and be located on an exterior wall, not within building. The room shall be a minimum of 200 square feet with a minimum dimension of 10 feet. It shall contain the following facilities as a minimum: 1. Voice alarm and public address panels. 2. Fire Department communications panel. 3. Fire alarm annunciator panel. 4. Elevator annunciator panel (when Building exceeds 55 feet in height). 5. Status indicators and controls of air handling systems (Stairwell Pressurization). 6. Controls for unlocking stairwell doors. 7. Fire Pump status indicators (if required). 8. Complete building plans set. 9. Work Table. 10. Elevator control switches for switching of emergency power. Annunciation Identification. Control panels in the central control station shall be permanently identified as to their function. Water flow, automatic fire detection and manually activated fire alarms, supervisory and trouble signals shall be monitored by an approved, UL listed Central Monitoring Station and annunciated in the Fire Command Center by means of an audible and visual indicator. For the purposes of annunciation, zoning shall be in accordance with the following: 1. When the system serves more than one building, each building shall be considered as separate. 2. Each floor in a building shall be a separate zone. 3. When one or more risers serve the same floor, each riser shall be a separate zone. Elevators. Elevators and elevator lobbies shall comply with the provisions of Chapter 30 of the California Building Code. At least one elevator cab shall be assigned for fire department use and shall serve all floors of the building. This cab shall be provided large enough to accommodate an ambulance type stretcher in accordance with section 3002.4 of the California Building Code. Fire Department Communication System. An approved two-way, Fire Department communication system designed and installed in accordance with the NFPA 72 edition as referenced in Chapter 80 of the California Fire Code shall be provided for Fire Department use per section 907.2.13.2. Means of Egress. In addition to the requirements of Chapter 10, egress components of Mid-Rise buildings shall comply with the following: Extent of Enclosure. Stairway enclosures must be continuous and must fully enclose all portions of the stairway. Exit enclosure shall exit directly to the exterior of the building or include an exit passageway on the ground floor, leading to the exterior of the building. Each exit enclosure shall extend through the roof and be provided with a door that leads onto the roof. Pressurized Enclosures and Stairways. All required stairways and enclosures in a mid-rise building shall be pressurized as specified in the California Building Code Section 909. Pressurized Stairways shall be designed to exhaust smoke manually when needed. Vestibules. Pressurized stairway enclosures, serving mid-rise buildings shall be provided with a pressurized entrance vestibule on each floor that complies with the California Building Code Section 909. Pressure Differences. The minimum pressure difference within a vestibule shall be in accordance with the California Building Code Section 909. Locking of Stairway Doors. All stairway doors that are locked to prohibit access from the interior of the stairway shall have the capability of being unlocked simultaneously, without unlatching, upon a signal from the fire control room. Upon failure of normal electrical service, or activation of any fire alarm, the locking mechanism must automatically retract to the unlocked position. A telephone or other two-way communication system connected to an approved emergency service which operates continuously shall be provided at not less than every third floor in each required exit stairway vestibule. Approved signage shall be provided in each stairwell vestibule stating doors are locked, on which floor(s) entry may be made, and on which floor(s) a telephone is located. Hardware for locking of stairway vestibule doors shall be State Fire Marshal listed and approved by the Fire Code Official by permit before installation. Stairway doors located between the vestibules and stairway shaft shall not be locked. Emergency Response Maps - Geo- Referenced Preplans. Any new development, which necessitates updating of emergency response maps by virtue of new structures, hydrants, roadways or similar features, shall be required to provide map updates. The following should be provided: 1) A fire preplan in (ESRI) GIS format using the pre-configured GIS Starter Package provided by the City. A completed fire preplan shall include the GIS data and output PDF for use by the Fire Department. 2) Data deliverables (CAD and GIS) shall specifically include a site plan, building plan, all Utility shut-offs, fire sprinkler risers and shut-off valves, the fire department connection for sprinkler and class-I standpipe, all standpipe hose outlets, all stairwells, retail spaces, living units - numbers/locations, fire alarm panels, elevators, fire hydrants and all Knox boxes and key switch locations. Emergency Responder Communication Coverage shall be in accordance with Section 510 of the California Fire Code, the approved Fire Department Standards, and third party consultants.

(Ord. No. 2016-1429, 10-11-2016; Ord. No. 2019-1479, § 1(Exh. A), 10-22-2019; Ord. No. 2022-1525, § 1(Exh. A), 10-25-2022; Ord. No. 2025-1569, § 1(Exh. A), 12-9-2025)

Ask a question about San Marcos law

Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.