§ 18.08.030: Section 2304.10.9 is Added.
Section 2304.10.9 is added to read as follows: 2304.10.9 Nails, staples, or spikes in withdrawal. Nails, staples, or spikes shall not be used in withdrawal to resist the loads prescribed by this code. Exceptions: 1. Fasteners connecting finish materials weighing 10 psf or less. 2. Fasteners connecting sheathing may be used to resist wind uplift loads. 3. Fasteners connecting roofing or cladding, when specifically approved by this code or by an approved listing or testing authority. 4. Fasteners connecting mechanical or electrical components weighing 20 lb or less, or in the case of a distributed system, 5 lb/ft or less.
( Ord. 25-5 , 11/25/2025 )