§ 18.08.070 — Tables 2306.2(3), 2306.2(4), and 2306.2(5) are Added
Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 18.08.070
Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/f79b1d27-8997-4628-a4a0-757a7dc9f08e
§ 18.08.070: Tables 2306.2(3), 2306.2(4), and 2306.2(5) are Added.
Tables 2306.2(3), 2306.2(4), and 2306.2(5) are added as follows: Table 2306.2(3)UNBLOCKED Wood Structural Panel DIAPHRAGMS with Framing of Douglas-Fir Larch or Southern PineAllowable (ASD) Unit Shear Capacities (pounds per foot) Sheathing Grade | Common Nail Size | Minimum Fastener Penetration in Framing (in.) | Minimum Nominal Panel Thickness (in.) | Minimum Nominal Width of Nailed Face at Adjoining Panel Edges and Boundaries (in.) | SEISMIC | WIND 6 in. Nail Spacing at diaphragm boundaries and supported panel edges | 6 in. Nail Spacing at diaphragm boundaries and supported panel edges Case 1 | Cases 2,3,4,5,6 | Case 1 | Cases 2,3,4,5,6 Structural I | 8d | 1-3/8 | 3/8 | 23 | 240265 | 180200 | 335370 | 252280 10d | 1-1/2 | 15/32 | 23 | 285320 | 215240 | 400447 | 300335 Sheathing and Single-Floor (DOC PS1 and PS2) | 6d | 1-1/4 | 3/8 | 23 | 165185 | 125140 | 230260 | 175195 8d | 1-3/8 | 3/8 | 23 | 215240 | 160180 | 300335 | 225252 7/16 | 23 | 230255 | 170190 | 322357 | 237265 15/32 | 23 | 240265 | 180200 | 335370 | 252280 10d | 1-1/2 | 15/32 | 23 | 255290 | 190215 | 357405 | 265300 19/32 | 23 | 285320 | 215240 | 400447 | 300335 Notes: a. See AWC SDPWS for the following: For general construction requirements see 4.2.7. For specific requirements see 4.2.8.1 for wood structural panel diaphragms. See Appendix A for common nail dimensions. b. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. c. See AWC SDPWS Table 4.2C for Case definitions. d. See AWC SDPWS Table 4.2C for the apparent shear stiffness values (Ga). e. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. Table 2306.2(4)BLOCKED Wood Structural Panel DIAPHRAGMS with Framing of Douglas-Fir Larch or Southern PineAllowable (ASD) Unit Shear Capacities (pounds per foot) Sheathing Grade | Common Nail Size | Minimum Nail Bearing Length in Framing Member or Blocking (in.) | Minimum Nominal Panel Thickness (in.) | Minimum Nominal Width of Nailed Face at Adjoining Panel Edges and Boundaries (in.) | SEISMIC | WIND Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 & 4), and at all panel edges (Cases 5 & 6) | Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 & 4), and at all panel edges (Cases 5 & 6) 6 | 4 | 2-1/2 | 2 | 6 | 4 | 2-1/2 | 2 Nail Spacing (in.) at other panel edges (Cases 1, 2, 3, & 4) | Nail Spacing (in.) at other panel edges (Cases 1, 2, 3, & 4) 6 | 6 | 4 | 3 | 6 | 6 | 4 | 3 Structural I | 8d | 1-3/8 | 3/8 | 23 | 270300 | 360400 | 530600 | 600675 | 377420 | 505560 | 742840 | 840945 10d | 1-1/2 | 15/32 | 23 | 320360 | 425480 | 640720 | 730820 | 447505 | 595672 | 8951007 | 10221147 Sheathing and Single-Floor (DOC PS1 and PS2) | 6d | 1-1/4 | 3/8 | 23 | 185210 | 250280 | 375420 | 420475 | 260295 | 350392 | 525587 | 587665 8d | 1-3/8 | 3/8 | 23 | 240270 | 320360 | 480540 | 545610 | 335377 | 447505 | 672755 | 762855 7/16 | 23 | 255285 | 340380 | 505570 | 575645 | 357400 | 475532 | 707797 | 805902 15/32 | 23 | 270300 | 360400 | 530600 | 600675 | 377420 | 505560 | 742840 | 840945 10d | 1-1/2 | 15/32 | 23 | 290325 | 385430 | 575650 | 655735 | 405455 | 540602 | 805910 | 9171030 19/32 | 23 | 320360 | 425480 | 640720 | 730820 | 447505 | 595672 | 8951007 | 10221147 Notes: a. See AWC SDPWS for the following: For general construction requirements see 4.2.7. For specific requirements see 4.2.8.1 for wood structural panel diaphragms. See Appendix A for common nail dimensions. b. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. c. See AWC SDPWS Table 4.2A for Case definitions. d. See AWC SDPWS Table 4.2A for the apparent shear stiffness values (Ga). e. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. Table 2306.2(5)Blocked Wood Structural Panel DIAPHRAGMS with Framing of Douglas-Fir Larch or Southern PineUTILIZING MULTIPLE ROWS OF FASTENERS (HIGH-LOAD DIAPHRAGMS)Allowable (ASD) Unit Shear Capacities (pounds per foot) Sheathing Grade | Common Nail Size | Minimum Nail Bearing Length in Framing Member or Blocking (in.) | Minimum Nominal Panel Thickness (in.) | Minimum Nominal Width of Nailed Face at Adjoining Panel Edges and Boundaries (in.) | Lines of Nails | SEISMIC | WIND Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 & 4), and at all panel edges (Cases 5 & 6) | Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 & 4), and at all panel edges (Cases 5 & 6) 4 | 2-1/2 | 4 | 2-1/2 Nail Spacing (in.) at other panel edges (Cases 1, 2, 3, & 4) | Nail Spacing (in.) at other panel edges (Cases 1, 2, 3, & 4) 6 | 4 | 4 | 3 | 6 | 4 | 4 | 3 Structural I | 10d | 1-1/2 | 15/32 | 344 | 223 | 605700875 | 8159151220 | 87510051285 | 115012901395 | 8479801225 | 114012801707 | 122514071800 | 161018051952 19/32 | 344 | 223 | 670780965 | 8809901320 | 96511101405 | 125514401790 | 93710921350 | 123213851847 | 135015551967 | 175720152505 23/32 | 344 | 223 | 7308551050 | 95510701430 | 105012101525 | 136515651800 | 102211971470 | 133714972002 | 147016952135 | 191021902520 Sheathing and Single-Floor (DOC PS1 and PS2) | 10d | 1-1/2 | 15/32 | 344 | 223 | 525605765 | 7258151085 | 7658751130 | 101011051195 | 7358471070 | 101511401520 | 107012251582 | 141515471672 19/32 | 344 | 223 | 650755935 | 8609651290 | 93510801365 | 122513701485 | 91010571310 | 120513501805 | 131015121910 | 171519172080 23/32 | 344 | 223 | 7108251020 | 93510501400 | 102011751480 | 133514451565 | 99511551427 | 131014701960 | 142716452072 | 187020222190 Notes: a. See AWC SDPWS for the following: For general construction requirements see 4.2.7. For specific requirements see 4.2.8.1 for wood structural panel diaphragms. See Figure 4C for nailing diagrams. See Appendix A for common nail dimensions. b. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. c. See AWC SDPWS Table 4.2B for Case definitions. d. See AWC SDPWS Table 4.2B for the apparent shear stiffness values (Ga). e. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size.
( Ord. 25-5 , 11/25/2025 )
Ask a question about Santa Clarita law
Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.