§ 18.08.080: Section 2306.3 is Amended.

Section 2306.3 is amended to read as follows: 2306.3 Wood-frame shear walls. Wood-frame shear walls shall be designed and constructed in accordance with AWC SDPWS. Where Allowable Stress Design is used, Table 2306.3(4) may be applied. Application of Table 4.3A of AWC SDPWS shall include the following: 1. Wood structural panel thickness for shear walls shall not be less than 3/8 inch thick. When 3/8-inch or 7/16-inch thick panels are used, studs shall not be spaced at more than 16 inches on center. 2. The maximum unit shear capacities for 3/8 inch wood structural panels resisting seismic forces shall be 200 pounds per linear foot (plf) using ASD or 280 plf using LRFD. Exception: Other nominal unit shear capacities may be permitted if such values are substantiated by cyclic testing and approved by the Building Official. 3. Nails shall be placed not less than 1/2 inch in from the panel edges and not less than 3/8 inch from the edge of the connecting members for shear greater than 350 plf using ASD or 490 plf using LRFD. Nails shall be placed not less than 3/8 inch from panel edges and not less than 1/4 inch from the edge of the connecting members for shears of 350 plf or less using ASD or 490 plf or less using LRFD. 2306.3.1 Application of Table 4.3B of AWC SDPWS shall not be permitted. 2306.3.2 See section 2505.4 as amended for provisions regarding gypsum board and portland cement plaster shear walls. 2306.3.3 Shear walls using panels fastened with staples shall not be permitted. Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the Building Official. 2306.3.4 The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the AWC SDPWS.

( Ord. 25-5 , 11/25/2025 )

Ask a question about Santa Clarita law

Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.