§ 16.52.507: Fire protection water supplies.
(a) Fire flow. California Fire Code Section 507.3 is hereby amended to read: 507.3 Fire flow. Fire flow requirements for buildings or portions of buildings and facilities shall be determined in accordance with Appendix B. (b) Where required. California Fire Code Section 507.5.1 is hereby amended to read: 507.5.1 Where required. Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet (91.5 m) from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility of building, onsite fire hydrants and mains shall be provided where required by the fire code official. The location, number and type of hydrants shall be approved by the fire code official. (c) Hydrant for standpipe system. California Fire Code Section 507.5.1.1 is hereby amended to read: 507.5.1.1 Hydrant for standpipe system. Buildings equipped with a standpipe system installed in accordance with Section 905 shall have a hydrant within 50 feet (15 m) of the fire department connections on the same side of the road. Exception: The distance shall be permitted to exceed 50 feet (15 m) where approved by the fire code official. (d) Hydrant for automatic sprinkler system. California Fire Code Section 507.5.1.2 is hereby amended to read: 507.5.1.2 Hydrant for automatic sprinkler system. Buildings equipped with an automatic sprinkler system installed in accordance with Section 903 shall have a hydrant within 50 feet (15 m) of the fire department connections on the same side of the road. Exception: The distance shall be permitted to exceed 50 feet (15 m) where approved by the fire code official. (e) Obstruction. California Fire Code Section 507.5.4 is hereby amended to read: 507.5.4 Obstruction. Unobstructed access to fire hydrants and fire protection equipment shall be maintained at all times. The fire department shall not be deterred or hindered from gaining immediate access to fire protection equipment of fire hydrants. (f) Identification and marking. California Fire Code is hereby amended by adding Section 507.5.7 to read: 507.5.7 Identification and marking. Fire protection equipment and hydrants shall be clearly identified in a manner approved by the fire code official. All fire department connections, post indicator valves and on-site fire hydrants shall be painted an approved 'safety' yellow. Hydrant locations shall be identified by the installation of blue reflective markers.
( Ord. 3018-13 § 2 ; Ord. 3201-22 § 1 )
Ask a question about Sunnyvale law
Corpus searches the Sunnyvale sections it holds and shows the ones that match, with their citations. Free, no sign-in.