§ 16.52.903 — Automatic sprinkler systems
Code of Ordinances, City of Sunnyvale, California (includes legislation through Ord. No. 3260-26 adopted August 11, 2026) · Sunnyvale Code of Ordinances § 16.52.903
Corpus is an independent public-information project, not the official City of Sunnyvale website. Stable reference: corpuslaw.us/code/3014581d-7cb2-4e54-bfb4-c892eb5780bc
§ 16.52.903: Automatic sprinkler systems.
(a) Design criteria. California Fire Code Section 903.1.1.1 is hereby amended to read: 903.1.1.1 Design criteria. The following design criteria shall be applied for NFPA 13 and NFPA 13D fire sprinkler systems: 1. The design criteria shall be set at 10 percent below the hydraulic curve drawn from the available water supply. 2. A maximum flow velocity of 20 feet per second shall not be exceeded. 3. Where corrosive conditions are known to exist due to moisture or fumes from corrosive chemicals or both, special types of fittings, pipes and hangers that resist corrosion shall be used or a protective coating shall be applied to all unprotected exposed surfaces of the sprinkler system. 4. The minimum size water meter for NFPA 13D systems shall be 1″. (b) Residential sprinkler systems. California Fire Code Section 903.1 is hereby amended by adding Section 903.1.2 to read: 903.1.2 Residential sprinkler systems. Fire sprinkler systems in residential occupancies as required by California Residential Code Section R309 shall be regulated under the authority of the fire code official. (c) Where required. California Fire Code Section 903.2 is hereby amended to read: 903.2 Where required. Approved automatic sprinkler systems in new and existing buildings and structures shall be provided in the locations described in this Section or in Sections 903.2.1 through 903.2.12 and Sections 903.2.14 through 903.2.21, whichever is the more restrictive. Exception: Group S-2 or U occupancies used exclusively for vehicle parking and which meet all of the following: a. Noncombustible construction. b. Maximum building area not to exceed 5,000 square feet. c. Structure is open on three or more sides. d. Minimum of 10 feet separation from existing buildings unless area is separated by fire walls complying with California Building Code 706. For the purposes of this Section, firewalls and fire barriers used to separate building areas shall be constructed in accordance with the California Building Code and shall be without openings or penetrations. 1. | An automatic sprinkler system shall be provided throughout all new buildings and structures. Exception: Buildings and structures, other than group R-3 occupancies and townhouses that do not exceed 1,000 square feet of building area. 2. | An automatic sprinkler system shall be provided throughout existing buildings and structures less than 3,600 square feet, other than group R-3 occupancies and townhouses, when additions are made that increase the building area to 3,600 square feet or greater, or that create conditions described in Sections 903.2.1 through 903.2.12 and Sections 903.2.14 through 903.2.21. Exception: One-time additions to existing buildings that do not total more than 500 square feet of building area. 3. | An automatic sprinkler system shall be provided throughout existing buildings and structures 3,600 square feet or greater, other than group R-3 occupancies and townhouses, when any addition is made, or that create conditions described in Sections 903.2.1 through 903.212 and Sections 903.2.14 through 903.2.21. Exception: One-time additions to existing buildings that do not total more than 500 square feet of building area. 4. | An automatic sprinkler system shall be provided throughout existing buildings and structures 3,600 square feet or greater, other than group R-3 occupancies and townhouses, when alterations or repairs are made that are in excess of 50 percent of the existing building area within a 12-month period, or that create conditions described in Sections 903.2.1 through 903.2.12 and Sections 903.2.14 through 903.2.21 or Chapter 11. For the purposes of this chapter, alterations and repairs shall be determined by the fire code official and include, but not be limited to; changes in T-bar ceiling, changes in the means of egress system, extending travel distances that would otherwise require the addition of automatic fire sprinklers, and extended distances from fire apparatus access roads. 5. | An automatic sprinkler system shall be provided when there is any change in the character of occupancy or in the use of any existing building or structure 3,600 square feet or greater, when the fire code official determines the change would place the building into a more hazardous division of the same occupancy group, or into a different occupancy group, which constitutes a greater life safety exposure or increased fire risk.1,2 6. | An automatic sprinkler system shall be provided in all accessible combustible and noncombustible sub-floors, attic space, or areas above ceilings, which are greater than 6 inches (152.4 mm) in height and contain electrical or mechanical components, in a fire sprinklered structure. Exceptions: 1. | NFPA 13D systems shall comply with California Residential Code R309 and local standards. 2. | The fire code official may permit the use of smoke detection in lieu of fire sprinklers in noncombustible and non-assessable floor spaces and when construction materials do not exceed a flame spread rating of 25. 7. | An automatic sprinkler system shall be provided throughout all new basements regardless of size, and throughout existing basements that are expanded by more than 50 percent. 8. | Automatic sprinkler protection shall be provided in all storage areas that are within 5 feet (3,048 mm) of the exterior building walls, roof overhangs, canopies or constitute an exposure to adjacent property. Such sprinklers may be connected to the domestic water, supply if the structure is not otherwise required to be fire sprinklered. Systems using domestic water supply shall not be less than 1-inch (25.4-mm) diameter pipe. Sufficient coverage of the area shall be provided and an approved accessible shut-off valve is to be provided for each room or area. Where valves are subject to possible vandalism, an approved means of securing the valve in the open position shall be provided. Where there are no ceilings, an 18 square inch (11,613 square mm) heat baffle shall be provided not more than 6 inches (152.4 mm) above the sprinkler head. All exposed piping shall be brazed copper or steel. 1 | Life Safety – Shall include, but not limited to: increased occupant load, public assembly areas, public meeting areas, churches, indoor amusement attractions, buildings with complex exiting systems due to increased occupant loads, large schools/day-care facilities, large residential care facilities housing non-ambulatory clients. 2 | Fire Risks – Shall include, but not limited to: high-piled combustible storage, woodworking operations, hazardous operations using hazardous materials, increased fuel loads (storage of moderate to highly combustible materials), increased sources of ignition (welding, automotive repair with the use of flammable liquids and open flames). (d) Chemical Fume Hood Fire Protection. California Fire Code Section 903.2 is hereby amended by adding Section 903.2.11.7 to read: 903.2.11.7 Chemical Fume Hood Fire Protection. Approved automatic fire extinguishing systems shall be provided in chemical fume hoods. Exception: Internal fire protection is not required where quantities of flammable liquids in use or storage within the cabinet do not exceed 500 ml. (e) NFPA 13 sprinkler systems. California Fire Code Section 903.3.1.1 is hereby amended to read: 903.3.1.1 NFPA 13 sprinkler systems. Where the provisions of this code require that a building or portion thereof be equipped throughout with an automatic sprinkler system in accordance with this section, sprinklers shall be installed throughout in accordance with NFPA 13 as amended in Chapter 80 except as provided in Section 903.3.1.1.1 through 903.3.1.1.3. Exception: For new buildings having no designated use or tenant, the minimum sprinkler design density shall be Ordinary Hazard Group 2. (f) NFPA 13R sprinkler systems. California Fire Code Section 903.3.1.2 is hereby amended to read: 903.3.1.2 NFPA 13R sprinkler systems. NFPA 13R sprinkler systems are not permitted. Additional references to NFPA 13R systems in this Section are not applicable. (g) Floor control valves. California Fire Code Section 903.3.10 is hereby amended to read: 903.3.10 Floor control valves. Floor control valves and waterflow detection assemblies shall be installed at each floor where any of the following occur: 1. | Buildings that are two or more stories in height. 2. | Building that are two or more stories below the highest level of fire department vehicle access. Exception: Group R-3 and R3.1 occupancies floor control valves and waterflow detection assemblies shall not be required. (h) Riser shut-off valve. California Fire Code Section 903.3 is hereby amended by adding Section 903.3.11 to read: 903.3.11 Riser shut-off valve. Each individual riser shall be equipped with a post indicator valve located outside the structure. The post indicator valve locations shall be determined upon plan review. Post indicator valves shall be a minimum of 20 feet (6,096 mm) from any building openings. All valves shall be secured with a non-case-hardened lock. For single-use fire laterals, a backflow preventer may be used in lieu of a post indicator valve. (i) Corrosion-resistant paint. California Fire Code Section 903.3.12 is hereby amended to read: 903.3.12 Corrosion-resistant paint. Throughout open parking garages and all areas with exposed exterior sprinkler piping, steel pipe shall be properly protected from corrosion by painting the pipe with corrosion-resistant paint. (j) Floor control valves. California Fire Code Section 903.4.4 is hereby amended to read: 903.4.4 Floor control valves. Approved supervised indicating control valves shall be provided at the point of connection to the riser on each floor.
( Ord. 3018-13 § 2 ; Ord. 3101-16 § 1 ; Ord. 3148-19 § 1 ; Ord. 3201-22 § 1 ; Ord. 3247-25 , 10/21/2025 )
Ask a question about Sunnyvale law
Corpus searches the Sunnyvale sections it holds and shows the ones that match, with their citations. Free, no sign-in.