§ 16.52.4120 — Means of egress

Code of Ordinances, City of Sunnyvale, California (includes legislation through Ord. No. 3260-26 adopted August 11, 2026) · Sunnyvale Code of Ordinances § 16.52.4120

Corpus is an independent public-information project, not the official City of Sunnyvale website. Stable reference: corpuslaw.us/code/f7a09771-95f1-4ce1-843c-0df5c535f90f

§ 16.52.4120: Means of egress.

(a) Stairways required. California Fire Code Section 3307.1.2 is hereby amended to read: [BE] 3307.1.2 Stairways required. Each level above the first story in new multi-story buildings that require two exit stairways shall be provided with at least two usable exit stairways after the floor decking is installed. The stairways shall be continuous and discharge to grade level. Stairways serving more than two floor levels shall be enclosed (with openings adequately protected) after exterior walls/windows are in place. Exit stairs in new and in existing, occupied buildings shall be lighted and maintained clear of debris and construction materials at all times. Exception: For new multi-story buildings, one of the required exit stairs may be obstructed on not more than two contiguous floor levels for the purposes of stairway construction (i.e., installation of gypsum board, painting, flooring, etc.). (b) Required means of egress. California Fire Code Section 3307.1.4 is hereby amended to read: 3307.1.4 Required means of egress. All new buildings under construction shall have at least one unobstructed means of egress. All means of egress shall be identified in the prefire plan as outlined in Section 3303.1.

( Ord. 3018-13 § 2 ; Ord. 3101-16 § 1 ; Ord. 3148-19 § 1 ; Ord. 3201-22 § 1 ; Ord. 3247-25 , 10/21/2025 )

Ask a question about Sunnyvale law

Corpus searches the Sunnyvale sections it holds and shows the ones that match, with their citations. Free, no sign-in.