§ 16.52.5004: Hazardous materials: storage.

(a) Spill control for hazardous materials liquids. California Fire Code Section 5004.2.1 is hereby amended to read: 5004.2.1 Spill control for hazardous material liquids. Rooms, buildings or areas used for storage of hazardous material liquids shall be provided with spill control to prevent the flow of liquids to adjoining areas. Floors in indoor locations and similar surfaces in outdoor locations shall be constructed to contain a spill from the largest single vessel by one of the following methods: 1. Liquid-tight sloped or recessed floors in indoor locations or similar areas in outdoor locations. 2. Liquid-tight floors in indoor locations or similar areas in outdoor locations provided with liquid-tight raised or recessed sills or dikes. 3. Sumps and collection systems, including containment pallets in accordance with Section 5004.2.3. 4. Other approved engineered systems. Except for surfacing, the floors, sills, dikes, sumps and collection systems shall be constructed of noncombustible material, and the liquid-tight seal shall be compatible with the material stored. When liquid-tight sills or dikes are provided, they are not required at perimeter openings having an open-grate trench across the opening that connects to an approved collection system. (b) Incompatible materials. California Fire Code Section 5004.2.2.2 is hereby amended to read: 5004.2.2.2 Incompatible materials. Incompatible materials shall be separated from each other in independent secondary containment systems. (c) Containment pallets. California Fire Code Section 5004.2.3 is hereby amended to read: 5004.2.3 Containment pallets. Combustible containment pallets shall not be used inside buildings to comply with Section 5004.2 where the individual container capacity exceeds 55 gallons (208 L) or an aggregate capacity of multiple containers exceeds 1,000 gallons (3,785 L) for liquids or where the individual container capacity exceeds 550 pounds (250 kg) or an aggregate of multiple containers exceeds 10,000 pounds (4,540 kg) for solids. Where used as an alternative to spill control and secondary containment for outdoor storage in accordance with the exception in Section 5004.2, containment pallets shall comply with all of the following: 1. A liquid-tight sump accessible for visual inspection shall be provided; 2. The sump shall be designed to contain not less than 66 gallons (250L); 3. Exposed surfaces shall be compatible with material stored; and 4. Containment pallets shall be protected to prevent collection of rainwater within the sump of the containment pallet.

( Ord. 3018-13 § 2 ; Ord. 3101-16 § 1 ; Ord. 3148-19 § 1 )

Ask a question about Sunnyvale law

Corpus searches the Sunnyvale sections it holds and shows the ones that match, with their citations. Free, no sign-in.