§ 16.52.5003: Hazardous materials: general requirements.
(a) Highly toxic and toxic gases and similarly used or handled materials. California Fire Code Section 5003.1.3.1 is hereby amended to read: 5003.1.3.1 Highly toxic and toxic gases and similarly used or handled materials. The storage, use and handling of highly toxic and toxic gases in amounts exceeding Table 6004.2.1.4 shall be in accordance with this chapter and Chapter 60. Any highly toxic or toxic material that is used or handled as a gas or vapor shall be in accordance with the requirements for highly toxic or toxic gases. (b) Spill control and secondary containment requirements. California Fire Code Section 5003 is hereby amended by adding Section 5003.1.5 to read: 5003.1.5 Additional spill control and secondary containment requirements. In addition to the requirements set forth in Section 5004.2, an approved containment system is required for any quantity of hazardous materials that are liquids or solids at normal temperature, and pressure (NTP) where a spill is determined to be a plausible event and where such an event would endanger people, property or the environment. The approved containment system may be required to include a combination of spill control and secondary containment meeting the design and construction requirements set forth in Section 5004.2. (c) Design and construction. California Fire Code Section 5003.2.2.1 is hereby amended to read: 5003.2.2.1 Design and construction. Piping, tubing, valves, fittings and related components used for hazardous materials shall be in accordance with the following: 1. Piping, tubing, valves, fittings and related components shall be designed and fabricated from materials compatible with the material to be contained and shall be of adequate strength and durability to withstand the pressure, structural and seismic stress, and exposure to which they are subject. 2. Piping and tubing shall be identified in accordance with ASME A13.1 and the Santa Clara County Fire Chiefs' Marking Requirements and Guidelines for Hazardous Materials and Hazardous Waste to indicate the material conveyed. 3. Readily accessible manual valves or automatic remotely activated fail-safe emergency shutoff valves shall be installed on supply piping and tubing at the following locations: 1. The point of use. 2. The tank, cylinder or bulk use. 4. Manual emergency shutoff valves and controls for remotely activated emergency shutoff valves shall be identified and the location shall be clearly visible accessible and indicated by means of a sign. 5. Backflow prevention or check valves shall be provided when the backflow of hazardous materials could create a hazardous condition or cause the unauthorized discharge of hazardous materials. 6. Where gases or liquids having a hazard ranking of: Health hazard Class 3 or 4 Flammability Class 4 Instability Class 3 or 4 in accordance with NFPA 704 are carried in pressurized piping above 15 pounds per square inch gauge (psig)(103 KPa), an approved means of leak detection, emergency shutoff or excess flow control shall be provided. Where the piping originates from within a hazardous material storage room or area, the excess flow control shall be located within the storage room or area. Where the piping originates from a bulk source, the excess flow control shall be located as close to the bulk source as practical. Exceptions: 1. | Piping for inlet connections designed to prevent backflow. 2. | Piping for pressure relief devices. 7. Secondary containment or equivalent protection from spills or leaks shall be provided for piping for highly toxic and toxic corrosive gases above threshold quantities listed in Tables 6004.2.1 and for all liquid hazardous materials regulated by this code. Secondary containment includes, but is not limited to double walled piping. Exceptions: 1. | Secondary containment is not required for toxic corrosive gases if the piping is constructed of inert materials. 2. | Piping under sub-atmospheric conditions if the piping is equipped with an alarm and fail-safe-to-close valve activated by a loss of vacuum. 8. Expansion chambers shall be provided between valves whenever the regulated gas may be subjected to thermal expansion. Chambers shall be sized to provide protection for piping and instrumentation and to accommodate the expansion of regulated materials. (d) Additional regulation for supply piping for health hazard materials. California Fire Code Section 5003.2.2.2 is hereby amended to read: 5003.2.2.2 Additional regulation for supply piping for health hazard materials. Supply piping and tubing for gases and liquids having a health hazard ranking of 3 or 4 shall be in accordance with ASME B31.3 and the following: 1. Piping and tubing utilized for the transmission of highly toxic, toxic or highly volatile corrosive liquids and gases shall have welded or brazed connections throughout except for connections within an exhausted enclosure if the material is a gas, or an approved method of drainage or containment is provided for connections if the material is a liquid. 2. Piping and tubing shall not be located within corridors, within any portion of a means of egress required to be enclosed in fire-resistance-rated construction or in concealed spaces in areas not classified as Group H Occupancies. Exception: Piping and tubing within the space defined by the walls of corridors and the floor or roof above or in concealed space above other occupancies when installed in accordance with Section 415.8.6.3 of the California Building Code as required for Group H, Division 5 Occupancies. 3. All primary piping for highly toxic, toxic and moderately toxic gases shall pass a helium leak test of 1 x 10-9 cubic centimeters per second where practical, or shall pass testing in accordance with an approved, nationally recognized standard. Tests shall be conducted by a qualified "third party" not involved with the construction of the piping and control systems. (e) Equipment, devices and systems requiring testing. California Fire Code Section 5003.2.9.1 is hereby amended to read: 5003.2.9.1 Equipment, devices and systems requiring testing. The following equipment, systems and devices shall be tested in accordance with Sections 5003.2.9 and 5003.2.9.2. 1. Gas detection systems, alarms and automatic emergency shutoff valves required by Section 6004.2.2.10 for highly toxic and toxic gases. 2. Limit control systems for liquid level, temperature and pressure required by Sections 5003.2.7, 5004.8 and 5005.1.4. 3. Emergency alarm systems and supervision required by Sections 5004.9 and 5005.4.4. 4. Monitoring and supervisory systems required by Sections 5004.10 and 5005.1.6. 5. Manually activated shutdown controls required by Section 6403.1.1.1 for compressed gas systems conveying pyrophoric gases. 6. Gas detection systems, alarms and automatic emergency shutoff valves installed in repair garages for vehicles fueled by lighter-than-air fuels in accordance with Section 2311.8. (f) 5003.3.1 Unauthorized discharges. California Fire Code Section 5003.3.1 is hereby amended to read: 5003.3.1 Unauthorized discharges. In the event hazardous materials are released in quantities reportable under state, federal or local regulations or when there is release or a threatened release that presents a threat to health, property or the environment, the fire code official shall be notified immediately in an approved manner and the following procedures required in accordance with Sections 5003.3.1.1 through 5003.3.1.4. (g) 5003.5.2 Ventilation ducting. California Fire Code Section 5003.5.2 is hereby amended to read: 5003.5.2 Ventilation ducting. Ducts venting hazardous materials operations shall be labeled with the hazard class of the material being vented and the direction of flow. (h) "H" Occupancies. California Fire Code Section 5003 is hereby amended by adding Section 5003.5.3 to read: 5003.5.3 "H" Occupancies. In "H" occupancies, all piping and tubing may be required to be identified when there is any possibility of confusion with hazardous materials transport tubing or piping. Flow direction indicators are required. (i) Fire extinguishing systems for workstations dispensing, handling or using hazardous materials. California Fire Code Section 5003 is hereby amended by adding Section 5003.9.11 to read: 5003.9.11 Fire extinguishing systems for workstations dispensing, handling or using hazardous materials. Combustible and non-combustible workstations, which dispense, handle or use hazardous materials, shall be protected by an approved automatic fire extinguishing system in accordance with Section 2703.10. Exception: Internal fire protection is not required for Biological Safety Cabinets that carry NSF/ANSI certification where quantities of flammable liquids in use or storage within the cabinet do not exceed 500 ml. (j) 5003.10.4 Elevator transport. California Fire Code Section 5003.10.4 is hereby amended to read: 5003.10.4 Elevators utilized to transport hazardous materials. 5003.10.4.1 When transporting hazardous materials, elevators shall have no other passengers other than in the individual(s) handling the chemical transport cart. 5003.10.4.1.1 When transporting cryogenic or liquefied compressed gases, there shall be no occupants in the elevator. 5003.10.4.2 Hazardous materials liquid containers shall have a maximum capacity of 20 liters (5.26 gal). 5003.10.4.3 Toxic, highly toxic and asphyxiant gases shall be limited to a container of a maximum water capacity of 1 lb. 5003.10.4.4 When transporting cryogenic or liquefied compressed gases, means shall be provided to prevent the elevator from being summoned to other floors.
( Ord. 3018-13 § 2 ; Ord. 3044-14 § 5 ; Ord. 3101-16 § 1 ; Ord. 3148-19 § 1 ; Ord. 3201-22 § 1 ; Ord. 3247-25 , 10/21/2025 )
Ask a question about Sunnyvale law
Corpus searches the Sunnyvale sections it holds and shows the ones that match, with their citations. Free, no sign-in.