§ 16.52.8103: Minimum specifications.

(a) Turning radius. Appendix D Section D103.3 of the 2024 International Fire Code is hereby amended to read: D103.3 Turning radius. The minimum turning radius of a fire apparatus access road shall be in accordance with Section 503.2.4. and the following: 1. 30 feet minimum inside curb radius where access roads less than 26 feet wide are provided, and 2. 27 feet minimum inside curb radius where access roads 26 feet wide or greater are provided. (b) Dead ends. Appendix D Section D103.4 of the 2024 International Fire Code is hereby amended to read: D103.4 Dead ends. Dead-end fire apparatus access roads in excess of 150 feet (45,720 mm) shall be provided with width and turnaround provisions in accordance with Table D103.4 and Figure D103.4. TABLE D103.4 REQUIREMENTS FOR DEAD-END FIREAPPARATUS ACCESS ROADS [Table D103.4 not reproduced here. No amendments are proposed for the table.] (c) Dead end fire apparatus access road turnaround. Appendix D Section D103.4 of the 2024 International Fire Code is hereby amended by adding Figure D103.1 to read: FIGURE D103.1DEAD-END FIRE APPARATUS ACCESSROAD TURNAROUND [Figure D103.1 not reproduced here. No amendments are proposed for the Figure.] (d) Fire apparatus access road gates. Appendix D Section D103.5 of the 2024 International Fire Code is hereby amended to read: D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. The minimum gate width shall be 20 feet (6096 mm). Exception: Access roads serving not more than two Group R-3 or Group U occupancies shall have an unobstructed width of not less than 12 feet. 2. Gates shall be of the swinging or sliding type. 3. Construction of gates shall be of materials that allow manual operation by one person. 4. Gate components shall be maintained in an operative condition at all times and replaced or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the key(s) to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval by the fire code official. 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates intended for automatic operation shall be designed, constructed and installed to comply with the requirements of ASTM F 2200. (e) Roads 12 to 26 feet in width. Appendix D Section D103.6.1 of the 2024 International Fire Code is hereby amended to read: D103.6.1 Roads more than 26 feet in width. Fire apparatus access roads 12 to 26 feet wide (6,096 to 7,925 mm) shall be posted on both sides as a fire lane. (f) Roads more than 26 feet in width. Appendix D Section D103.6.2 of the 2024 International Fire Code is hereby amended to read: D103.6.2 Roads more than 26 feet in width. Fire apparatus access roads more than 26 feet wide (7,925 mm) to 32 feet wide (9,754 mm) shall be posted on one side of the road as a fire lane.

( Ord. 3018-13 § 2 ; Ord. 3101-16 § 1 ; Ord. 3148-19 § 1 ; Ord. 3201-22 § 1 ; Ord. 3247-25 , 10/21/2025 )

Ask a question about Sunnyvale law

Corpus searches the Sunnyvale sections it holds and shows the ones that match, with their citations. Free, no sign-in.