§ 5.44.110: System—Design.

(a) The system will be designed to provide video carrier levels of not less than two thousand microvolts (0 dbmv) as measured at the input terminals of each subscriber's TV receiver. (b) The system and all equipment will be designed and rated for twenty-four hours per day continuous operation. (c) The system will be designed to provide an arterial or approved underground, conduit-contained trunk cable which shall be tapped to feed signals directly to subscriber terminals. (d) The distribution system will be designed in conjunction with the aforementioned trunk system to provide a tappable coaxial cable system, allowing the use of directional taps necessary to make "mid-span" connections for the purpose of providing signals to standard receivers connected to the system. (e) The system signal-to-noise ratio will be not less than forty-six db. (f) The hum-modulation of picture signals will be less than five percent. (g) The system shall use impedance matched components having a VSWR (voltage standing wave ratio) of not more than 1.4.

( Ord. 1422 § 11, 1968 )