For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.44.200 — Subscriber service drops

Code of Ordinances, City of Sunnyvale, California (includes legislation through Ord. No. 3260-26 adopted August 11, 2026) · Sunnyvale Code of Ordinances § 5.44.200

Corpus is an independent public-information project, not the official City of Sunnyvale website. Stable reference: corpuslaw.us/code/1db77e1a-0718-4c60-8ca5-16a76333d27a

§ 5.44.200: Subscriber service drops.

(a) A single entry cable will be installed for each building with suitable distribution devices which will divide the signal for distribution to multiple receivers if such multiple connections are required. (b) The CATV system attachment to a building will have a clearance from power and telephone attachments of at least twelve inches. The same clearance will apply along the length of the building run when the CATV system cable parallels power and telephone service wires. (c) The CATV system service drop will not enter the building through the entrance hole or tube used for entrance of telephone or power service wires. (d) Cable will enter the building through a hole that has been suitably covered and weatherproofed. Cable will run from the point of entrance to the terminal outlet without the need for conduit. Suitable clamps or staples for the attachment of the coaxial cable to floor joints or wall studs will be used. (e) Receiver isolation or tapoff units will be installed utilizing the shortest possible distance between building and feeder distribution line. A spacing of not less than four feet will be kept between such receiver isolation units. These units will provide means to secure the bonding of messenger strand, drop support wire and outer conductors of feeder as well as of house drop cable. (f) All house drops will be supported by suitable strand or messenger wire (109 steel line wire or suitable equivalent and lashed with forty-five thousandths inch stainless steel lashing wire). Fire "8" integral messenger RG-59U is acceptable under this provision. (g) Grounding devices will be employed to ground the outer conductor of the subscriber's drop coaxial cable in such manner as to insure that the outer conductor of this cable is at ground potential throughout its entire length. Both the shield and center conductor will isolate DC to low frequency AC from the input terminals of the receivers connected to the system by blocking capacitors or transformers.

( Ord. 1422 § 20, 1968 )

Ask a question about Sunnyvale law

Corpus searches the Sunnyvale sections it holds and shows the ones that match, with their citations. Free, no sign-in.