§ 815.3.020: Scope and applicability.

The provisions of this Chapter shall apply to any existing Concrete Building determined by the Building Official to have been built under building code standards enacted before the 1979 Uniform Building Code with local amendments adopted on April 28th, 1981. EXCEPTIONS: This Chapter shall not apply to the following structure types: (1) Concrete shear wall structures with flexible diaphragms. (2) Single story structures, unless the lateral system contains concrete moment frame elements. (3) Wood structures over concrete podium unless the podium contains a Major Deficiency as specified in section 815.3.050.a. (4) Buildings with a steel lateral resisting system encased in concrete. Notwithstanding any provision of the Building Code, compliance with this Chapter shall not require existing electrical, plumbing, mechanical or fire-safety systems to be altered to comply with existing code unless they constitute a hazard to life or property as determined by Building Official.