For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 815.3.030 — Definitions

Municipal Code, City of Torrance, California · Torrance Municipal Code § 815.3.030

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/99706199-76a3-4f65-b1e2-e3fd2e66d499

§ 815.3.030: Definitions.

Notwithstanding the applicable definitions, symbols and notations in the Building Code, the following definitions shall apply for the purposes of this Chapter: a) BUILDING CODE Is the current Building Code of the City of Torrance. b) CAPTIVE COLUMN DEFICIENCY OCCURS When there are columns at a level with height/depth ratios less than 50% of the nominal height/depth ratio of the typical columns at the level. c) CONCRETE BUILDING Is a building having concrete floors and/or roofs, either with or without beams, and a lateral resisting system composed of concrete walls and/or concrete frames with or without masonry infills, or any combination thereof. Lift-slab buildings shall be considered as part of the concrete buildings with or without a concrete lateral resisting system. d) OWNER OR BUILDING OWNER Is the individual(s), agent, firm, corporation, or entity having legal possession, equitable interest in the property, or rights to sanction evaluation or retrofit of a building. e) HISTORICAL BUILDING Is any building designated, or currently in the process of being designated, as a "qualified historical building" as defined in Part 8, Title 24 of the California Code of Regulations. f) LOAD PATH DEFICIENCY OCCURS When a structure does not contain a complete, well defined lateral load path, including structural elements and connections, that serves to transfer the inertial forces associated with the mass of all elements of the building to the foundation. g) MASONRY INFILL Is the unreinforced or reinforced masonry wall construction within a reinforced concrete frame. h) OWNER OF BUILDING OWNER Is the individual(s), agent, firm, corporation, or entity having legal possession, equitable interest in the property, or rights to sanction evaluation or Retrofit of a building. i) RETROFIT Is an improvement of the lateral force resisting system by alteration of existing structural elements or addition of new structural elements. j) SOFT STORY DEFICIENCY OCCURS When the stiffness of the seismic-force-resisting system in any Story is less than 70% of the seismic-force-resisting system in an adjacent Story above or less than 80% of the average seismic-force system stiffness of the three stories above. k) STORY Is as defined in the Building Code, but includes any basement or underfloor space of a building with cripple walls exceeding four feet in height. l) STORY STRENGTH Is the total strength of all seismic-resisting elements sharing the same story shear in the direction under consideration. m) TORSION DEFICIENCY OCCURS When the estimated distance between the Story center of mass and the Story center of rigidity is more than 20% of the building width in either plan dimension. n) VERTICAL IRREGULARITY DEFICIENCY EXISTS When one or more vertical elements in the seismic-force-resisting system are not continuous to the foundation. o) WEAK STORY DEFICIENCY OCCURS When the sum of the shear strengths of the seismic-force-resisting system in any Story in each direction is less than 80% of the strength in the adjacent Story above.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.