§ 97.9.35: Fence tests.
Strength tests, impact tests or other tests and Engineering calculations may be required on materials and components of oil site fences in accordance with the procedures and methods set forth below: a) Chainlink fence fabric shall meet the minimum breaking strength shown on Table 1. Specimens to establish conformance to this requirement shall be chosen from individual pickets comprising a section of the fence fabric. The specimens shall be of sufficient length so as to be firmly gripped in the testing machine after straightening. The actual gage length (distance between jaws) of the specimen shall be limited to the undeformed length of wire between the two adjacent straightened bends. TABLE 1 Breaking Strength Size Coated Wire | Nominal Diameter of Coated Wire | Breaking. Strength Min. Gage (mm) | in. | mm | lbf | N 6(4.11) | 0.192 | 4.88 | 1736 | 7720 9(2.19) | 0.148 | 3.76 | 1032 | 4592 11(2.30) | 0.120 | 3.05 | 680 | 3024 b) Zinc coating for the various gages of wire composing the strands of the barbed wire shall weigh eighty (80) percent of the weight values for the particular class of coating specified as prescribed in Table 2. TABLE 2 Minimum Weight of Coating on Zinc-Coated Barbed Wire Size Steel Wire Gage | Nominal Diameter of Zinc-Coated Wire in. | Minimum Weight of Coating oz/ft. (kg/m2) of Uncoated Wire Surface. (mm) | Class 1 | Class 2 | Class 3 No. 12-½ | 0.099 (2.51) | 0.30(0.092) | 0.50(0.153) | 0.80(0.244) No. 14 | 0.080 (2.03) | 0.25(0.076) | 0.45(0.137) | 0.65(0.198) No. 16 | 0.0625(1.57) | 0.15(0.046) | 0.35(0.107) | 0.60(0.153) c) Posts and top rails shall meet the outside diameter, wall thickness and weight requirements prescribed in Table 3. Posts and top rails shall withstand eighty (80) percent of the test pressures prescribed in Table 3. TABLE 3 Dimensions, Weights, and Test Pressures for Pipe Weight | Test Pressure Size | Outside Diameter | Wall Thickness | Plain Ends | Threads and Couplings | Butt Welded | Electric Resistance Welded in. | in. | mm | in. | mm | lb/ft | kg/m | lb/ft | kg/m | psi | Mpa | psi | MPa ⅛ | 0.405 | 10.3 | 0.068 | 1.7 | 0.24 | 0.4 | 0.24 | 0.4 | 700 | 4.83 | 700 | 4.83. ¼ | 0.540 | 13.7 | 0.088 | 2.2 | 0.42 | 0.6 | 0.42 | 0.6 | 700 | 4.83 | 700 | 4.83. ⅛ | 0.675 | 17.1 | 0.091 | 2.3 | 0.57 | 0.8 | 0.57 | 0.8 | 700 | 4.83 | 700 | 4.83. ½ | 0.840 | 21.3 | 0.109 | 2.8 | 0.85 | 1.3 | 0.85 | 1.3 | 700 | 4.83 | 700 | 4.83. ¼ | 1.050 | 26.7 | 0.113 | 2.9 | 1.13 | 1.7 | 1.13 | 1.7 | 700 | 4.83 | 700 | 4.83. 1 | 1.315 | 33.4 | 0.133 | 3.4 | 1.68 | 2.5 | 1.68 | 2.5 | 700 | 4.83 | 700 | 4.83. 1-¼ | 1.660 | 42.1 | 0.140 | 3.6 | 2.27 | 3.4 | 2.28 | 3.4 | 1000 | 6.89 | 1000 | 6.89. 1-½ | 1.900 | 48.3 | 0.145 | 3.7 | 2.72 | 4.0 | 2.73 | 4.1 | 1000 | 6.89 | 1000 | 6.89. 2 | 2.375 | 60.3 | 0.154 | 3.9 | 3.65 | 5.4 | 3.68 | 5.5 | 1000 | 6.89 | 1000 | 6.89. 2-½ | 2.875 | 73.0 | 0.203 | 5.2 | 5.79 | 8.6 | 5.82 | 8.7 | 1000 | 6.89 | 1000 | 6.89. 3 | 3.500 | 88.9 | 0.216 | 5.5 | 7.58 | 11.3 | 7.62 | 11.4 | 1000 | 6.89 | 1000 | 6.89. 3-½ | 4.000 | 101.6 | 0.226 | 5.7 | 9.11 | 13.6 | 9.20 | 13.7 | 1200 | 8.27 | 1200 | 8.27. 4 | 4.500 | 114.3 | 0.237 | 6.0 | 10.79 | 16.1 | 10.89 | 16.2 | 1200 | 8.27 | 1200 | 8.27. 5 | 5.563 | 141.3 | 0.258 | 6.6 | 14.62 | 21.8 | 14.81 | 22.1 | ’ | ’ | 1200 | 8.27. 6 | 6.625 | 168.3 | 0.280 | 7.1 | 18.97 | 28.3 | 19.18 | 28.6 | ’ | ’ | 1200 | 8.27.
[Added by Ord. 2748 ]
Ask a question about Torrance law
Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.