§ 13.22.190: Protective measures.
The following provisions are intended to protect the city's potable water supplies against actual, undiscovered, unauthorized, or potential cross-connections to the user's recycled water system. These provisions are in addition to, not in lieu of, the controls and requirements of other regulatory agencies. A. Approved backflow prevention devices on the city's potable water services to the use area as required in these provisions, shall be provided, installed, tested, and maintained according to Chapter 13.12. These devices shall be located on the property served immediately downstream of the meter. All devices shall be readily accessible for testing and maintenance and no device shall be submerged at any time. B. When a request for recycled water service is initiated, the applicant must provide sufficient information, including plumbing and building plans, for determination of the level of backflow protection required. Proper backflow protection, determined by the city and other regulatory agencies, shall then be installed and tested according to Chapter 13.12 before recycled water service is provided. C. Each time there is a change of user on any commercial or industrial premises, the owner or user shall notify the city immediately for reassessing the required level of protection of the potable water supply. In addition, any alterations to the user's existing on-site recycled water facilities that may affect the required potable water protection, the city must be immediately informed. D. The city and representatives of any governing agencies at their discretion may inspect any property provided with recycled water service by the city. The inspection shall serve to determine if any actual or potential cross-connections exist. The owner or user shall provide full cooperation in facilitating the inspection. E. When protection is required by the administrator, an approved backflow protection device for potable water supplies shall be provided as follows: 1. Each water service connection that supplies potable water to a premises having an auxiliary water supply (including recycled water) that is not accepted as a potable source by the city and/or is not approved for potable use by the DPH, shall be protected against backflow from the premises into the city potable water system. 2. Each water service connection supplying potable or recycled water to a premises on which any substance is handled in such a fashion as to permit entry into the city water systems (potable or recycled) from the premises shall be protected against backflow. This shall include, but not limited to, the handling of fertilizers, process waters, waters originating from any of the city water systems that have been subject to deterioration in quality, and agricultural use. 3. The city's approved backflow devices shall be installed where premises have complex piping arrangement that is vulnerable to be at risk of having a cross-connection or where not all portions of the premises are readily accessible for inspection. 4. Backflow protection shall be required at premises where there has been a history of cross-connections being established. F. Additional Protective Measures. 1. Water meters used for recycled water service shall be tagged or purple color-coded (color pantone 512 or 522), or otherwise distinguished as such per AWWA standards. These meters shall not be interchanged or used for potable water service after repairs and/or meter testing has been performed. 2. The city may conduct a periodic inspection of the recycled water facilities to determine if all identifying items are still clearly discernable. Any items or equipment failing to pass such inspection shall be immediately replaced, repaired or refurbished as needed, by the user. These items include: a. Warning tags or tapes; b. Painted surfaces; c. Identification tape; d. Covers, caps, signs; and e. Other items that indicate recycled water is being used. 3. To determine the existence of any cross-connections or backflow conditions into the potable water system, periodic testing by DPH approved methods will be performed by the city and/or other regulatory agencies.
( Ord. 1839 § 1, 2009 )
Ask a question about Upland law
Corpus searches the Upland sections it holds and shows the ones that match, with their citations. Free, no sign-in.