Sec. 23-247. - Cross-connection control program definitions.
The following definitions apply to Chapter 23, Article III, Division 1. Approved shall mean accepted by the director of public works as meeting an applicable specification stated or cited in this article, or as suitable for the proposed use. Approved backflow prevention device shall mean a device which has passed laboratory and field evaluation tests performed by a recognized testing organization which demonstrated its competency to perform such test to the California Department of Health Services. Auxiliary water supply shall mean any water supply on or available to the premises other than the purveyor's approved public potable water supply. These auxiliary waters may include water from another purveyor's public potable water supply or any natural source(s) such as well, spring, river, stream, harbor, etc., "used water" or industrial fluids. These waters may be objectionable and constitute an unacceptable water source over which the water purveyor does not have sanitary control. Backflow shall mean the reversal of the normal flow of water caused by either backpressure or back-siphonage. Backflow preventor shall mean a device or means designed to prevent backflow or back-siphonage, including but not limited to the following: (1) Air gap. The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet water supply to a tank, plumbing fixture, or other device and the flood level rim of said vessel. An approved air gap shall be at least double the diameter of the supply pipe, measured vertically, above the top of the rim of the vessel; and in no case less than one (1) inch when an air gap is used at the service connection to prevent the contamination or pollution of the public potable water system. (2) Reduced pressure principle device. An assembly to two (2) independently operating approved check valves with an automatically operating differential relief valve between the two (2) check valves, tightly closing shut-off valves on either side of the check valves, plus properly located test cocks for testing of the check and relief valves. The entire assembly shall meet the design and performance specifications and approval of a recognized and city-approved testing agency for backflow prevention assemblies. The device shall operate to maintain the pressure in the zone between the two (2) check valves at a level less than the pressure on the public water supply side of the device and at cessation of the normal flow, the pressure on the public water supply side of the device. In case of leakage of either of the check valves, the differential relief valve shall operate to maintain the reduced pressure in the zone between the check valves by discharging to the atmosphere. When the inlet pressure is two (2) pounds per square inch or less, the relief valve shall open to the atmosphere. To be approved, these devices must be readily accessible for in-line maintenance and testing and be installed in a location where no part of the assembly will be submerged. (3) Double-check valve assembly. An assembly of two (2) independently operating approved check valves with tightly closing shut-off valves on each side of the check valves, plus properly located test cocks for the testing of each check valve. The entire assembly shall meet the design and performance specifications and approval of a recognized and city-approved testing agency for backflow prevention devices. To be approved, these devices must be readily accessible for in-line maintenance and testing. Backpressure shall mean the flow of water or other liquids, mixtures or substances under pressure into the distributing pipes of a potable water supply system from any source or sources other than its intended sources. Back-siphonage shall mean the flow of water or other liquids, mixtures or substances into the distributing pipes of a potable water supply system from any source other than its intended source caused by the sudden reduction of pressure in the potable water supply system. Contamination shall mean an impairment of the quality of the potable water by sewage, industrial fluids or waste liquids, compounds or other materials to a degree which creates an actual hazard to the public health through poisoning or through the spread of disease. Cross-connection shall mean any physical connection or arrangement of piping or fixtures between two (2) otherwise separate piping systems one of which contains potable water and the other nonpotable water or industrial fluids of questionable safety, through which, or because of which, backflow or back-siphonage may occur into the potable water system. A water service connection between a public potable water distribution system and a customer's water distribution system which is cross-connected to a contaminated fixture, industrial fluid system or potentially contaminated supply or auxiliary water system, constitutes one type of cross-connection. Other types of cross-connections include but are not limited to connectors such as swing connections, removable sections, four-way plug valves, spools, dummy sections of pipe, swivel or changeover devices, sliding multiport tubes and solid connections. Cross-connection control by containment shall mean the installation of an approved backflow prevention device at the water service connection to any customer's premises where it is physically and economically infeasible to find and permanently eliminate or control all actual or potential cross-connection within the customer's water system; or it shall mean the installation of an approved backflow prevention device on the service line leading to and supplying a portion of a customer's water system where there is an actual or potential cross-connection which cannot be effectively eliminated or controlled at the point to the cross-connection. Cross-connection controlled shall mean a connection between a potable water system and a nonpotable water system with an approved backflow prevention device properly installed that will continuously afford the protection commensurate with the degree of hazard. Customer's system shall mean those parts of the facilities beyond the termination of the distribution system which are utilized in conveying city domestic water from the utility system to points of use. Director of public works shall mean the city engineer of the City of West Covina or his designee. Distribution system shall mean the network of conduits used for the delivery of water from the source to the customer's system. Hazard, degree of shall mean the potential risk to public health and the adverse effect of the hazard upon the potable water system, including but not limited to the following: (1) Hazard, health. Any condition, device or practice in the water supply system and its operation which could create, or in the judgment of the director of public works may create a danger to the health and well being of the water customer. An example of a health hazard is a structural defect, including cross-connection, in a water system. (2) Hazard, plumbing. A plumbing-type cross-connection in a customer's potable water system that has not been properly protected by a vacuum breaker, air-gap separation or backflow prevention device. Unprotected plumbing-type cross-connections are considered to be a health hazard. (3) Hazard, pollutional. An actual or potential threat to the physical properties of the water system or to the potability of the public or the consumer's potable water system but which would constitute a nuisance or be aesthetically objectionable or could cause damage to the system or its appurtenances, but would not be dangerous to health. (4) Hazard, system. An actual or potential threat of severe damage to the physical properties of the public potable water system or the consumer's potable water system or of a pollution or contamination which would have a protracted effect on the quality of the potable water in the system. Industrial fluids system shall mean any system containing a fluid or solution which may be chemically, biologically or otherwise contaminated or polluted in a form or concentration such as would constitute a health, system, pollutional or plumbing hazard if introduced into an approved water supply. This may include, but is not limited to: Polluted or contaminated waters; all types of processed waters and "used waters" originating from the public potable water system which may have deteriorated in sanitary quality; chemicals in fluid form; plating acids and alkalies, circulated cooling waters connected to an open cooling tower and/or cooling towers that are chemically or biologically treated or stabilized with toxic substances; contaminated natural waters such as from wells, springs, streams, rivers, bays, harbors, seas, irrigation canals or systems, etc.; oils, gases, glycerine, paraffins, caustic and acid solutions and other liquid and gaseous fluids used in industrial or other purposes or for fire-fighting purposes. Pollution shall mean the presence of any foreign substance (organic, inorganic, or biological) in water which tends to degrade its quality so as to constitute a hazard or impair the usefulness or quality of the water to a degree which does not create an actual hazard to the public health but which does adversely and unreasonably affect such waters for domestic use. Source shall mean all components of the facilities utilized in the production, treatment, storage and delivery of water to the distribution system. The utility system shall mean the source facilities and the distribution system and shall include all those facilities of the water system under the complete control of the city, up to the point where the customer's system begins. Water, potable shall mean any water which according to recognized standards is safe for human consumption. Water, nonpotable shall mean water which is not safe for human consumption or which is of questionable potability. Water-service connections shall mean the terminal end of a service connection from the public potable water system, i.e., where the water purveyor loses jurisdiction and sanitary control over the water at its point of delivery to the customer's system. If a meter is installed at the end of the service connection, then the service connection shall mean the downstream end of the meter. There should be no unprotected takeoffs from the service line ahead of any meter or backflow prevention device located at the point of delivery to the customer's system. "Service connection" shall also include a water service connection from a fire hydrant and all other temporary or emergency water service connections from the public potable water system. Water, used shall mean any water supplied by a water purveyor from a public potable water system to a customer's system after it has passed through the point of delivery and is no longer under sanitary control of the water purveyor. Water system as used herein shall mean that system made up of two (2) parts: The utility system and the customer system as those are defined herein.
(Ord. No. 1848, § 4, 6-25-90)
Ask a question about West Covina law
Corpus searches the West Covina sections it holds and shows the ones that match, with their citations. Free, no sign-in.