§ 23-249 — Cross-connection control program: Approved device
Municipal Code of the City of West Covina, California (Codified through Ordinance No. 2531, adopted July 15, 2025. (Supp. No. 94)) · West Covina Municipal Code § 23-249
Corpus is an independent public-information project, not the official City of West Covina website. Stable reference: corpuslaw.us/code/f5853b5a-a6dc-4a6a-a83c-9e6363690e0d
Sec. 23-249. - Cross-connection control program: Approved device.
(a) Any backflow prevention device required herein shall be of a model and size approved by the director of public works. The term "approved backflow prevention device" shall mean a device that has been manufactured in full conformance with the standards established by the American Water Works (AWWA) entitled: "AWWA C 506-78 Standards for Reduced Principal and Double Check Valve Backflow Prevention Devices," and have met completely the laboratory and field performance specifications of the foundation for cross-connection control and hydraulic research of the University of Southern California established by: "Specifications of backflow prevention assemblies—Section 10 of the most current issue of the Manual of Cross-Connection Control." Final approval shall be evidenced by a "Certificate of Approval" issued by an approved testing laboratory certifying full compliance with said AWWA standards and FCCC and HR specifications. The following testing laboratory has been qualified by the director of public works to test and certify backflow preventors: Foundation for Cross-Connection Control and Hydraulic Research University of Southern California University Park Los Angeles, CA 90007 Testing laboratories other than the laboratory listed above will be added to an approved list as they are qualified by the director of public works. Backflow preventors which may be subjected to back-pressure or back-siphonage that have been fully tested and have been granted a certificate of approval by a qualified laboratory above or on the approved list and are listed by the laboratory above or on the approved list and are listed on the laboratory's current list of "approved devices" may be used without further test or qualification. (b) Types of backflow prevention devices. (1) Air-gap separation (AG). An air-gap separation shall be located as close as practical to the user's connection and all piping between the user's connection and the receiving vessel shall be entirely visible unless otherwise approved in writing by the City of West Covina and the state department of health services. (2) Double-check valve assembly (DC). A double-check valve assembly shall be located as close as practical to the user's connection and shall be installed above grade, if possible, and in a manner where it is readily accessible for testing and maintenance. (3) Reduced pressure principle backflow prevention device (RP). A reduced pressure principle backflow prevention device shall be located as close as practical to the user's connection and shall be installed a minimum of twelve (12) inches above grade and not more than thirty-six (36) inches above grade measured from the bottom of the device and with a minimum of twelve (12) inches of side clearance. (c) Type of backflow protection required. (1) Sewage and hazardous substances: a. Premises where the public water system is used to supplement the reclaimed water supply—AG protection required. b. Premises where there are wastewater pumping and/or treatment plants and there is no interconnection with the potable water system. This does not include a single-family residence that has a sewage lift pump. An RP may be provided in lieu of an AG if approved by the health agency and water supplier—AG protection required. c. Premises where reclaimed water is used and there is no interconnection with the potable water system. An RP may be provided in lieu of an AG if approved by the health agency and water supplier—AG protection required. d. Premises where hazardous substances are handled in any manner in which the substance may enter the potable water system. This does not include a single-family residence that has a sewage lift pump. An RP may be provided in lieu of an AG if approved by the health agency and water supplier—AG protection required. e. Premises where there are irrigation systems into which fertilizer, herbicides, or pesticides are, or can be, injected—RP protection required. (2) Auxiliary water supplies: a. Premises where there is an unapproved auxiliary water supply which is interconnected with the public water system. An RP or DC may be provided in lieu of an AG if approved by the health agency and water supplier. b. Premises where there is an unapproved auxiliary water supply and there are no interconnections with the public water system. A DC may be provided in lieu of an RP if approved by the health agency and water supplier. (3) Fire protection system: Premises where the fire system is directly supplied from the public water system and there is an unapproved auxiliary water supply on or to the premises (not interconnected).
(Ord. No. 1848, § 4, 6-25-90)
Ask a question about West Covina law
Corpus searches the West Covina sections it holds and shows the ones that match, with their citations. Free, no sign-in.