Sec. 23-265. - General design and construction.

(a) General. All facilities and appurtenances of the water system shall be designed and constructed so that: (1) They can withstand, with ample safety factors, the physical stresses to which they are likely to be subjected, (2) They are free of structural and sanitary hazards, (3) They are of adequate size and capacity in order to meet minimum pressure requirements specified in paragraph (c) of this section. (b) Quantity of supply. (1) The quantity of water available from all of the water sources and distribution storage reservoirs shall be sufficient to supply adequately, dependably and safely the total requirements of all customers under maximum demand conditions. The serving water utility shall certify to the city council as to the adequacy of the available water supply. Such certification shall contain statements concerning the source of water, adequacy of transmission system to the area to be served, adequacy of storage capacity and any other statements that may be deemed necessary by the city council. Maximum customer requirement may be determined from adequately supported and documented system record or by Chart 1, hereby adopted by reference as if set out in this Code. The flow requirement indicated on Chart 1, hereby adopted by reference and on file in the planning department, is for average demands not including fire flow. This flow shall be appropriately supplemented, as required by the fire department of the city to take into consideration such factors as climate, community type, kinds of customers, and past experience. This flow shall be available continuously for at least two (2) hours, one-third (⅓) must be provided from the water source and the remainder may be provided from distribution storage. (2) A master meter, or other suitable measuring device, shall be provided for each source of water supply. (c) System pressure. (1) Normal operating pressure at the service connection shall not be less than twenty-five (25) pounds per square inch gauge, nor more than one hundred twenty-five (125) pounds per square inch gauge, except that during periods of hourly maximum demand at the time of peak seasonal loads the pressure may not be less than twenty (20) pounds per square inch gauge and that during periods of hourly minimum demand the pressure may be not more than one hundred fifty (150) pounds per square inch gauge. Variations in pressures under normal operation shall not exceed fifty (50) percent of the average operating pressure. The average operating pressure shall be determined by computing the arithmetical average of at least twenty-four (24) consecutive hourly pressure readings. (2) If the enforcement of the foregoing pressure regulations would result in undue hardship in supplying customers at widely varying elevations, the utility may make application to the city council for an exception from these provisions in the following manner: a. Written application shall be filed with the city council. b. The application shall include all information necessary to properly apprise the city council of the circumstances existing which require the exception. A copy of the application shall be forwarded to the city engineer for his report and recommendation. c. Within thirty (30) days after the filing of the application, the city council shall conduct a hearing thereon and may approve, amend and approve, or deny the application. The city council shall only approve an exception where full compliance with the foregoing pressure regulations is impractical or unreasonable based upon current engineering practice and the public health, safety and welfare would be served by granting such exception. No exception approved by the city council pursuant to this paragraph shall be effective for any purpose until the exception has been incorporated in a covenant running with the land to which the exception applies and the covenant is approved by the city attorney as to form and recorded in the office of the county recorder. (3) New water systems, or new pressure zones in existing water systems supplying customers at substantially constant elevation shall be designed to maintain an operating pressure at the service connection of not less than thirty-five (35) pounds per square inch gauge nor greater than one hundred twenty-five (125) pounds per square inch gauge. (4) Where the pressure in the mainline exceeds eighty (80) pounds per square inch gauge an approved type pressure regulator preceded by an adequate strainer shall be installed at each house and the pressure reduced to a maximum of eighty (80) pounds per square inch gauge.

(Code 1960, § 7622; Ord. No. 1371, § 1, 2-27-78)

Ask a question about West Covina law

Corpus searches the West Covina sections it holds and shows the ones that match, with their citations. Free, no sign-in.