Sec. 23-267. - Distribution system requirements.

(a) Length of run. (1) The maximum length of run of each size of pipe shall be determined by a pressure and flow analysis to be submitted to the city engineer, and shall be designed by a properly qualified and licensed engineer or similarly qualified individual to meet the requirements of section 23-265 of this division. The minimum size pipe allowed shall be eight (8) inches except on cul-de-sac streets where no fire hydrant is to be served, in such case the minimum size allowed shall be six (6) inches. (2) All dead end runs shall be provided with a means of flushing to prevent deterioration of water quality. (b) Design. Pipelines having a nominal inside diameter greater than twelve (12) inches shall be designed by and installed under the general supervision of a properly qualified licensed engineer or similarly qualified individual. Pipelines having a diameter of twelve (12) inches or less shall meet the applicable standards shown in Table I. Table I Pipe Standards American Water Works Association | American Soc. for Testing Material | Federal Specs. Asbestos-Cement | C400-73 | C296-72T | SS-P-351b Cast Iron | C106-75 | WW-P-421b C108-75 Ductile Iron | C151-76 Steel | C201-66 | SS-P-385a C202-64 Copper | C800-66 | B88-58 | WW-T-799b Concrete | C300-74 | SS-P-381a C301-72 C302-74 Plastic ABS | D2282-65 | CS270-65 PE | D2239-65 | CS255-63 PVC | D2241-65 | PS 22-70 PB | D2662-67 (c) Asbestos-cement pipe. Asbestos-cement pipe shall be selected in accordance with AWWA Standard C401-77 "Standard Practice for the Selection of Asbestos-cement Water Pipe," and shall be installed in accordance with AWWA Standard C603-65. (d) Cast iron pipe. Cast iron pipe shall be selected in accordance with AWWA Standard C101-67 and shall be installed in accordance with AWWA Standard C600-77. Cast iron pipe shall be cement mortar lined. (e) Ductile iron pipe. Ductile iron pipe shall be selected in accordance with AWWA Standard C150-76 "American Standard for the Thickness Design of Ductile Iron Pipe," and shall be installed in accordance with AWWA Standard C600-77. Ductile iron pipe shall be cement mortar lined. (f) Plastic pipe. Plastic pipe and couplings shall be approved by the National Sanitation Foundation and listed in the National Sanitation Foundation Manual "Plastic Materials, Pipe, Fittings and Appurtenances for Potable Water Supplies." Pipe shall be installed according to manufacturer's recommendation and care shall be observed not to damage pipe with backfill material. The pressure rating of all plastic piping components for water service at seventy-three and four-tenths (73.4) degrees Fahrenheit shall not be less than the sum of the maximum static pressure and a special allowance for surge pressure. The static design pressure shall be the actual static pressure, and in no case shall it be less than one hundred (100) pounds per square inch gauge. The special allowance for surge pressure shall be at least equal to the maximum anticipated surge pressure, but the allowance shall not be less than one hundred twenty (120) pounds per square inch gauge for pipe sizes four (4) inches through ten (10) inches and not less than one hundred ten (110) pounds per square inch gauge for twelve (12) inch pipe. The minimum wall thickness requirement for pipe shall be calculated on the basis of a system design pressure which complies with the above provisions. The wall thickness of fittings shall be adequate to withstand internal pressures equal to or greater than that of the pipe component of the joint. (g) Steel pipe. (1) Steel pipe shall be selected and installed in accordance with AWWA Manual M-11 (1964) "Steel Pipe-Designed and Installation." Design shall comply with sections 6.1 and 6.2 of Manual M-11, except that minimum allowable steel thickness shall be seventy-five thousandths (0.075) inches (fourteen (14) gauge). The minimum design pressure shall be at least the maximum anticipated system pressure, but in no case shall be less than one hundred sixty (160) pounds per square inch gauge. (2) All steel pipe shall be adequately protected from internal and external corrosion. Table 2 lists various protective coatings and linings. The selection of the appropriate coating or lining system shall be made by a properly qualified licensed engineer or based on satisfactory experience with a particular coating in the same or similar environment as that being considered. Cathodic protection installations shall be designed and installed under the direction of a properly qualified and licensed engineer or similarly qualified individual. Table II Steel Pipe Coatings and Linings Coatings | Specification Cement-mortar coated | AWWA C205-71 or Federal Spec. SS-P-385a Coal tar coated and wrapped | AWWA C203-73 Asphalt mastic | Asphalt Instit. M-2 CS-96 Extruded plastic coating | Federal Spec. L-C-00530 Linings Cement mortar lining | AWWA C205-71 or Federal Spec. SS-P-385a Coal tar lining | AWWA C203-73 (h) Service connection. Service pipe and fittings shall be designed for cold water working pressure of not less than one hundred fifty (150) pounds per square inch gauge. Copper tubing shall be commercial designation type K or L. Plastic tubing shall bear the approval and marking of the National Sanitation Foundation. (i) Valves. (1) Gate valves shall conform to the American Water Works Association Standard Specification C500-71 for double disc type. (2) Butterfly valves shall meet or exceed the American Water Works Association Standard Specification C504-74 for rubber seated valves. (j) Pits. Chambers or pits containing vacuum or air-relief valves shall be protected against flooding. Drains shall not be directly connected by pipe or other closed conduit to sewers or storm drains. (k) Joints. Pipe joints and appurtenances of all types shall safely withstand the same working pressures for which the pipe is designed. Where backup gaskets are required, rubber or asbestos shall be used. (l) Mains installation. (1) Water mains shall be installed below the frost line or be otherwise protected to prevent freezing and shall not have less than thirty-six (36) inches of cover over the top of the pipe in public streets or alleys except where it is necessary to avoid underground obstructions or rocky or hardpan conditions where such depth is not feasible. (2) Water pipes shall be laid at least ten (10) feet horizontally from and at a higher level than sanitary sewers. (3) All pipe or conduits, before being placed in service, shall be disinfected according to the American Water Works Association Standard Specification C601-68 for disinfecting water mains. Water samples shall be collected from new or repaired pipe for bacteriological examination following disinfection. (m) Fire hydrants. (1) Fire hydrants shall conform to AWWA Standard Specification C503-75 for wetbarrel fire hydrants and be Jones J-3700 type or approved equal. (2) Location of fire hydrants shall be as specified by the city fire department.

(Code 1960, § 7624; Ord. No. 1371, § 1, 2-27-78)

Ask a question about West Covina law

Corpus searches the West Covina sections it holds and shows the ones that match, with their citations. Free, no sign-in.