§ 15.10.030: Amendments to building planning.
Table R301.2 climatic and geographic design criteria is revised to read: TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground snow loado | WIND DESIGN | Seismic design categoryf | SUBJECT TO DAMAGE FROM | Ice barrier under-layment requiredh | Flood hazardsg | Air freezing indexi | Mean annual tempj Speedd(mph) | Topo. effectsk | Special wind regionl | Windborne debris zonem | Weatheringa | Frost line depthb | Termitec Zero | 95 | No | No | No | D2 or E | Negligible | 12-24" | Very Heavy | No | Yes/No | 0 | 60 MANUAL J DESIGN CRITERIAn Elevation | Altitude correction factore | Coincident wet bulb | Indoor winter design dry-bulb temperature | Indoor winter design dry-bulb temperature | Outdoor winter design dry-bulb temperature | Heating temperature difference 305 | | 70 | 75 | — | 34 Latitude | Daily range | Indoor summer design relative humidity | Indoor summer design relative humidity | Indoor summer design dry-bulb temperature | Outdoor summer design dry-bulb temperature | Cooling temperature difference 34 | 27 | — | — | | 89 For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. | Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for wreathing shall govern. The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(1). The grade of masonry units shall be determined from ASTM C34, ASTM C55, ASTM C62, ASTM C73, ASTM C90, ASTM C129, ASTM C145, ASTM C216 or ASTM C652. b. | Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. | The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. | The jurisdiction shall fill in this part of the table with the wind speed from the ultimate design wind speed map [Figure R301.2(2)]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. | The jurisdiction shall fill in this section of the table to establish the design criteria using Table 10A from ACCA Manual J or established criteria determined by the jurisdiction. f. | The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. | See City's FIRM maps for Flood Hazard Locations. h. | In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO." i. | The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." j. | The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." k. | In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. l. | In accordance with Figure R301.2(2), where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table. m. | In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table. n. | The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. o. | The jurisdiction shall fill in this section of the allowable stress design table using the Ground Snow Loads in Figure R301.2(3). Section R308 Site Address is hereby revised to read as follows: R308.1 Address Identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches in height with a stroke width of not less than 0.5 inch. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Section R309.3.6.2.2 Calculation procedure is hereby revised to read as follows: Section R309.3.6.2.2 Calculation procedure. Determination of the required size for water distribution piping shall be in accordance with the following procedure and California Fire Code Section 903.3.5.3. (The remainder of the section is unchanged)
( Ord. 2629 , 11/12/2025 )
Ask a question about Westminster law
Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.