§ 15.10.080 — Amendments to referenced standards

Code of Ordinances, City of Westminster, California (eCode360 WE5033 publication; scraped 2026-11-22) · Westminster Code of Ordinances § 15.10.080

Corpus is an independent public-information project, not the official City of Westminster website. Stable reference: corpuslaw.us/code/099c28a1-ae01-4724-89d3-f97a766f51f6

§ 15.10.080: Amendments to referenced standards.

Chapter 44 Referenced Standards is adopted in its entirety with the following amendments: NFPA 13, 2025 Edition, Standard for the Installation of Sprinkler Systems is hereby amended as follows: Section 16.12.3.3 is hereby revised as follows: 16.12.3.3 Fire department connections (FDC) shall be of an approved type. The location shall be approved and be no more than 150 feet from a public hydrant. The FDC may be located within 150 feet of a private fire hydrant when approved by the fire code official. The size of piping and the number of 2 1/2" inlets shall be approved by the fire code official. If acceptable to the water authority, it may be installed on the backflow assembly. Fire department inlet connections shall be painted OSHA safety red or as approved. When the fire sprinkler density design requires more than 500 gpm (including inside hose stream demand), or a standpipe system is included, four 2 1/2" inlets shall be provided. Section 9.4.3.1 is hereby revised as follows: 9.4.3.1 When fire sprinkler systems are installed in shell buildings of undetermined use (Spec Buildings) other than warehouses (S occupancies), fire sprinklers of the quick-response type shall be used. Use is considered undetermined if a specific tenant/occupant is not identified at the time the fire sprinkler plan is submitted. Sprinklers in light hazard occupancies shall be one of the following: (2) | Quick-response type as defined in 3.6.4.8 (3) | Residential sprinklers in accordance with the requirements of 8.4.5 (4) | Quick response CMSA sprinklers (5) | ESFR sprinklers (6) | Standard-response sprinklers used for modifications or additions to existing light hazard systems equipped with standard-response sprinklers (7) | Standard-response sprinklers used where individual standard-response sprinklers are replaced in existing light hazard systems Section 9.2.1.7 is hereby revised as follows: 9.2.1.7 Concealed spaces filled with noncombustible insulation shall not require sprinkler protection when approved by fire code official. NFPA 13D 2025 Edition, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes is hereby amended as follows: Section 7.1.2 is hereby revised as follows: 7.1.2 The sprinkler system piping shall not have separate control valves installed unless supervised by a central station, proprietary, or remote station alarm service.

( Ord. 2629 , 11/12/2025 )

Ask a question about Westminster law

Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.