§ 15.10.060 — Amendments to roof assemblies

Code of Ordinances, City of Westminster, California (eCode360 WE5033 publication; scraped 2026-11-22) · Westminster Code of Ordinances § 15.10.060

Corpus is an independent public-information project, not the official City of Westminster website. Stable reference: corpuslaw.us/code/25c5f30f-599a-4196-a9ed-20451897c086

§ 15.10.060: Amendments to roof assemblies.

Section R902.1 is amended by revising it to allow only class A or B roofs as follows: R902.1 Roofing assemblies. Roof decks shall be covered with materials as set forth in Sections R904 or with roof coverings as set forth in section R905. A minimum Class A or B roofing shall be installed in areas designated by this section or where the edge of the roof deck is less than 3 feet (914 mm) from a lot line. Where classes A or B roof assemblies are required, they shall be tested in accordance with ASTM E108 or UL 790. Where required, the roof assembly shall be listed and identified as to class by an approved testing agency. Exceptions: 1. | Class A roof assemblies include those with coverings of brick, masonry and exposed concrete roof deck. 2. | Class A roof assemblies also include ferrous or copper shingles or sheets, metal sheets and shingles, clay or concrete roof tile, or slate installed on non-combustible roof decks or ferrous, copper or metal sheets installed without a roof deck on noncombustible framing. Section R902.1.2 is amended by revising it to require a minimum Class B roof as follows: R902.1.2 Roof coverings in all other areas other than Fire Hazard Severity Zones or a Wildland-Urban Interface (WUI) area. The entire roof covering of every existing structure where more than 50 percent of the total roof area is replaced within any one-year period, the entire roof covering of every new structure, and any roof covering applied in the alteration, repair or replacement of the roof of every existing structure, shall be a fire-retardant roof covering that is at least Class B fire classification. Section R902.2, first paragraph is amended by revising it to allow only Class A or B treated wood roofs as follows: R902.2 Fire-retardant-treated shingles and shakes. Fire-retardant-treated wood shakes and shingles are wood shakes and shingles complying with UBC Standard 15-3 or 15-4 which are impregnated by the full-cell vacuum-pressure process with fire-retardant chemicals, and which have been qualified by UBC Standard 15-2 or ASTM E108 or UL790 for use on Class A or B roofs.

( Ord. 2629 , 11/12/2025 )

Ask a question about Westminster law

Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.