§ 42-105 — IFC - Section 3307.1.4.2 Surface
Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Code of Ordinances § 42-105
Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/d150108f-f600-4d9c-90da-b554739c7746
Sec. 42-105. - IFC - Section 3307.1.4.2 Surface.
Section 3307.1.4.2. Surface, is hereby added to read as follows: "3307.1.4.2. Surface. Temporary fire apparatus access roads shall have an all-weather surface consisting of the first lift of asphalt, concrete, alternative design as approved by a geotechnical engineer. The surface shall be capable of supporting an 90,000-pound imposed load, all weather maintainable and free from obstructions. Documentation from a licensed civil engineer attesting that the surface will support the required imposed load shall be provided."
(Ord. No. 4922, § 3, 3-24-2026)