§ 42-98 — IFC - Section 1103.7.6. Group R-2

Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Code of Ordinances § 42-98

Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/bf132196-ab57-4a7c-9d3f-365d1e720dae

Sec. 42-98. - IFC - Section 1103.7.6. Group R-2.

Section 1103.7.6. Group R-2, is amended in in its entirety to read as follows: "1103.7.6 Group R-2. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in existing Group R-2 occupancies more than three stories in height or with more than 24 dwelling or sleeping units. Exceptions: 1. Where each living unit is separated from other contiguous living units by fire barriers having a fire-resistance rating of not less than ¾ hour, and where each living unit has either its own independent exit or its own independent stairway or ramp discharging at grade. 2. A separate fire alarm system is not required in buildings that are equipped throughout with an approved supervised automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2 and having a local alarm to notify all occupants. 3. A fire alarm system is not required in buildings that do not have interior corridors serving dwelling units and are protected by an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, provided that dwelling units either have a means of egress door opening directly to an exterior exit access that leads directly to the exits or are served by open ended corridors designed in accordance with Section 1027.6, Exception 3. 4. A fire alarm system is not required in buildings that do not exceed three stories in height and comply with all the following: 4.1. Each dwelling unit is separated from the corridor and from other contiguous dwelling units by fire barriers having a fire-resistance rating of not less than ¾ hour. 4.2. Each dwelling unit is provided with smoke alarms complying with the requirements of Section 907.2.11. 4.3. Doors from each dwelling unit to the exit or exit access shall meet the requirements of the International Building Code Section 716.2 for fire resistance, closing, and latching."

(Ord. No. 4922, § 3, 3-24-2026)

Ask a question about Arvada law

Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.