§ 5-1-2-3 — General building design standards
Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Land Development Code, art. 5-1, § 5-1-2-3
Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/95a05b85-fe06-4a21-b628-96f086f6fd90
5-1-2-3. - General building design standards.
A. Building Orientation. Primary buildings shall emphasize the location and importance of the entryways. 1. The main entrance or a courtyard leading to the main entrance of each principal building shall be located on the front facade. 2. On corner lots, the main entrance shall face one of the streets or be oriented to the corner. B. Massing. Primary buildings shall be designed to avoid a monolithic appearance when viewed from the street. C. Facade Materials and Design. 1. General Requirements. a. All building exterior finish materials shall be durable and consistent with the architectural style for that building. b. Where lap siding is used, it shall have a maximum nine-inch exposed board face. c. Siding material shall be continued down to within nine inches of finished grade on any elevation, except that siding shall be allowed to step to follow grade: i. Between six to 24 inches; or ii. Within 24 inches maximum from finished grade. d. Vinyl siding shall be a VSI (Vinyl Siding Institute) certified product. 2. Prohibited Materials. The following materials are prohibited: a. Highly reflective opaque materials; b. Natural cinder block, unfinished or smooth concrete block/masonry units or concrete wall; c. Metal panels with a corrugated appearance or with exposed fasteners; and d. Unlisted materials that are unsuitable for exterior building applications as determined by the Director. 3. Other Materials. The Director may permit materials that are not listed in this Section as either allowed or limited, provided that the Director finds that they have comparable aesthetic qualities, durability, and maintenance characteristics. The Director may prohibit materials that are not listed in this Section if the Director finds that they do not have aesthetic qualities, durability, and maintenance characteristics that are comparable to the materials that are allowed or limited under this Section. 4. Side and Rear Facade Design. Where a side or rear facade of a residential building abuts streets, parks, or open spaces, the facade shall be designed to provide human scale by the use of all of the following: a. At least one change in the vertical or horizontal wall plane within 20 feet above grade; b. At least one change in the color or material of the wall; c. Provision of windows, a porch, or a balcony; and d. Detailing the wall with reveals, belt courses, cornices, projections, or other devices. 5. Rear Facade Design for Double-Frontage Lots. a. Double-frontage lots shall be required to meet the standards in Section 2-1-10-5, Double-Frontage Lots, for building setbacks or stepped setbacks for taller buildings. b. Structures of two stories or more shall incorporate at least one of the following rear elevation treatments: i. The building façade on the rear elevation shall have brick, stone, or stucco cladding in a minimum amount equivalent to 50 percent of the façade, (excluding windows, doors, trim and vents) from the average grade to the highest eave or 9′-6″ above the average grade, whichever is lowest; or ii. At least 50 percent of the area of the building facade shall have a minimum four-foot horizontal difference (plan view) in the rear wall plane at the height of one of the floors. 6. 360-Degree Architecture. All buildings shall incorporate the following design standards to create architectural interest. a. Materials. i. Where brick, stone, or stucco cladding is used, they must be applied to the building facade in a manner which begins and ends at edges related to the structure of the building (such as a window sill level, floor plane lines, or interior corners of projection or similar elements). All brick, stone or stucco cladding shall wrap around all outside building corners a minimum of two feet, and must wrap all sides of a column on which it is used. An architectural treatment shall be used to transition from brick, stone, or stucco to other materials. b. Windows and Doors. i. Windows are encouraged on all elevations, except as provided in Division 2-1-8-5, Zero Lot Line, and unless restricted by the Building Code. On facades facing streets, parks, or open space, a minimum of 20 percent of the façade shall be windows. A greater percentage of windows may be required by other sections of this Code. ii. Window and door openings shall be articulated on all elevations of the building through the use of: a. Shutters, awnings or canopies; b. Decorative lintels and/or sills (such as projecting, recessed, those constructed of materials other than the principal building material or ornamentation); c. Overhangs; or d. Surrounds and trims. 7. Façade and Roof Color. Colors used on building exteriors should integrate a building's various design elements or features. a. Walls should be subdued in color and not reflective. Bright colors should be used sparingly and limited to accenting a building, and should not be used to act as signs or create "sign buildings". Monotonous color palettes are strongly discouraged. b. All building projections, including, but not limited to, gutters, downspouts, chimneys, flues and vents, shall match in color the permanent color of the surface from which they project or match the building's trim color. 8. Rooflines. a. Building rooflines visible from a public street, park, or open space shall incorporate features to create a varied and visually distinctive roof form through features, such as prominent cornice or fascia, stepped roofs, emphasized dormers, chimneys, gables, or an articulated roofline. b. Roof slopes, excluding covered porches and patios, shall have a minimum pitch of 2:12 unless screened with a parapet wall. Subordinate roofs can be of a lesser pitch. A building of a style that is traditionally associated with flatter roofs, such as Prairie or Modern style, may be allowed as determined by the Director. c. The maximum length of a continuous roof ridgeline is 35 feet. Roofs with dormers and other architectural details are exempt from this requirement. d. Pitched roofs shall have a minimum eave overhang of at least one-foot. 9. Canopies and Port-Cochères. Canopies and port-cochères that cover vehicular use areas, service areas, or outdoor storage areas shall meet the following standards: a. The same architectural treatments utilized on the principal building in terms of cladding materials, roof pitch, roofing materials, and color scheme shall be used on canopies and port-cochères. b. A maximum of 25 percent of each canopy fascia area visible from a public street may be internally illuminated, and no portion of any fascia may be externally illuminated. Each side of a canopy shall be considered a separate fascia area. 10. Rooftop, Wall Mounted and Ground Mounted Mechanical Equipment, Flues and Exterior Building Elements. a. Screening. i. Rooftop mechanical equipment and appurtenances should all be screened from a public street through the use of parapets or enclosures that are equal to, or greater than, the height of the equipment to be screened. The parapet or enclosure shall use one of the predominate materials or colors used on the primary façade of the building. ii. All air conditioning compressors shall be completely screened. Screening enclosures shall use at least one of the predominant materials used in the facades of the primary structure where feasible, and one of the predominant colors used in the primary structure. iii. All rooftop and wall vents and flues on a pitched roof or extending above the top of the nearest parapet shall be painted with one of the predominant colors used in the primary structure. iv. Wall-mounted utility equipment and meters shall be screened from view from a public street and shall be painted a color to blend with the building façade. v. Screening for ground mounted mechanical equipment, such as generators, within a front yard or common area shall be approved at the discretion of the Director. vi. The Director may reduce or waive these screening requirements for building elevations that face substantial changes in grade that make screening impracticable if relocation of the mechanical equipment to a less conspicuous location is also impracticable. b. Noise attenuation. Equipment that generates noise perceptible at the adjacent street or property line shall be baffled or otherwise attenuated to direct unavoidable noise upward.
(Ord. No. 4793, § 4, 3-21-2022; Ord. No. 4905, §§ 56, 57, 8-19-2025)
Ask a question about Arvada law
Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.
