For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-1-2-8 — Industrial, self-storage, or distribution

Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Land Development Code, art. 5-1, § 5-1-2-8

Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/18d3ab4f-0d14-427e-ac8b-70ddf987d2d2

5-1-2-8. - Industrial, self-storage, or distribution.

A. Generally. In addition to the standards in Division 5-1-2, Building and Structure Design Standards, the following standards shall apply. B. Building Design. 1. No façade of an industrial structure may exceed 40 feet in height without a change in cladding material or surface plane. 2. Each primary entrance for employees or visitors that faces a public right-of-way shall be emphasized through the use of differing colors or materials, arches, arcades, or other architectural treatments. 3. Except in the IG zoning district, all front façades of primary structures, and all side wall façades within 40 feet of the front façade, shall be of masonry (brick, stone, and/or stucco). 4. All primary structures with flat roofs shall include a parapet or fascia around all sides of the building. 5. Except in the IG zoning district, walls other than the front façade of a principal building may be clad with architectural metals, but when such metals are used on side wall façades they shall not extend closer than 40 feet to the front façade of the building. 6. Façades of the primary structure shall incorporate architectural relief through the use of at least two of the following tools: a. Reveals or visible joint patterns; b. Projected sills; c. Belt courses, reporting brick header and stretcher courses; or d. Differing colors and textures. 7. Wherever consistent with the standards above, the design of primary structures shall reflect the activities conducted within the building, or the mechanical or structural systems of the building, through the use of special roof shapes (such as skylights) or special corner treatments. C. Additional Standards for IL and IG Zoning Districts. Self-storage located in IL and IG zoning districts shall be contained within an enclosed building or buildings. All buildings shall be architecturally compatible with the surrounding zoning. Architectural compatibility shall be measured as follows: 1. Buildings constructed abutting a residential zone district shall employ sloped roofs and shall display wall relief features and colors commonly found in residential construction. 2. Buildings abutting CG zone district may employ less variation. D. Additional Standards for CG and MX-S Zoning Districts. Self-storage buildings identified as a conditional use in the CG and M-X zoning districts shall also meet the following standards: 1. Vertical Dimensions. All self-storage buildings shall be multi-story. Self-storage buildings shall be designed with a Primary Corner Element. The Primary Corner Element must consist of an area that is between 15 and 40 percent of the building print which appears to have a variation in height as follows: a. The Primary Corner Element must contain at least one offset in building or parapet height of at least 2.5 feet; and b. The Primary Corner Element shall be designed so that it is a prominent feature of the front and, if present, a street-side elevation. If there is more than one street frontage, then this requirement applies only to the primary street frontage. 2. Horizontal Dimensions. a. Vertical planes of building elevations shall be horizontally offset at least one foot at intervals not to exceed 50 feet. Such offsets shall have a horizontal dimension of at least five feet. Such offsets are not required on the ground floor. The roofline shall be differentiated for each interval (e.g., variations in parapet design, vertical articulation, changes in materials, changes in forms, etc.). b. Vertical planes of the Primary Corner Element shall be offset outward from other vertical planes of the building by at least two feet, regardless of the horizontal distance to the next vertical plane offset. 3. Transparency. a. In the CG and MX-S zoning districts, street facing walls of the Primary Corner Element shall include windows or glass doors of not less than 25 percent, and all other building elevations shall include windows (or translucent cladding materials that closely resemble windows) of not less than 15 percent. 4. Building Access. a. The principal public entrance to the building shall be incorporated into the Primary Corner Element as a prominent feature. All other doors (overhead doors and standard doors) that are visible from outside the building, directly or through the windows, shall be de-emphasized through the use of colors that closely resemble the colors of the surrounding walls or façade. Bright, primary, and fluorescent colors are not allowed. b. No overhead doors shall be located within: i. Fifty feet of a residential property line; or ii. Ten feet of a major building corner of a building elevation. c. In the CG and MX-S zoning districts: i. Not more than one overhead door may be located on the front building elevation. ii. All other exterior overhead doors shall be screened from view from abutting streets and residential zone districts with a bufferyard type in Section 4-6-5-3 or equivalent screening approved by the Director. d. Elevated truck loading docks shall not be located on the primary street frontage or on elevations that abut a residential property line. E. Cladding Materials. Buildings shall be clad with a mix of durable, low maintenance materials that convey an appearance of quality. 1. Allowed cladding materials include: a. High grade metal composite panels with a durable, factory-applied finish, provided that colors or textures are varied to prevent a monolithic appearance; b. Brick, brick veneer, stone, simulated stone, or stucco; c. Cement fiberboard; or d. Concrete masonry units ("CMUs") with integrated color, provided that the outer surface of the CMUs is either split face or ground face. 2. Prohibited cladding materials include: a. Un-backed, non-composite sheet metal products (e.g., standing-seam metal or flat panels that may oil-can or easily dent); b. Smooth face CMUs that are painted or unfinished; c. Board and batten siding; d. Plastic or vinyl siding; or e. Unfinished wood. 3. Other cladding materials that are not listed above may be approved by the Director based on a determination of their durability, quality, and appearance compared to the allowed cladding materials as described above.

Ask a question about Arvada law

Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.