5-1-2-6. - Nonresidential and mixed-use design standards.
A. Generally. This Section shall apply to any new nonresidential development, horizontal and vertical mixed-use development, redevelopment, or building expansion in all zoning districts. In addition to Section 5-1-2-5, Building Design Standards Applicable to Townhomes and Multifamily, the following standards shall apply to new development or redevelopment of multifamily and townhome units in the MX zoning districts. In the OT Zoning District, these standards may be modified through the design review process based on the standards in the Olde Town Building Form Standards and Design Guidelines for Olde Town. B. Building Orientation and Configuration. 1. Structures shall be arranged so that the primary facade, or each facade with a main pedestrian entry, orients onto a public or private street, a public park, open space or common green, plaza, courtyard, private street-like drive, or a pedestrian passage, in the following order of priority: a. A public or private street; b. A pubic park, open space or common green; c. A plaza or courtyard; or d. A pedestrian walkway. C. Single-Story Commercial and Mixed-Use Developments. 1. Commercial and mixed-use developments shall break up supporting commercial buildings into a cluster of individual pad and liner buildings at intersections and street edges. 2. Pad and liner buildings located within the frontage zone shall be designed to be "double-fronted", where at least one entrance shall face the street or public space, following the order of priority in B.1 above. Secondary entries can be oriented to the parking lot. 3. Large commercial or large format buildings with a minimum of 50,000 square feet of gross area, such as a grocery store or big box retail building, may be placed internal to the site. D. Multi-Building Developments. 1. Multi-building developments that have three or more buildings shall be organized to create pedestrian-friendly spaces and streetscapes. This should be accomplished by placing buildings to: a. Frame and emphasize the corners of street intersections, development entry, or a primary pedestrian street within the development; b. Frame and enclose parking areas on at least two sides; c. Frame and emphasize a plaza, pocket park, square, or other outdoor gathering spaces for pedestrians; and/or d. Frame and emphasize other site improvements as approved by the Director. 2. Developments composed of multiple buildings totaling 100,000 square feet or more of gross floor area shall be configured to break up the site into a series of smaller blocks. E. Building Design. The following building design standards are intended to provide architectural interest. 1. Design of Facades. a. The first floor façade of all buildings, including structured parking facilities, shall be designed to encourage and complement pedestrian-scale interest and activity through the use of elements such as windows, awnings, and other similar features. b. Architectural features and treatments shall not be limited to a single façade. All visible sides of a building, whether viewed from public or private property, shall display a similar level of quality and architectural interest, with elements such as windows, awnings, a variety of exterior materials, reveals, and other similar features. 2. Horizontal and Vertical Articulation. a. General Standards. All buildings shall be designed to include horizontal and vertical articulation by incorporating the following elements: i. Single story commercial buildings shall use at least three of the horizontal articulation methods listed below at an interval of 50 feet or less on each façade. ii. Single story industrial buildings shall use at least two of the horizontal articulation methods listed below at an interval of 100 feet or less on each. iii. All multi-story commercial, mixed-use, multifamily, and industrial buildings in the IL zoning district, shall use at least two of the articulation methods listed below at an interval of 50 feet or less on each street-facing building façade. b. Articulation Methods. i. Visual breaks in the façade by incorporating a horizontal wall plane offset or projection of at least three feet extending for at least 20 percent of the average width of the primary façade. ii. A change in materials, colors, textures, or pattern. iii. A change in window sizes, styles, or placement across the façade. iv. A change in roof or parapet height of a least three feet, or a change in roof form. v. Incorporation of a wall notch in combination with at least one option from (i.—iv.) above. Wall notches shall be a minimum of three feet deep and eight feet wide and shall total at least 20 percent of the façade length. vi. Use of masonry such as brick or stone, or other durable material to delineate the ground floor. vii. Use of an arcade, gallery or colonnade to accentuate the ground floor. viii. Use of enhanced architectural detailing or fenestration. ix. Use of cornices or projecting roof lines. x. For multi-story buildings, the horizontal interval may exceed 50 feet if building material changes and/or articulation occur above the first floor. [image omitted; see the official code] F. Building Transparency. The entire ground floor of all buildings located within a required building frontage zone that faces a public or private street shall provide transparency to increase pedestrian interest by incorporating window and door openings so that the uses are visible from and to the street. The following shall apply: 1. At least 40 percent of the façade between two feet and 10 feet above grade, must be transparent. 2. Up to 20 percent of the building transparency requirement may be satisfied with permanent art displays. G. Roofs Materials and Roof Form. 1. Roof Materials. Visible roofs may be constructed of conventional asphalt (3-tab) roofs, architectural metal, or other acceptable material, but roofs constructed of clay or concrete tiles, slate, Masonite, or heavy duty/hail resistant dimensional composition are preferred. All composition shingle roofing shall be constructed using high profile, textured shingles. 2. Roof Form. a. Where sloped roofs are used, at least one of the following elements shall be incorporated into the design for each 100 linear feet of roof to avoid long, flat roof surfaces: i. Projecting gables, ii. Dormers, iii. Hips, iv. Vertical elevation change in roof height of at least two feet, or v. Other similar techniques as approved by the Director. b. Where flat roofs are used, the design or height of the parapet shall include at least one change in setback or height of at least two feet along each 100 linear feet of façade. c. On all structures exceeding three stories in height, all pitched roofs shall be internally drained and external scuppers and wall drains shall be prohibited. d. All sloped roofs shall have overhanging eaves of at least one foot in depth, and roofs with a pitch of less than 2:12 shall be screened by a parapet wall.
(Ord. No. 4793, § 4, 3-21-2022; Ord. No. 4905, § 58, 8-19-2025)
Ask a question about Arvada law
Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.