For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-6-704 — Limits on the Connected Load for Exterior Lighting

Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 12-6-704

Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/c9e17c17-672f-44cb-97dd-ebbdd0ccc1ab

Sec. 12-6-704. - Limits on the Connected Load for Exterior Lighting.

A. Generally. The connected load for all exterior lighting shall be no greater than permitted through the exterior lighting power allowances and additional allowances, where applicable, as described in this Section. B. Exterior Lighting Power Allowances. The exterior lighting power allowances may be used anywhere on the site. • 0.15W per square foot of parking lots and drive aisle; • 1.0W per linear foot of walkways less than 10 feet in width; • 0.2W per square foot of walkways greater than 10 feet in width, plazas and special features; • 1.0W per square foot of stairways; • 30W per linear foot of the doorway at the main building entryway; • 20W per linear foot of the doorway at any other building entryway; • 1.25W per square foot of canopies and overhangs; • 0.5W per square foot of open outdoor sales areas (including vehicles) as defined in Section 12-3-807, Outdoor Display of Merchandise; and • 20W per linear foot of street frontage for vehicle sales. C. Additional Allowances. The lighting permitted by these additional allowances shall be restricted to the specific application and may not be used anywhere else on the site. Table 12-6-704 Additional Connected Load Allowances for Specific Applications Use | Maximum Outdoor Display Area Walls/Surfaces | The greater of 0.2W per square foot of illuminated walls or surfaces or 5.0W per linear foot of the length of illuminated walls or surfaces ATMs | 270W per individual location of an ATM and 90W for each additional ATM at the same location Inspections | 1.25W per square foot of uncovered area for inspections at guarded facilities Emergency Response | 0.5W per square foot of uncovered area for emergency vehicle access Drive-through Lanes | 400W per drive-through 24-hour Commercial Retail | 800W per public entryway to the building

Ask a question about Centennial law

Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.