§ 12-6-705 — Establishment of Lighting Zones and Requirements
Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 12-6-705
Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/a8128618-32dd-489c-8a59-2cc90a40fd25
Sec. 12-6-705. - Establishment of Lighting Zones and Requirements.
A. Generally. This Section establishes five Lighting Zones, LZ-0 through LZ-4 from darkest to brightest. Table 12-6-705A, Lighting Zone Assignment from Zoning, assigns a Lighting Zone to each zoning district pursuant to potential lighting requirements for each zoning district and in accord with the purpose of the exterior lighting standards. Lighting Zones LZ0 and LZ4 are available only as a conditional use subject the requirements of Section 12-14-601, Conditional Use and Temporary Conditional Use Procedures. Table 12-6-705A Lighting Zone Assignment from Zoning District Classification | Abbreviation | District Name | Lighting Zone Agriculture | AG | AGriculture | LZ1 Residential | RS | Suburban Residential | LZ1 Residential | RA, RU, NC, NI | Auto-Urban Residential, Urban Residential, Neighborhood Conservation, Neighborhood Infill | LZ2 Commercial and Mixed-Use | CG, AC, UC, EC-MU | General Commercial, Activity Center, Urban Center, Employment Center - Mixed Use | LZ3 Industry and Business | EC-N , EC-LI, BP, I | Employment Center - Neighborhood, Employment Center - Light Industrial, Business Park and Industrial | LZ2 Public, Institutional, and Open Space | ED | Education, Institutional, and Recreation | LZ3 Public, Institutional, and Open Space | OSR | Public Open Space and Recreation | LZ1 B. Illuminance, Luminance, and Uniformity Requirements. Table 12-6-705B, Illuminance and Uniformity Requirements, gives the maximum allowable illuminance and minimum uniformity requirements for each of the Lighting Zones. Maximum illuminance values shall be horizontal measurements at grade under initial conditions. All values are in photopic units. For Illuminance, luminance, and uniformity requirements on public and private streets, refer to the Roadway Design & Construction Standards Manual. Table 12-6-705B Illuminance and Uniformity Requirements Area | Classification | Maximum Illuminance (footcandles) | Maximum Value for Uniformity Ratio Walkways | LZ0, LZ1 | 1.0 | 10:1 avg:min LZ2 | 2.0 | 10:1 avg:min LZ3 | 4.0 | 4:1 avg:min LZ4 | 6.0 | 4:1 avg:min Parking - Non-residential | LZ0, LZ1 | 5.0 | 20:1 max:min LZ2 | 7.5 | 20:1 max:min LZ3 | 10.0 | 20:1 max:min LZ4 | 15.0 | 20:1 max:min Parking - Residential | LZ0, LZ1 | 5.0 | 20:1 max:min LZ2 | 6.0 | 20:1 max:min LZ3 | 7.0 | 20:1 max:min LZ4 | 7.5 | 20:1 max:min Outdoor Display of Merchandise (Sec. 12-3-807) | All Lighting Zones | 35.0 | 20:1 max:min C. Exceptions to Illuminance and Uniformity Requirements. All exterior lighting shall comply with the maximum illuminance and minimum uniformity requirements set in Table 12-6-705B, Illuminance and Uniformity Requirements, except: 1. For driveways between parking areas and roadways where the roadway is permitted a greater illuminance than the parking area, the maximum illuminance for the driveway shall be allowed to equal the roadway's maximum illuminance. Further, this driveway area shall be considered separate from the parking area for the purposes of calculating the uniformity ratio. D. Spill Light Limits. Lighting Zones designate how much spill light is permitted onto a property from an adjacent property. The relevant Lighting Zone is the one for the property receiving the light from an adjacent property. Spill light may be measured by either horizontal measurements at grade or by vertical measurements at the property line up to the height of the highest window on the property receiving the spill light. Where vertical measurements at the property line are impractical, measurements at windows may be substituted. E. Exceptions to Spill Light Limits. All exterior lighting shall comply with the spill light limits set in Table 12-6-705C, Spill Light-Maximum Limits, except: 1. Spill light onto public rights-of-way at entries to a property may be the greater of one third of the maximum allowed illuminance for the parking area on the property or one third of the maximum allowed illuminance for the roadway; and 2. When the maximum light spill at a boundary between two properties exceeds the limits specified in Table 12-6-705C, Spill Light-Maximum Limits, due to the contributions from existing lighting located on either the receiving property or another adjacent property not subject to the proposed development or redevelopment. Table 12-6-705C Spill Light - Maximum Limits Lighting Zone | Maximum Horizontal or Vertical Measured Illuminance at the Property Line, Excluding Public Rights-of-way (footcandles) LZ0 | 0.1 LZ1 | 0.2 LZ2 | 0.4 LZ3 | 0.8 LZ4 | 1.5
(Ord. 2024-O-13 §54; Ord. 2024-O-15 §§15, 16)
Ask a question about Centennial law
Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.