For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-6-706 — Lighting Equipment Restrictions

Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 12-6-706

Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/18ed0e65-dd39-42e8-a2f5-baf28ff2c7b5

Sec. 12-6-706. - Lighting Equipment Restrictions.

A. Generally. The lighting equipment restrictions established in this Section apply to all Lighting Zones. B. Lamp Spectrum Restrictions. Lamps shall have a Correlated Color Temperature (CCT) less than 4600K, except for lighting for outdoor sports facilities. C. Rated Lamp Lumen Restrictions. Lamps and luminaires shall comply with the restrictions concerning shielding in Table 12-6-706, Rated Lamp Lumen Restrictions. See Figure 12-6-706A, Shielded and Unshielded Luminaires. Table 12-6-706 Rated Lamp Lumen Restrictions Type of Fixture | Any Light Fixture Mounted Less than 4 Feet Above Grade | Wall or Ceiling Mount Light Fixture Above 4 Feet | Pole Mounted Light Fixture Above 4 Feet and Less than 15 Feet | Pole Mounted Light Fixture Above 15 Feet Unshielded | 480 1 | 480 1 | 480 1 | 480 1 Shielded | 1,800 | Wall: 1,800 | Ceiling: 3,600 | 10,000 | 20,000 Fully Shielded | 10,000 | 10,000 | 20,000 | 30,000 Full Cut-off | n/a | 30,000 | 30,000 | 60,000 1 Up to three lamps of this lumen rating per fixture are allowed. Figure 12-6-706A Shielded and Unshielded Luminaires Unshielded Luminaires (below) [image omitted; see the official code] Shielded Luminaires (below) [image omitted; see the official code] D. Distribution Restrictions. House side shields shall be required for all full cut-off light fixtures installed within a distance of 2.5 times the mounting height of the property line. The house side shields shall limit the light output from the fixture in the direction of the nearest property line. See Figure 12-6-706B, House Side Shields. No floodlights, including reflector lamps, shall be aimed off the property. Figure 12-6-706B House Side Shields Full cut-off light fixture without a house side shield; full-cut-off light fixture with an internal house side shield; and full-cut-off light fixture with an external house side shield (left to right). [image omitted; see the official code] E. Mounting Height Restriction. For parking areas, the maximum height of light poles shall be: 1. Eighteen feet when located up to 50 feet from the property line of areas zoned for residential uses, except when the residential uses are located within an AC or UC zoning district. 2. Twenty-five feet when located 50 to 100 feet from the property line of areas zoned for residential uses, except when the residential uses are located within an AC or UC zoning district. 3. Thirty-five feet when located more than 100 feet from the property line of areas zoned for residential uses. All other light fixtures shall not be mounted higher than 25 feet or the maximum building height on the site, whichever is greater. F. Mounting Method Restrictions. Luminaires using lamps with more than 20,000 rated lumens shall meet the following constraints: 1. Shall not use a spider or yoke mounting configuration; and 2. Shall be mounted on a dark color pole (less than 35 percent reflective). G. Mounting Placement Restrictions. Where light poles or bollards are used, they shall be placed: 1. Within landscape islands in parking areas or on the perimeter of the parking lot and at least three feet away from the face of the curb; 2. At least five feet from the point where a curb transitions into a driveway, curb cut, or alley way; and 3. At least 30 feet from the extended flow line of the nearest intersection. H. Architectural Accent Lighting Restrictions. External illumination may only be used to accent important building entries or specific architectural features. General floodlighting of building façades is not permitted. In addition: 1. External illumination of signs shall be subject to the requirements of Section 12-6-304, Illumination of Signs; and 2. All canopy lighting shall: a. Use recessed light fixtures; and b. Shall not use highly reflective material on the underside of the canopy. I. Restrictions on Hours of Operation. For all non-residential properties, any building, service, sales and loading area lighting, except lighting for security purposes, shall be turned off one hour after business operations have ceased for the day and shall remain turned off until one hour before business operations resume on the next day. In addition: 1. Floodlights shall not be used to light any portion of a building façade between the hours of 10:00 p.m. and 6:00 a.m., except: a. In the UC or AC zoning district, locations and configurations that meet the following criteria shall be exempt from the floodlight restrictions: i. Locations that are not visible from residential uses in other zoning districts; and ii. The lighting system does not shine light into windows of residential uses within the site.

Ask a question about Centennial law

Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.