§ 10-38 — Specific standards for floodproofing
Fort Collins Municipal Code (Supp. No. 156, Update 2: codified through Ordinance No. 122, 2026, enacted September 15, 2026) · Fort Collins Municipal Code § 10-38
Corpus is an independent public-information project, not the official City of Fort Collins website. Stable reference: corpuslaw.us/code/a15a202c-2042-46c9-bab3-5faa5401231d
Sec. 10-38. - Specific standards for floodproofing.
Any structure or portion of a structure eligible to substitute floodproofing in lieu of compliance with the applicable elevation requirement of Subsection 10-37(b) shall meet the following requirements, which shall be referred to as floodproofing requirements: (1) In order for a structure to be eligible to comply with this Article through these floodproofing requirements: a. The structure must be a nonresidential structure, a nonresidential use portion of a mixed-use structure, an accessory structure or an attached garage; and b. The flood depth surrounding the structure must not exceed three (3) feet. (2) The structure must be designed and constructed to be floodproofed so that: a. Below the regulatory flood protection elevation, the structure is watertight with walls substantially impermeable to the passage of water; b. All structural components are capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy from flooding; c. The structure complies with the FEMA flood-resistant materials and floodproofing requirements in effect as of the date of the floodplain use permit; and d. Adequate drainage paths to guide floodwaters around and away from the structure are provided consistent with the requirements of § 26-544. (3) The following must be submitted to the Utilities Executive Director and accepted as completed prior to issuance of a floodplain use permit and a building permit: a. A pre-construction floodproofing certificate, signed and certified by a registered professional engineer or architect, accurately documenting the proposed floodproofing elevation; b. Detailed plans for floodproofing measures that include: 1. Base flood elevation and elevation of floodproofing; 2. The benchmark used; 3. Design details and locations of the specific floodproofing measures; 4. The direction and distance that all doors swing, in order to show that floodproofing closure shields, if any, cannot block doors from opening when shields are in place; and 5. The signature and certification of a registered professional engineer or architect; c. Manufacturer's specification sheets if using manufactured measures, such as, for example, sealants; d. Manufacturer's catalog cuts if ordering measures, such as, for example, gates or shields, from a catalog; e. A statement of the wording of the directions for securing and releasing any gate or closure shield, which directions are required to appear on the back of any gate or closure shield; f. An emergency action plan that includes: 1. A description of where the floodproofing measures will be stored; 2. A description of who will be responsible for ensuring that the measures are in place, and who will monitor any closure shields, if the structure is an occupied structure; and 3. An annual schedule of when the floodproofing measures will be in use; g. A statement of the wording of notices to be posted in conspicuous locations on each floor of the structure, in such form, locations and numbers as are reasonably necessary to inform occupants of the structure that the structure is floodproofed and identifying the specific location of any floodproofing equipment requiring human operation in order for the floodproofing to be effective; h. A plan of the structure showing the location of the required floodproofing notices; and i. A plan for maintenance and inspection of the floodproofing measures. (4) A post-construction floodproofing certificate, signed and certified by a registered professional engineer or architect, accurately documenting the as-built elevation of the floodproofing improvements, must be submitted to the Utilities Executive Director and accepted before release of a certificate of occupancy for the structure.
(Ord. No. 37, 2005, 3-15-05; Ord. No. 080, 2011, § 1, 9-6-11; Ord. No. 161, 2013, §§ 5, 6, 11-19-13)
Ask a question about Fort Collins law
Corpus searches the Fort Collins sections it holds and shows the ones that match, with their citations. Free, no sign-in.
