§ 15.14.050 — Regulations—Flood fringe district (FF)

Municipal Code of the City of Loveland, Colorado (Codified through Ordinance No. 6832, enacted June 2, 2026. (Supp. No. 14)) · Loveland Municipal Code § 15.14.050

Corpus is an independent public-information project, not the official City of Loveland website. Stable reference: corpuslaw.us/code/791160a2-cfde-4c54-b10e-f10d2f53047a

15.14.050 - Regulations—Flood fringe district (FF).

A. Fill. The use of fill in the flood fringe district (FF) shall be the minimum necessary to comply with the provisions of this regulation. When required by the provisions of Title 18, fill in the FF district shall be to a point no lower than the regulatory flood protection elevation for the area in question. Such fill shall further extend at such elevation at least 15 feet beyond the extremities of any structure erected on such fill. No fill shall be used in such a manner as to restrict the flow capacity of any tributary or other drainageway to the main stream. B. Structures. 1. Any structure may be placed in the FF district only if the lowest floor level is at or above the regulatory flood protection elevation. Any new structure or addition to an existing structure on a property removed from the FF district by the issuance of a FEMA Letter of Map Revision Based on Fill ("LOMR-F") still must be constructed such that its lowest floor level is at or above the regulatory flood protection elevation. Nonresidential structures may be permitted without being placed on fill, provided the floodproofing requirements of Section 15.14.080 are met. 2. All utility services, furnaces, water heaters, and electrical wiring in connection with structures shall, wherever possible, be placed above the regulatory flood protection elevation or, where elevation is not practicable, shall be adequately floodproofed in a manner approved by the city building official. 3. If any structure or portions of any nonresidential structure are not constructed upon fill, the portion not on fill shall be floodproofed in a manner consistent with requirements for placing a structure in the FF district to an elevation equal to the regulatory flood protection elevation. 4. For all new construction and substantial improvements, fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria: a. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided; b. The bottom of all openings shall be no higher than one foot above the finished internal and external grade; and c. Openings may be equipped with screens, louvers, or other coverings or devices, provided they permit the automatic entry and exit of floodwaters. 5. Electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities shall be designed and located so as to prevent water from entering or accumulating within the components during conditions of flooding.

(Ord. 5717 § 3, 2012; Ord. 3441 § 11, 1987; Ord. 1708 § 1 (part), 1978)

Ask a question about Loveland law

Corpus searches the Loveland sections it holds and shows the ones that match, with their citations. Free, no sign-in.