For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.14.060 — Regulations—Areas of special flood hazard

Municipal Code of the City of Loveland, Colorado (Codified through Ordinance No. 6832, enacted June 2, 2026. (Supp. No. 14)) · Loveland Municipal Code § 15.14.060

Corpus is an independent public-information project, not the official City of Loveland website. Stable reference: corpuslaw.us/code/a21acf51-ef22-4646-807b-96aad0c56907

15.14.060 - Regulations—Areas of special flood hazard.

In all areas of special flood hazards, the following provisions are required: A. New construction and substantial improvement of any commercial, industrial, or other nonresidential structure shall either have the lowest floor, including basement, above the regulatory flood protection elevation, or, together with attendant utility and sanitary facilities, shall: 1. Be floodproofed so that below the regulatory flood protection elevation the structure is watertight with walls substantially impermeable to the passage of water; 2. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyance; and 3. Be certified by a registered professional engineer or architect that the standards of this section are satisfied. Such certification shall be provided to the building official. B. All manufactured homes and those to be substantially improved shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is at or above the regulatory flood protection elevation and shall be securely anchored to an adequately anchored foundation system by providing over-the-top ties and frame ties to ground anchors. Specific requirements shall include: (i) over-the-top ties at each of the four corners of the manufactured home, with two additional ties per side at intermediate locations (one additional tie per side at intermediate locations for manufactured homes less than fifty feet long); and (ii) frame ties at each corner of the home with five additional ties per side at intermediate points (four additional ties per side at intermediate points for manufactured homes less than 50 feet long). All additions to manufactured homes shall be similarly anchored. All components of the anchoring system shall be capable of carrying a force of 4,800 pounds. C. Located within areas of special flood hazard are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles, and erosion potential, the following provisions apply: 1. All encroachments, including fill, new construction, substantial improvements, and other development are prohibited unless certification by a registered professional engineer or architect is provided demonstrating that such encroachments will not result in any increase in flood levels during the occurrence of the base flood discharge; and 2. All new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions. D. All new and substantially improved critical facilities and new additions to critical facilities located within the areas of special flood hazard shall be regulated to a higher standard than structures not determined to be critical facilities. For the purposes of this chapter, protections shall include one of the following: (i) the structure shall be located outside of the areas of special flood hazard; or (ii) the structure's lowest floor level shall be elevated or floodproofed to at least two feet above the regulatory flood datum. New critical facilities shall, when practical as determined by the public works department stormwater division, have continuous non-inundated access (ingress and egress for evacuation and emergency services) during a 100-year flood event.

(Ord. 5717 § 4, 2012; Ord. 3441 § 12, 1987; Ord. 1708 § 1 (part), 1978)

Ask a question about Loveland law

Corpus searches the Loveland sections it holds and shows the ones that match, with their citations. Free, no sign-in.