§ 15.14.080 — Floodproofing
Municipal Code of the City of Loveland, Colorado (Codified through Ordinance No. 6832, enacted June 2, 2026. (Supp. No. 14)) · Loveland Municipal Code § 15.14.080
Corpus is an independent public-information project, not the official City of Loveland website. Stable reference: corpuslaw.us/code/2e105a11-25dd-49e2-b925-0e064a43a0b3
15.14.080 - Floodproofing.
Floodproofing measures taken for nonresidential structures pursuant to this chapter shall be designed consistent with the regulatory flood protection elevation for the particular area, flood velocities, durations, rate of rise, hydrostatic and hydrodynamic forces, and other factors associated with the regulatory flood. The building department shall require that the applicant submit a plan or document certified by a registered professional engineer or architect that the floodproofing measures are consistent with the regulatory flood protection elevation and associated flood factors for a particular area. The following floodproofing measures shall, as applicable, be required or taken in connection with specific construction. Such measures shall be undertaken in a manner consistent with requirements detailed by floodproofing regulations as published by the U.S. Army Corps of Engineers: A. Anchorage to resist flotation and lateral movement; B. Installation of watertight doors, bulkheads, and shutters, or reinforcement of walls to resist water pressures; C. Use of paints, membranes, or mortars to reduce seepage of water through walls; D. Addition of mass or weight to structures to resist flotation; E. Installation of pumps to lower water level in structures; F. Construction of water supply and waste treatment systems so as to prevent the entrance of floodwaters; G. Installation of pumping facilities or comparable practices for subsurface drainage systems for buildings to relieve external foundation wall and basement flood pressures; H. Construction to resist rupture or collapse caused by water pressure or floating debris; I. Installation of valves or controls on sanitary and storm drains which will permit the drain to be closed to prevent backup of sewage and storm waters into the building or structures; J. Location of all electrical equipment, lines, circuits, and installed electrical appliances in a manner which will assure they are not subject to flooding; K. Construction of water, sewer, and natural gas lines to resist rupture or collapse caused by water pressure; and L. Location of any structural storage facilities for chemical explosives, buoyant materials, flammable liquids, or other toxic materials which could be hazardous to public health, safety and welfare in a manner which will assure that the facilities are situated at elevations above the heights associated with the regulatory flood protection elevation or that the facilities are adequately floodproofed to prevent flotation of storage containers which could result in the escape of toxic materials into floodwaters.
(Ord. 5717 § 7, 2012; Ord. 1708 § 1 (part), 1978)
Ask a question about Loveland law
Corpus searches the Loveland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
